| Outdoor unit | Brand | SEER2 | HSPF2 | Heat at 5°F | Cold-climate pairings | Certified pairings |
|---|---|---|---|---|---|---|
5TWX7024A1 | Trane | 15.2–18 | 8–11 | 16,700–17,600 Btu/h | 214 | 241 |
5A6H7024A1 | American Standard | 15.2–17.1 | 8.1–11 | 16,700–17,700 Btu/h | 222 | 245 |
5TWR7024A1 | Trane | 15.2–17.1 | 8.1–11 | 16,700–17,700 Btu/h | 222 | 245 |
27VNA324A*030* | Carrier | 18–23 | 8.5–10.5 | 19,100–23,000 Btu/h | 430 | 430 |
293VAN024**AA* | Bryant | 18–23 | 8.5–10.5 | 19,100–23,000 Btu/h | 430 | 430 |
B5H3V24*K*AAA* | ACiQ, Airquest +7 more | 18–23 | 8.5–10.5 | 19,100–23,000 Btu/h | 3,771 | 3,771 |
SL22KLV-024-230A** | Lennox | 16.9–20.5 | 8.2–10.5 | 17,700–24,200 Btu/h | 102 | 107 |
37MUHAQ24AA3 | Bryant, Carrier +3 more | 16–18.7 | 9–10.5 | 19,100–21,600 Btu/h | 41 | 41 |
D5CUHAH24AAK | Airquest, Arcoaire +15 more | 16–18.7 | 9–10.5 | 19,100–21,600 Btu/h | 97 | 97 |
MOX430-24HFN10-M3X | MDV | 15.2–18.7 | 8.5–10.5 | 19,600–21,600 Btu/h | 71 | 71 |
ACIQ-24-HPD | ACiQ, 1HVAC | 16–18.6 | 8.9–10.5 | 19,600–21,600 Btu/h | 19 | 19 |
AUO19-24N2-M3H | AI Air Conditioning | 16–18.6 | 9.2–10.5 | 19,600–21,600 Btu/h | 6 | 6 |
CH-PQ24-230VO | Cooper&Hunter | 16–18.6 | 8.5–10.5 | 19,600–21,000 Btu/h | 8 | 8 |
CPH3-24CD(O) | ComfortStar | 17.5–18.6 | 10–10.5 | 19,600–21,600 Btu/h | 3 | 3 |
ML24HP230LMNTH-O | Mainline | 16–18.6 | 8.5–10.5 | 19,600–21,600 Btu/h | 20 | 20 |
MO1HE-H24B-2A | Midea | 15.2–18.6 | 8.5–10.5 | 19,600–21,600 Btu/h | 160 | 160 |
MSHMA24R2AN1 | MoovAir | 16–18.6 | 9.5–10.5 | 19,600–21,600 Btu/h | 6 | 6 |
SHV24H2BA | Innovair | 15.2–18.6 | 8.5–10.5 | 19,600–21,600 Btu/h | 44 | 44 |
DRU1H24S2A | DuraSTAR | 15.2–18.4 | 8.5–10.5 | 19,600–21,600 Btu/h | 53 | 53 |
A-VXP24SA-1 | Century, Comfort Aire +1 more | 16–18.3 | 9.5–10.5 | 19,600–21,600 Btu/h | 12 | 12 |
HHS-24HD-B | Multi MFG | 17.5–18.3 | 9.2–10.5 | 19,600–21,600 Btu/h | 3 | 3 |
DRU1U24S2A | DuraSTAR | 15.2–18.4 | 8.5–10.4 | 19,000–21,600 Btu/h | 53 | 53 |
MO1BE-H24B-2A | Midea | 15.2–18.4 | 8.5–10.4 | 19,000–21,600 Btu/h | 159 | 159 |
MOX430-24HFN10-M3 | MDV | 15.2–18.4 | 8.5–10.4 | 19,000–21,600 Btu/h | 71 | 71 |
SOV24H2BA | Innovair | 15.2–18.4 | 8.5–10.4 | 19,000–21,600 Btu/h | 44 | 44 |
37MURAQ24AA3 | Bryant, Carrier +3 more | 15.5–18.2 | 9–10.4 | 19,000–21,600 Btu/h | 31 | 31 |
D5CURAH24AAK | Airquest, Arcoaire +15 more | 15.5–18.2 | 9–10.4 | 19,000–21,600 Btu/h | 84 | 84 |
ACIQ-24-EHPD | ACiQ, 1HVAC | 16–18.1 | 8.9–10.4 | 19,000–21,600 Btu/h | 16 | 16 |
AUO18-24N2-M3 | AI Air Conditioning | 16–18.1 | 9–10.4 | 19,000–21,600 Btu/h | 5 | 5 |
CPR3-24CD(O) | ComfortStar | 17.4–18.1 | 9.7–10.4 | 19,600–21,600 Btu/h | 2 | 2 |
HES-24HD-B | Multi MFG | 16–18.1 | 9–10.4 | 19,000–21,600 Btu/h | 3 | 3 |
ML24HP230LMNT-O | Mainline | 16–18.1 | 8.5–10.4 | 19,000–21,600 Btu/h | 18 | 18 |
