Refrigerant Finder

Cold-climate heat pumps by refrigerant

148,258 of the 284,747 certified systems carry ENERGY STAR's cold-climate designation.

To earn it, ENERGY STAR's key product criteria require a COP of at least 1.75 at 5°F, heating capacity at 5°F of at least 70% of the capacity at 47°F, and a controls verification test. The designation applies to a specific outdoor and indoor pairing, so the same outdoor unit can be cold-climate with one coil and not another.

The NEEP cold-climate list (ashp.neep.org) is a separate list that many rebate programs use. If a rebate requires NEEP, check that list too.

Top R-454B and R-32 units by heat at 5°F

Outdoor unitBrandRefrigerantTypeSizeHeat at 5°FCOP at 5°FHSPF2Cold-climate pairings
37MPRAQ06AA3Bryant, Carrier +3 moreR-454BMini/multi-split6,000 Btu13,500 Btu/h215.67
A-KZP06SA-1KERR, Kerr KapstoneR-454BMini/multi-split6,000 Btu13,500 Btu/h215.62
A-ZHP06SA-1Comfort Aire, Comfort-AireR-454BMini/multi-split6,000 Btu13,500 Btu/h215.62
A-ZKP06SA-1KERRR-454BMini/multi-split6,000 Btu13,500 Btu/h215.61
AO35-06N2-M1HAI Air ConditioningR-454BMini/multi-split6,000 Btu13,500 Btu/h215.61
BMS635SHYCBlueridgeR-454BMini/multi-split6,000 Btu13,500 Btu/h215.61
BXS6A06UC0BlueridgeR-454BMini/multi-split6,000 Btu13,500 Btu/h215.61
D5CPRAH06AAKAirquest, Arcoaire +9 moreR-454BMini/multi-split6,000 Btu13,500 Btu/h215.611
KEENHYMHP06AAKEEN HomeR-454BMini/multi-split6,000 Btu13,500 Btu/h215.61
LEA06HH-SK-ONovairR-454BMini/multi-split6,000 Btu13,500 Btu/h215.61
ML06HP230CALH-OMainlineR-454BMini/multi-split6,000 Btu13,500 Btu/h215.62
MO1SS-H06B-2AMideaR-454BMini/multi-split6,000 Btu13,500 Btu/h215.61
MOX430-06HFN10-M1HMDVR-454BMini/multi-split6,000 Btu13,500 Btu/h215.63
MUZ-FX06NLHZ***Mitsubishi ElectricR-454BMini/multi-split6,000 Btu12,600 Btu/h2.4131
MUZ-FX06NLHZ2***Mitsubishi ElectricR-454BMini/multi-split6,000 Btu12,600 Btu/h2.4131
AOUH09KTAP1FujitsuR-32Mini/multi-split9,000 Btu17,000 Btu/h2.5144
MXZ-SM36NLHZ-**Mitsubishi ElectricR-454BMini/multi-split24,000 Btu22,000–42,000 Btu/h1.8–28.8–1211
AOUH09KZAH1FujitsuR-32Mini/multi-split9,000 Btu15,400 Btu/h2.313.32
AOUH09KUAH1FujitsuR-32Mini/multi-split9,000 Btu14,700–15,100 Btu/h2–2.211.3–11.82
MUZ-FX09NLHZ***Mitsubishi ElectricR-454BMini/multi-split9,000 Btu14,700 Btu/h2.213.31
MUZ-FX09NLHZ2***Mitsubishi ElectricR-454BMini/multi-split9,000 Btu14,700 Btu/h2.213.31
AOUH12KUAH1FujitsuR-32Mini/multi-split12,000 Btu17,200–18,500 Btu/h1.9–2.110.3–11.56
37MPRAQ09AA3Bryant, Carrier +3 moreR-454BMini/multi-split9,000 Btu13,500 Btu/h214.67
4C35SCH09H21CanAirR-454BMini/multi-split9,000 Btu13,500 Btu/h214.61
A-KZP09SA-1Kerr KapstoneR-454BMini/multi-split9,000 Btu13,500 Btu/h214.61
A-KZPO9SA-1KERRR-454BMini/multi-split9,000 Btu13,500 Btu/h214.61
A-ZHP09SA-1Century, Comfort AireR-454BMini/multi-split9,000 Btu13,500 Btu/h214.62
A-ZHPO9SA-1Comfort Aire, Comfort-AireR-454BMini/multi-split9,000 Btu13,500 Btu/h214.62
A-ZKP09SA-1KERRR-454BMini/multi-split9,000 Btu13,500 Btu/h214.61
AO35-09N2-M1HAI Air ConditioningR-454BMini/multi-split9,000 Btu13,500 Btu/h214.61
BMS933SHYCBlueridgeR-454BMini/multi-split9,000 Btu13,500 Btu/h214.61
BXS6A09UC0BlueridgeR-454BMini/multi-split9,000 Btu13,500 Btu/h214.61
D5CPRAH09AAKAirquest, Arcoaire +9 moreR-454BMini/multi-split9,000 Btu13,500 Btu/h214.611
KEENHYMHP09AAKEEN HomeR-454BMini/multi-split9,000 Btu13,500 Btu/h214.61
LEA09HH-SK-ONovairR-454BMini/multi-split9,000 Btu13,500 Btu/h214.61
ML09HP230CALH-OMainlineR-454BMini/multi-split9,000 Btu13,500 Btu/h214.62
MO1SS-H09B-2AMideaR-454BMini/multi-split9,000 Btu13,500 Btu/h214.61
MOX430-09HFN10-M1HMDVR-454BMini/multi-split9,000 Btu13,500 Btu/h214.63
QO1-M2Z18-NC-NAQuiltR-32Mini/multi-split12,000 Btu12,000–18,000 Btu/h1.9–210–122
SENE-09EL-OHSenvilleR-454BMini/multi-split9,000 Btu13,500 Btu/h214.61

Sorted by the highest certified heat output at 5°F relative to the unit's rated cooling capacity.

Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Next step

Some links are affiliate links; we may earn a commission at no cost to you. Disclosure.