Refrigerant Finder
NG Trade · ENERGY STAR data November 12, 2026

NG Trade heat pump refrigerants: R-454B / R-32 / R-410A

NG Trade has 30 ENERGY STAR certified outdoor unit models (19 R-454B, 3 R-32, 8 R-410A) in 45 certified systems.

R-454B 19 (63%)R-32 3 (10%)R-410A 8 (27%)
Main refrigerant
R-454B
Outdoor models
30
Ducted / mini / packaged
5 / 25 / 0
Certified systems
45

Which refrigerant a NG Trade system uses depends on the exact outdoor model, not the brand. Check the model below or in the lookup, and make sure the indoor coil or air handler on your quote is certified with it.

NG Trade R-454B outdoor units

Outdoor unitTypeSizeSEER2HSPF2Heat at 5°FCertified pairings
OMSTAR091EMini/multi-split9,000 Btu24.6138,200 Btu/h1
OMSTAR121EMini/multi-split12,000 Btu23.111.58,600 Btu/h1
OMSTAR181EMini/multi-split18,000 Btu2411.113,000 Btu/h1
MOBMH480DMini/multi-split42,000 Btu20.4–21.310–10.636,000–38,000 Btu/h3
OMSTAR120EMini/multi-split12,000 Btu23.210.47,300 Btu/h1
OMSTAR241EMini/multi-split24,000 Btu23.51017,800 Btu/h1
MOBMH360DMini/multi-split36,000 Btu20–23.19.2–1026,000 Btu/h3
MOBMH180DMini/multi-split18,000 Btu20–231013,500–14,600 Btu/h3
EZCENO24KDucted2-ton18.19.721,600 Btu/h1
MOBMH270DMini/multi-split24,000 Btu21–239–9.518,800–19,000 Btu/h3
OBMH091BMini/multi-split9,000 Btu21.69.47,000 Btu/h1
OBMH181BMini/multi-split18,000 Btu20.29.111,500 Btu/h1
EZCENO18KDucted1.5-ton18.89.111,200 Btu/h1
OBMH301BMini/multi-split30,000 Btu22.3920,000 Btu/h1
OBMH090BMini/multi-split9,000 Btu21.597,000 Btu/h1
OBMH241BMini/multi-split24,000 Btu18.5917,000 Btu/h1
EZCENO36KDucted3-ton16.18.727,000 Btu/h1
EZCENO48KDucted4-ton168.538,000 Btu/h1
EZCENO60KDucted4.5-ton15.28.438,000 Btu/h1

NG Trade R-32 outdoor units

Outdoor unitTypeSizeSEER2HSPF2Heat at 5°FCertified pairings
MOSA32301Mini/multi-split30,000 Btu20–239.5–1023,000–24,600 Btu/h2
MOSA32361Mini/multi-split36,000 Btu20–231025,200–25,600 Btu/h2
MOSA32181Mini/multi-split18,000 Btu19.5–229.5–1014,000–14,500 Btu/h2

NG Trade R-410A outdoor units

Outdoor unitTypeSizeSEER2HSPF2Heat at 5°FCertified pairings
OMEGA091EMini/multi-split9,000 Btu26.411.611,000 Btu/h1
OMEGA181EMini/multi-split18,000 Btu2410.512,800 Btu/h1
OMEGA121EMini/multi-split12,000 Btu23.110.511,000 Btu/h1
OMEGA120EMini/multi-split12,000 Btu22.710.46,700 Btu/h1
MOBMH180CMini/multi-split18,000 Btu19–219.8–10.212,600–13,300 Btu/h3
MOBMH270CMini/multi-split30,000 Btu21–23.59.218,700–19,000 Btu/h3
OBMH090AMini/multi-split9,000 Btu21.59.17,000 Btu/h1
OMEGA241EMini/multi-split24,000 Btu218.516,700 Btu/h1
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Next step

Some links are affiliate links; we may earn a commission at no cost to you. Disclosure.