MSHEA24R2AN1 | MoovAir | 16–18.1 | 9–10.4 | 19,000–21,600 Btu/h | 3 | 3 |
ESHEA24R2AN1 | Elios | 16–17.4 | 9–10.4 | 19,000–19,600 Btu/h | 3 | 3 |
5A5V0X36A1 | American Standard | 20 | 10.3 | 35,600 Btu/h | 1 | 1 |
5TCV0X36A1 | Trane | 20 | 10.3 | 35,600 Btu/h | 1 | 1 |
A7CP21V24P-**A | Airease, Armstrong Air +1 more | 15.2–21 | 7.8–10.2 | 13,900–18,600 Btu/h | 197 | 391 |
EL21KLV-024-230A** | Lennox | 15.2–21 | 8.1–10.2 | 13,900–18,600 Btu/h | 94 | 178 |
NS21H24MA5-**A | GE | 15.2–20.5 | 8.2–10.2 | 13,900–18,600 Btu/h | 46 | 91 |
5A6V0X24A1 | American Standard | 18.4–22.4 | 9–10 | 16,800–18,200 Btu/h | 83 | 84 |
5TWV0X24A1 | Trane | 18.4–22.4 | 9–10 | 16,800–18,200 Btu/h | 83 | 84 |
FRP19AY24AJVC | Friedrich | 20–21 | 8.5–10 | 17,400–19,500 Btu/h | 53 | 59 |
RP19AY24AJVC | Rheem | 20–21 | 8.5–10 | 17,400–19,500 Btu/h | 27 | 32 |
UP19AY24AJVC | Ruud | 20–21 | 8.5–10 | 17,400–19,500 Btu/h | 35 | 40 |
AOH-24U3T24P | Hisense | 16–20 | 8.2–10 | 20,800–21,000 Btu/h | 3 | 3 |
AUWR-2424P | Hisense | 16–20 | 8.2–10 | 20,800–21,000 Btu/h | 3 | 3 |
AUWR-24U3TK5 | Hisense | 20 | 10 | 20,800 Btu/h | 1 | 1 |
GRID24OC | Gridless | 16–20 | 8.2–10 | 20,800–21,000 Btu/h | 2 | 2 |
HBEFU-24R454B | Endura | 16–20 | 8.2–10 | 20,800–21,000 Btu/h | 2 | 2 |
HVHDZ-24V2D | Haxxair | 16–20 | 8.2–10 | 20,800–21,000 Btu/h | 2 | 2 |
MSD-24HD-B | Multi MFG | 20 | 10 | 20,800 Btu/h | 1 | 1 |
SM-24HSM2-CU | Sum X | 16–20 | 8.2–10 | 20,800–21,000 Btu/h | 2 | 2 |
VAUWR-24HCDR2 | Voltas | 16–20 | 8.2–10 | 20,800–21,000 Btu/h | 2 | 2 |
ZE-624HPA | Zephyr | 16–20 | 8.2–10 | 20,800–21,000 Btu/h | 3 | 3 |
249VAN024**AA* | Bryant | 15.2–19.5 | 8–10 | 20,000–22,200 Btu/h | 1,139 | 1,147 |
27VPA924A*030* | Carrier | 15.2–19.5 | 8–10 | 20,000–22,200 Btu/h | 1,212 | 1,222 |
N5H9V24*K*AAA* | Airquest, Arcoaire +6 more | 15.2–19.5 | 8–10 | 20,000–22,200 Btu/h | 8,656 | 8,720 |
Q5H9V24*K*AAA* | Airquest, Arcoaire +5 more | 15.2–19.5 | 8–10 | 20,000–22,200 Btu/h | 7,595 | 7,651 |
RD18AY24AJVC | Friedrich, Rheem +3 more | 17–19 | 8.1–10 | 16,800–18,400 Btu/h | 397 | 399 |
BOHA-24MTB-M18S | Bosch | 15.2–18.9 | 8.4–10 | 16,800–34,000 Btu/h | 15 | 15 |
AHU3G-24HFN-B | AproDr, ApooDr | 17.5–18.6 | 9.2–10 | 20,000–20,600 Btu/h | 3 | 3 |
BMSAH24HHC | Blueridge | 18.3–18.6 | 10 | 20,600–21,600 Btu/h | 2 | 2 |
BNG3A24UCN | Blueridge | 16–18.6 | 9.5–10 | 20,600–21,600 Btu/h | 4 | 4 |
BZ33-INV24OUT2-454-G3-J | Breeze33 | 16–18.6 | 9.5–10 | 20,600–21,600 Btu/h | 4 | 4 |
KEENHYDHP24AA | KEEN Home | 17.5–18.6 | 9.2–10 | 20,000–21,600 Btu/h | 3 | 3 |
KOB-HH-UUX24HP-2AAMA | Kaden | 18.3–18.6 | 10 | 20,600–21,600 Btu/h | 2 | 2 |
LEA24CEN36-O | Novair | 15.3–18.6 | 9–10 | 20,000–21,600 Btu/h | 8 | 8 |
SPHP-Z-V024BB | AC Pro | 16–18.6 | 8.9–10 | 20,000–21,600 Btu/h | 6 | 6 |
UHO24-NB-LA-Q | Mitsutomo | 16–18.6 | 9.5–10 | 20,600–21,600 Btu/h | 4 | 4 |
