Refrigerant Finder
Guide · checked November 23, 2026

R-454B vs R-410A: what changed and what it means for your heat pump

R-454B replaced R-410A in most new ducted heat pumps in 2025. Here's how they differ, with numbers from ENERGY STAR's certified list.

Short answer: R-454B is the lower-GWP replacement for R-410A in most new ducted heat pumps. It works at similar pressures, but it is an A2L (mildly flammable) refrigerant, so it needs equipment designed for it. You can't put R-454B into an R-410A system, and you can't mix them.

The key differences

R-454BR-410A
Global warming potential (ENERGY STAR data)4702,088
Safety class (ASHRAE)A2L, mildly flammableA1, non-flammable
What it isBlend of R-32 (68.9%) and R-1234yf (31.1%)Blend of R-32 and R-125
New split systemsThe main replacement since January 1, 2025No new manufacture or import since January 1, 2025
Certified systems on ENERGY STAR's list229,21749,743

Efficiency: what the certified data shows

Refrigerant alone doesn't make a system efficient; the compressor, coils and controls do. Still, here is how the certified systems compare today:

RefrigerantTypeSystemsMedian SEER2Median HSPF2Median COP at 5°FCold-climate shareVariable-speed share
R-454BDucted split system220,75316.58.52.0255.2%58.0%
R-410ADucted split system42,33016.08.12.0818.8%28.1%
R-454BMini-split or multi-split8,24521.110.42.095.8%100.0%
R-410AMini-split or multi-split7,23621.010.01.971.0%100.0%

Medians across certified pairings (ENERGY STAR data, November 12, 2026). They describe the products each refrigerant ended up in, not the refrigerant itself.

R-454B ducted systems have a higher median SEER2 and HSPF2 and a much higher cold-climate share, mostly because they are newer product lines with more variable-speed compressors.

What it means for a replacement

  • If your R-410A system is failing, a new R-454B outdoor unit needs a matching R-454B indoor coil or air handler. See why the coil matters.
  • Ask for the AHRI reference number of the full combination and check it in our lookup.
  • A2L systems often need a refrigerant detection sensor, depending on the charge and the space. The manufacturer's instructions decide.
  • Only EPA Section 608 certified technicians can buy and handle these refrigerants.

Sources

Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Next step

Some links are affiliate links; we may earn a commission at no cost to you. Disclosure.