UHP18024-O | MRCOOL | 16–18.6 | 8.9–10 | 20,000–20,600 Btu/h | 10 | 10 |
1U24T3PS*HE | Haier | 15.2–18.5 | 8.5–10 | 20,000–23,400 Btu/h | 119 | 119 |
7SCP18V24P-**A | Allied, Concord +1 more | 15.2–18.5 | 8.5–10 | 20,000–23,400 Btu/h | 390 | 390 |
A7SCP18V24P-**A | Airease, Armstrong Air | 15.2–18.5 | 8.5–10 | 20,000–23,400 Btu/h | 268 | 268 |
EL18KSLV-024-230A** | Lennox | 15.2–18.5 | 8.5–10 | 20,000–23,400 Btu/h | 205 | 205 |
MDV-V24WMN10T | Midea | 16–18.5 | 8.5–10 | 19,200–20,000 Btu/h | 9 | 9 |
MDV-V24WMN10T(B) | Midea | 15.2–18.5 | 8.4–10 | 16,800–20,000 Btu/h | 14 | 14 |
NS18H24HA5*** | GE Appliances | 15.2–18.5 | 8.5–10 | 20,000–23,400 Btu/h | 221 | 221 |
CENTRAL-24-HP-C-230B00-O | MRCOOL | 15.8–18.4 | 8.5–10 | 20,000–21,600 Btu/h | 52 | 52 |
EZ-24-HPB | 1HVAC, Diycool +2 more | 18.4 | 10 | 21,600 Btu/h | 4 | 4 |
4CDH2024C21 | CanAir | 16–18.3 | 9.5–10 | 21,000–21,600 Btu/h | 3 | 3 |
A-KX12P24SA-1 | Kerr Kapstone | 16–18.3 | 9.5–10 | 21,000–21,600 Btu/h | 3 | 3 |
A-KXP24SA-1 | KERR | 16–18.3 | 9.5–10 | 21,000–21,600 Btu/h | 5 | 5 |
A-VXP24TA-1 | Comfort-Aire | 16–18.3 | 9.5–10 | 21,000–21,600 Btu/h | 3 | 3 |
AA24H/O64P | Trust Air Conditioners | 16–18.3 | 9.2–10 | 20,000–21,600 Btu/h | 4 | 4 |
CCB1-H24A-O | Capella | 15.3–18.3 | 9–10 | 20,000–21,600 Btu/h | 7 | 7 |
CCOXHB24V24HP | Custom Comfort | 16–18.3 | 9.5–10 | 21,000–21,600 Btu/h | 3 | 3 |
CU-HM24BAHU | Panasonic | 16–18.3 | 9–10 | 20,000–21,600 Btu/h | 9 | 9 |
DIRM4-24MAGICPRO20-OU | Direct Air | 16–18.3 | 9.2–10 | 20,000–21,600 Btu/h | 5 | 5 |
ECUO-24H | Eco-air | 15.8–18.3 | 8.5–10 | 20,000–21,600 Btu/h | 25 | 25 |
ESCA17H-24ABA | Ecoer | 18.3 | 10 | 21,600 Btu/h | 1 | 1 |
ESHMA24R2AN1 | Elios | 16–18.3 | 9.5–10 | 21,000–21,600 Btu/h | 3 | 3 |
MAMOX430-24HFN10-M3X | Mits Air | 16–18.3 | 9.5–10 | 21,000–21,600 Btu/h | 3 | 3 |
ODUMOX430-24HFN10-M3X | Kepler | 16–18.3 | 9.5–10 | 21,000–21,600 Btu/h | 5 | 5 |
SDB1-H24A-O | Stelpro | 15.3–18.3 | 9–10 | 20,000–21,600 Btu/h | 7 | 7 |
SENDC-24HF-OG | Senville | 16–18.3 | 9.5–10 | 21,000–21,600 Btu/h | 2 | 2 |
SHC24AH224V | SlimAir | 18.3 | 10 | 21,600 Btu/h | 1 | 1 |
W5H9V24AKAAA | Grandaire | 16–18.3 | 9.5–10 | 21,000–21,600 Btu/h | 3 | 3 |
WDHP-24HH | Wells | 16–18.3 | 9.5–10 | 21,000–21,600 Btu/h | 3 | 3 |
ZSOVA-24HDMB-USHH | ZERO | 18.3 | 10 | 21,600 Btu/h | 1 | 1 |
HHS-25HD-B | Multi MFG | 17–17.5 | 9.4–10 | 27,000–28,000 Btu/h | 2 | 3 |
TZID24H520ZCS | Thermal Zone | 15.2–18.4 | 8.5–9.9 | 19,000–21,600 Btu/h | 56 | 56 |
AH24H/O64P | Trust Air Conditioners | 16–18.1 | 9–9.7 | 19,000–21,600 Btu/h | 4 | 4 |
AHU19-24HN1-C | ApooDr, AproDr | 18.1 | 9.7 | 21,600 Btu/h | 2 | 2 |
BMSAHS2418C | Blueridge | 18.1 | 9.7 | 21,600 Btu/h | 1 | 1 |
BNG2A24SCN | Blueridge | 16–18.1 | 9–9.7 | 19,000–21,600 Btu/h | 3 | 3 |
CU-M24BAHU | Panasonic | 16–18.1 | 9–9.7 | 19,000–21,600 Btu/h | 9 | 9 |
DIRM4-24CS19-OU | Direct Air | 16–18.1 | 9–9.7 | 19,000–21,600 Btu/h | 5 | 5 |
ECUO-24E | Eco-air | 15.8–18.1 | 8.5–9.7 | 19,000–21,600 Btu/h | 25 | 25 |
ESCA16H-24BBA | Ecoer | 18.1 | 9.7 | 21,600 Btu/h | 1 | 1 |
EZ-24-EHPB | 1HVAC, Diycool +2 more | 18.1 | 9.7 | 21,600 Btu/h | 4 | 4 |
EZCENO24K | NG Trade | 18.1 | 9.7 | 21,600 Btu/h | 1 | 1 |
KEENSTDHP24AA | KEEN Home | 16–18.1 | 9–9.7 | 19,000–21,600 Btu/h | 2 | 2 |
KOB-UUX24HP-2AAMA | Kaden | 18.1 | 9.7 | 21,600 Btu/h | 1 | 1 |
MVP-24-HP-C-230A00-O | MRCOOL | 15.8–18.1 | 8.5–9.7 | 19,000–21,600 Btu/h | 51 | 51 |
ODUMOX430-24HFN10-M3 | Kepler | 16–18.1 | 9–9.7 | 19,000–21,600 Btu/h | 5 | 5 |
RHO24-NB-LA-Q | Mitsutomo | 16–18.1 | 9–9.7 | 19,000–21,600 Btu/h | 3 | 3 |
SAK-24FDN2-M18M | Star Air Kontrol | 18.1 | 9.7 | 21,600 Btu/h | 1 | 1 |
SHC24AE224V | SlimAir | 18.1 | 9.7 | 21,600 Btu/h | 1 | 1 |
SPHP-Y-V024BB | AC Pro | 16–18.1 | 8.9–9.7 | 19,000–21,600 Btu/h | 7 | 7 |
W5H8V24AKAAA | Grandaire | 16–18.1 | 9–9.7 | 19,000–21,600 Btu/h | 3 | 3 |
ZSOVA-24HDMB-US | ZERO | 18.1 | 9.7 | 21,600 Btu/h | 1 | 1 |
MSHMA24R2AN* | MoovAir | 16–16.4 | 9.5–9.6 | 21,000 Btu/h | 3 | 3 |
MLP19AY24AJVC | Mainline | 20–21 | 8.5–9.5 | 18,400–19,500 Btu/h | 27 | 27 |
SP19AY24AJVC | Russell, Sure | 20–21 | 8.5–9.5 | 17,400–19,500 Btu/h | 54 | 65 |
FOP1924MJAYCA | Fujitsu | 20 | 8.5–9.5 | 18,400–19,500 Btu/h | 1 | 2 |
MHPA-24DCTO | MDX | 20 | 9.5 | 17,800 Btu/h | 1 | 1 |
MYUA24NA23BCH20-O | Bestcold | 20 | 9.5 | 17,800 Btu/h | 1 | 1 |
UCHA-24HDCT | UTL, VKIN | 20 | 9.5 | 17,800 Btu/h | 2 | 2 |
UCHA-24HDCT* | UTL | 20 | 9.5 | 17,800 Btu/h | 1 | 1 |
VHP-UCA-24HDC-A | VillaTherm | 20 | 9.5 | 17,800 Btu/h | 1 | 1 |
VHP-UCHA-24HDCT | VillaTherm | 20 | 9.5 | 17,800 Btu/h | 1 | 1 |
HH824E2S11 | Coleman, Luxaire +4 more | 15.2–19 | 8.5–9.5 | 17,000–19,400 Btu/h | 1,155 | 1,841 |
FA-H24-VKCE/OD-454 | ForestAir | 18.5 | 9.5 | 24,000 Btu/h | 2 | 2 |
MCHA-24HDCSO2 | MDX | 18.5 | 9.5 | 24,000 Btu/h | 1 | 1 |
UCHA-24HDCSN4 | UTL, VKIN | 18.5 | 9.5 | 24,000 Btu/h | 4 | 4 |
VHPSD-UCHA-24HDCSN4 | VillaTherm | 18.5 | 9.5 | 24,000 Btu/h | 3 | 3 |
37MUHAQ24AA3+KSAIC0701230 | Carrier, Bryant +2 more | 15.2–18 | 8.1–9.5 | 18,700–20,600 Btu/h | 1,831 | 1,831 |
BOHA-24RTB-M18S | Bosch | 15.5–18 | 8.1–9.5 | 16,800–20,000 Btu/h | 12 | 12 |
D5CUHAH24AAK+KSAIC0701230 | Airquest, Smart Comfort +7 more | 15.2–18 | 8.1–9.5 | 18,700–20,600 Btu/h | 4,017 | 4,017 |
MDV-V24WMN10T(A) | Midea | 15.5–18 | 8.1–9.5 | 16,800–20,000 Btu/h | 11 | 11 |
UCHA-24HFDCSN4 | UTL | 17.8 | 9.5 | 18,000 Btu/h | 1 | 1 |
37MUHAQ24AA3+TIC2025-0016 | Bryant, Carrier +1 more | 17.5 | 9.5 | 19,000 Btu/h | 3 | 3 |
D5CUHAH24AAK+TIC2025-0016 | Airquest, Arcoaire +6 more | 17.5 | 9.5 | 19,000 Btu/h | 8 | 8 |
P30-24CENHP-R454 | Proair | 16–17.2 | 8.5–9.5 | 20,000–21,000 Btu/h | 4 | 4 |
FRP17AY24AJVC | Friedrich | 16–17 | 8.1–9.5 | 16,100–18,400 Btu/h | 87 | 88 |
H24TDHXPC | TCL | 17 | 9.5 | 24,000 Btu/h | 1 | 1 |
RP17AY24AJVC | Rheem, Ruud | 16–17 | 8.1–9.5 | 16,100–18,400 Btu/h | 89 | 92 |
SP17AY24AJVC | Sure | 16–17 | 8.1–9.5 | 16,100–18,400 Btu/h | 43 | 45 |
THH24TEI2NAG0F24 | TCL | 17 | 9.5 | 24,000 Btu/h | 1 | 1 |
37MURAQ24AA3+KSAIC0701230 | Carrier, Bryant +2 more | 15.2–16 | 8.5–9.5 | 19,000–20,200 Btu/h | 488 | 488 |
A-KXP24TA-1 | KERR | 16 | 9.5 | 21,000 Btu/h | 2 | 2 |
D5CURAH24AAK+KSAIC0701230 | Airquest, Arcoaire +7 more | 15.2–16 | 8.5–9.5 | 19,000–20,200 Btu/h | 1,018 | 1,018 |
ESHMA24R2AN* | Elios | 16 | 9.5 | 21,000 Btu/h | 2 | 2 |
DOT-D24HNR8-EA01(J0) | Duohome | 20 | 9.4 | 20,000 Btu/h | 1 | 1 |
5HPL6024A1000A* | Trane/American Standard | 19.5 | 9.4 | 14,000 Btu/h | 0 | 1 |
HP-24ODU-001 | Jetson | 17 | 9.2 | 20,000 Btu/h | 2 | 2 |
EL19KPV-024-230A** | Lennox | 15.2–20 | 7.8–9 | 11,700–17,000 Btu/h | 0 | 221 |
B5H0V24*K*AAA* | ACiQ, Kenmore +7 more | 15.5–19 | 8.5–9 | 16,100–17,300 Btu/h | 179 | 284 |
(C,H,T)5H0V24*K*AAA* | Kenmore | 15.5–18 | 8.5–9 | 16,300–17,300 Btu/h | 103 | 103 |
048-T-24K-ODU-T | Della | 18 | 9 | 18,000 Btu/h | 1 | 1 |
27VNA024A*030* | Carrier | 15.5–18 | 8.5–9 | 16,300–17,300 Btu/h | 104 | 104 |
290VAN024**AA* | Bryant | 15.5–18 | 8.5–9 | 16,300–17,300 Btu/h | 104 | 104 |
AOH-24T3T25U | Hisense | 18 | 9 | 18,000 Btu/h | 1 | 1 |
AOH-24U3T25U | Hisense | 18 | 9 | 18,000 Btu/h | 2 | 2 |
AUWR-24U3TJ3 | Hisense | 18 | 9 | 18,000 Btu/h | 1 | 1 |
BOVA-24RXB-M15S | Bosch | 15.2–18 | 8.5–9 | 12,800–17,200 Btu/h | 20 | 20 |
BOVB-24RTB-M15S | Bosch | 15.2–18 | 8.5–9 | 12,800–17,200 Btu/h | 26 | 26 |
C5H0V24*K*AAA* | Comfortmaker, Day & Night +1 more | 15.5–18 | 8.5–9 | 16,300–17,300 Btu/h | 312 | 312 |
H5H0V24*K*AAA* | ACiQ, Airquest +2 more | 15.5–18 | 8.5–9 | 16,300–17,300 Btu/h | 416 | 416 |
HOC24B | Hessaire | 18 | 9 | 18,000 Btu/h | 1 | 1 |
MOVB-24HDN10-M16G | Midea | 15.2–18 | 8.5–9 | 12,800–17,200 Btu/h | 24 | 24 |
MOVC-24HDN10-M16G | Midea | 15.2–18 | 8.5–9 | 12,800–17,200 Btu/h | 32 | 32 |
T5H0V24*K*AAA* | Tempstar | 15.5–18 | 8.5–9 | 16,300–17,300 Btu/h | 104 | 104 |
THH24TEI2NAI0H24 | TCL | 18 | 9 | 18,000 Btu/h | 1 | 1 |
WFPU17Y243D | Friedrich | 18 | 9 | 18,000 Btu/h | 1 | 1 |
ZOV-24HDTB | ZERO | 18 | 9 | 18,000 Btu/h | 1 | 1 |
P25-24CENHP-R454 | Proair | 16–17.2 | 8.5–9 | 19,000–20,000 Btu/h | 4 | 4 |
ESHEA24R2AN* | Elios | 16 | 9 | 19,000 Btu/h | 3 | 3 |
MSHEA24R2AN* | MoovAir | 16 | 9 | 19,000 Btu/h | 1 | 1 |
WSCHV0024BA1-C | Continental | 16 | 9 | 19,000 Btu/h | 2 | 2 |
WSCHV0024BA1-N | Napoleon | 16 | 9 | 19,000 Btu/h | 2 | 2 |
5HPL9024A1000A* | Trane/American Standard | 19.2 | 8.9 | 11,500 Btu/h | 0 | 1 |
QS15H24HA5*** | Haier | 15.2–17.5 | 8.1–8.9 | 17,900–18,900 Btu/h | 118 | 118 |
7SHP15V24P-**A | Concord, Ducane +1 more | 15.2–16.9 | 8.1–8.9 | 17,900–18,900 Btu/h | 155 | 155 |
NS15H24HA5*** | GE Appliances | 15.2–16.9 | 8.1–8.9 | 17,900–18,900 Btu/h | 118 | 118 |
ML15KSPV-024-230A** | Lennox | 15.2–16.8 | 8.1–8.9 | 17,900–18,900 Btu/h | 110 | 110 |
5HCL9024A1000A* | Trane/American Standard | 19.7 | 8.8 | 26,000 Btu/h | 1 | 1 |
MO1AE-H24B-2A | Midea | 16.5 | 8.8 | 16,300 Btu/h | 1 | 1 |
MOX330-24HFN10-M3 | MDV | 16.4–16.5 | 8.7–8.8 | 16,300 Btu/h | 2 | 2 |
NAZ17V3622A1 | Navien, Inc. | 16.3–19.5 | 8.1–8.8 | 18,500–25,000 Btu/h | 0 | 12 |
A5H7V24AKAA | Airevantage | 16.4 | 8.7 | 16,300 Btu/h | 1 | 1 |
AE24H/O64P | Trust Air Conditioners | 16.4 | 8.7 | 16,300 Btu/h | 1 | 1 |
BNG1A24SCN | Blueridge | 16.4 | 8.7 | 16,300 Btu/h | 1 | 1 |
CH-ALT24HP24V-230VO | Cooper&Hunter | 16.4 | 8.7 | 16,300 Btu/h | 1 | 1 |
5HCL6024A1000A* | Trane/American Standard | 18.6 | 8.6 | 23,000 Btu/h | 1 | 1 |
7HP19V36P-**A | Allied, Concord +2 more | 15.2–20 | 7.8–8.5 | 12,100–17,700 Btu/h | 0 | 727 |
A7HP19V36P-**A | Airease, Armstrong Air | 15.2–20 | 7.8–8.5 | 12,100–17,700 Btu/h | 0 | 404 |
BH719M36P-**A | AC Pro, Blueridge +1 more | 15.2–20 | 7.8–8.5 | 13,600–17,000 Btu/h | 0 | 444 |
HSA1936V1-**A | Century, Comfort-Aire | 15.2–20 | 7.8–8.5 | 13,700–17,000 Btu/h | 0 | 142 |
NS19H36MA5-**A | GE | 15.2–20 | 7.8–8.5 | 13,700–17,700 Btu/h | 0 | 152 |
H24TDH17XAC | TCL | 18–19 | 8.5 | 18,000–19,000 Btu/h | 2 | 2 |
(C,H,T)5H8T24*K*AAA* | Kenmore | 15.2–18.5 | 7.8–8.5 | 10,700–11,500 Btu/h | 0 | 496 |
248TAN024**AA* | Bryant | 15.2–18.5 | 7.8–8.5 | 10,700–11,500 Btu/h | 0 | 552 |
27TPA824A**30* | Carrier | 15.2–18.5 | 7.8–8.5 | 10,700–11,500 Btu/h | 0 | 591 |
C5H8T24*K*AAA* | Comfortmaker, Day & Night +1 more | 15.2–18.5 | 7.8–8.5 | 10,700–11,500 Btu/h | 0 | 1,530 |
GH8TAN524**AA* | Carrier, Bryant | 15.2–18.5 | 7.8–8.5 | 10,700–11,500 Btu/h | 0 | 1,143 |
H5H8T24*K*AAA* | Airquest, Arcoaire +1 more | 15.2–18.5 | 7.8–8.5 | 10,700–11,500 Btu/h | 0 | 1,530 |
N5H8T24*K*AAA* | Airquest, Arcoaire +8 more | 15.2–18.5 | 7.8–8.5 | 10,700–11,500 Btu/h | 0 | 4,916 |
PH8TAN524**AA* | Bryant, Brock +2 more | 15.2–18.5 | 7.8–8.5 | 10,700–11,500 Btu/h | 0 | 1,162 |
PH8TAN524**AB* | Weathermaker | 15.2–18.5 | 7.8–8.5 | 10,700–11,400 Btu/h | 0 | 197 |
T5H8T24*K*AAA* | Tempstar | 15.2–18.5 | 7.8–8.5 | 10,700–11,500 Btu/h | 0 | 510 |
5A6V8X24A1 | American Standard | 18.1 | 8.5 | 17,600–18,700 Btu/h | 80 | 80 |
5TWV8X24A1 | Trane | 18.1 | 8.5 | 17,600–18,700 Btu/h | 80 | 80 |
BOVA-36RXB-M15S | Bosch | 15.2–18 | 8.5 | 17,500–21,000 Btu/h | 5 | 5 |
BOVB-36RTB-M15S | Bosch | 15.2–18 | 8.5 | 17,500–21,000 Btu/h | 5 | 5 |
HH824E2S12 | Coleman, Luxaire +3 more | 16–18 | 8.1–8.5 | 17,200–18,700 Btu/h | 1,215 | 1,443 |
MOVB-36HDN10-M16G | Midea | 15.2–18 | 8.5 | 17,500–21,000 Btu/h | 6 | 6 |
MOVC-36HDN10-M16G | Midea | 15.2–18 | 8.5 | 17,500–21,000 Btu/h | 6 | 6 |
XD524E2D11 | Champion, Coleman +2 more | 15.2–18 | 8.5 | 16,800–17,200 Btu/h | 24 | 24 |
XD536E2D11 | Champion, Coleman +2 more | 15.2–18 | 8.5 | 17,500–17,600 Btu/h | 8 | 8 |
YD524E2D11 | York | 15.2–18 | 8.5 | 16,800–17,200 Btu/h | 6 | 6 |
YD536E2D11 | York | 15.2–18 | 8.5 | 17,500–17,600 Btu/h | 2 | 2 |
AC024FCUPCG | Samsung | 16–17 | 8.5 | 23,000–23,800 Btu/h | 5 | 5 |
(C,H,T)5H6S24*K*AAA* | Kenmore | 15.2–16.5 | 7.8–8.5 | 10,800–11,900 Btu/h | 0 | 193 |
235SAN024**AA* | Bryant | 15.2–16.5 | 7.8–8.5 | 10,800–11,900 Btu/h | 0 | 210 |
246SAN024**AA* | Bryant | 15.2–16.5 | 7.8–8.5 | 10,800–11,900 Btu/h | 0 | 210 |
27SCA524A**30* | Carrier | 15.2–16.5 | 7.8–8.5 | 10,800–11,900 Btu/h | 0 | 217 |
27SPA624A**30* | Carrier | 15.2–16.5 | 7.8–8.5 | 10,800–11,900 Btu/h | 0 | 217 |
B5H6S24*K*AAA* | Airquest, Arcoaire +6 more | 15.2–16.5 | 7.8–8.5 | 10,800–11,900 Btu/h | 0 | 1,533 |
C5H6S24*K*AAA* | Comfortmaker, Day & Night +1 more | 15.2–16.5 | 7.8–8.5 | 10,800–11,900 Btu/h | 0 | 579 |
GH5SAN524**AA* | Carrier, Bryant | 15.2–16.5 | 7.8–8.5 | 10,800–11,900 Btu/h | 0 | 427 |
H5H6S24*K*AAA* | Airquest, Arcoaire +1 more | 15.2–16.5 | 7.8–8.5 | 10,800–11,900 Btu/h | 0 | 579 |
N5H5S24*K*AAA* | Airquest, Arcoaire +9 more | 15.2–16.5 | 7.8–8.5 | 10,800–11,900 Btu/h | 0 | 2,073 |
PH5SAN524**AA* | Bryant, Payne +2 more | 15.2–16.5 | 7.8–8.5 | 10,800–11,900 Btu/h | 0 | 562 |
PH5SAN524**AB* | Weathermaker | 15.2–16.5 | 7.8–8.5 | 10,800–11,900 Btu/h | 0 | 125 |
R5H5S24*K*AAA* | Airquest, Arcoaire +9 more | 15.2–16.5 | 7.8–8.5 | 10,800–11,900 Btu/h | 0 | 2,076 |
T5H6S24*K*AAA* | Tempstar | 15.2–16.5 | 7.8–8.5 | 10,800–11,900 Btu/h | 0 | 193 |
W5H5S24*K*AAA* | Ecotemp, Grandaire | 15.2–16.5 | 7.8–8.5 | 10,800–11,900 Btu/h | 0 | 170 |
RD16AY24AJVC | Friedrich, Rheem +3 more | 16 | 8.1–8.5 | 12,400–13,600 Btu/h | 48 | 58 |
MDV-V24WMN10T-H | Midea | 15.3 | 8.5 | 19,400 Btu/h | 1 | 1 |
ML16KP2-024-230A** | Lennox | 16–17.5 | 7.8–8.2 | 9,900–11,100 Btu/h | 0 | 71 |
7HP14F24P-**A | Allied, Concord +2 more | 15.2–16 | 7.8–8.2 | 10,500–11,600 Btu/h | 0 | 462 |
A7HP14F24P-**A | Airease, Armstrong Air | 15.2–16 | 7.8–8.2 | 10,500–11,600 Btu/h | 0 | 264 |
AC024FCUDCG | Samsung | 16 | 8.2 | 24,400 Btu/h | 1 | 1 |
BH714S24P-**A | AC Pro, Blueridge +1 more | 15.2–16 | 7.8–8.2 | 10,500–11,600 Btu/h | 0 | 270 |
EL16KP1-024-230A** | Lennox | 15.2–16 | 7.8–8.2 | 10,500–11,600 Btu/h | 0 | 179 |
HSA1424S1-**A | Century, Comfort-Aire | 15.2–16 | 7.8–8.2 | 10,600–11,600 Btu/h | 0 | 98 |
ML14KP1-024-230A** | Lennox | 15.2–16 | 7.8–8.2 | 10,500–11,600 Btu/h | 0 | 179 |
NS16H24SA5-**A | GE | 15.2–16 | 7.8–8.2 | 10,500–11,600 Btu/h | 0 | 99 |
W5H8T24*K*AAA* | Ecotemp, Grandaire | 15.2–18.5 | 7.8–8.1 | 10,700–11,400 Btu/h | 0 | 260 |
5A6H6024A1 | American Standard | 15.2–17 | 7.8–8.1 | 11,000–11,500 Btu/h | 0 | 126 |
5TWR6024A1 | Trane | 15.2–17 | 7.8–8.1 | 11,000–11,500 Btu/h | 0 | 126 |
5TWX6024A1 | Trane | 15.2–17 | 7.8–8.1 | 11,000–11,500 Btu/h | 0 | 93 |
5A6H5024A1 | American Standard | 15.2–16.5 | 7.8–8.1 | 10,900–11,400 Btu/h | 0 | 30 |
5TWR5024A1 | Trane | 15.2–16.5 | 7.8–8.1 | 10,900–11,400 Btu/h | 0 | 30 |
5TWX5024A1 | Trane | 15.2–16.5 | 7.8–8.1 | 10,600–11,700 Btu/h | 0 | 75 |
5HPL5024A1 | American Standard, Trane | 15.2–16 | 8.1 | 18,000–19,000 Btu/h | 60 | 60 |
5HPL5024A1000AA | American Standard, Trane | 16 | 8.1 | 18,000 Btu/h | 2 | 2 |
A5HL5024A1 | Ameristar, RunTru | 15.2–16 | 8.1 | 18,000–19,000 Btu/h | 40 | 40 |
A5HL5024A1000AA | Ameristar, RunTru | 16 | 8.1 | 18,000 Btu/h | 2 | 2 |
A5HP5024A1 | Ameristar, RunTru | 15.2–16 | 7.8–8.1 | 10,600–11,800 Btu/h | 0 | 72 |
N5HP5024A1 | American Standard, Trane | 15.2–16 | 7.8–8.1 | 10,900–11,600 Btu/h | 0 | 162 |
THH24HES2NAGOH24 | TCL | 15.2–16 | 8.1 | 18,000–19,000 Btu/h | 78 | 78 |
XH524E2S11 | Champion, Coleman +3 more | 15.2–16 | 7.8–8.1 | 11,200–12,700 Btu/h | 0 | 250 |
XH624E2S11 | Coleman, Luxaire +5 more | 15.2–16 | 7.8–8.1 | 11,900–12,800 Btu/h | 0 | 870 |
YH524E2S11 | York | 15.2–16 | 7.8–8.1 | 11,200–12,700 Btu/h | 0 | 55 |
YH624E2S11 | York | 15.2–16 | 7.8–8.1 | 11,900–12,800 Btu/h | 0 | 170 |
FSH4BF5M2SX24K | Frigidaire, Gibson | 16 | 7.8–8 | 11,000 Btu/h | 0 | 4 |
PSH4BF5M2SX24K | Maytag | 16 | 7.8–8 | 11,000 Btu/h | 0 | 2 |
SH4BF5M2SX24K | Nordyne, Nortek Global Hvac Llc | 16 | 7.8–8 | 11,000 Btu/h | 0 | 5 |
DRHP15B24AJ2AN | DuraSTAR | 15.2 | 7.8 | 11,200 Btu/h | 0 | 2 |
FOP1524TJAYNA | Fujitsu | 15.2 | 7.8 | — | 0 | 1 |
FRP15AY24AJ2N | Friedrich | 15.2 | 7.8 | 10,900–11,200 Btu/h | 0 | 6 |
FWP15AY24AJ2N | Friedrich | 15.2 | 7.8 | 10,900–11,100 Btu/h | 0 | 5 |
J5HP5024A1000AA | Oxbox | 15.2 | 7.8 | 10,000–10,200 Btu/h | 0 | 4 |
KOVH-24BAM152L | Kaden | 15.2 | 7.8 | 10,000–10,200 Btu/h | 0 | 6 |
MOVA-24HN10-M152L | Midea | 15.2 | 7.8 | 9,800–10,200 Btu/h | 0 | 14 |
MOVC-24HN10-M152L | Midea | 15.2 | 7.8 | 9,800–10,200 Btu/h | 0 | 14 |
RP15AY24AJ2N | Ruud, Rheem | 15.2 | 7.8 | 10,900–11,200 Btu/h | 0 | 10 |
SP15AY24AJ2N | Russell, Sure | 15.2 | 7.8 | 10,900–11,200 Btu/h | 0 | 8 |
SPHP-M-1024BB | AC Pro | 15.2 | 7.8 | 10,000–10,200 Btu/h | 0 | 7 |
WLP15AY24AJ2N | Whirlpool | 15.2 | 7.8 | 10,900 Btu/h | 0 | 1 |
WP15AY24AJ2N | Rheem, Ruud +2 more | 15.2 | 7.8 | 10,900–11,200 Btu/h | 0 | 11 |
Same size, other refrigerants: R-32 (58) · R-410A (159). Nearby sizes: 1.5-ton · 2.5-ton · 3-ton.
Size class is based on the median rated cooling capacity of each unit's certified pairings. Ranges show the spread across pairings, because the indoor unit changes the rating. A load calculation by your installer decides the right size.
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.