Outdoor unit · ENERGY STAR data November 12, 2026
PH8TAN524**AB*: R-454B heat pump
Sold as Weathermaker. R-454B Ducted split system, 2-ton class, in 197 ENERGY STAR certified pairings with 23 indoor unit models.
- Refrigerant
- R-454B (GWP 470)
- Rated cooling
- 23,000 Btu/h
- SEER2 range
- 15.2–18.5
- HSPF2 range
- 7.8–8.5
- Heat at 5°F
- 10,700–11,400 Btu/h
- Cold-climate pairings
- 0 of 197
- Compressor
- Two-stage
- First certified
- 2026-09-22
This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.
Series: 2-STAGE 18 SEER HP. ENERGY STAR partner: Carrier Corporation.
Certified indoor matches
Top 30 of 197 pairings by SEER2. The AHRI number links to the ENERGY STAR record.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat at 5°F | Cold climate | AHRI ref # |
|---|---|---|---|---|---|---|---|
CVAMA3217XMA* | PG80VTLB36070A** | 18.5 | 14 | 7.8 | 10,900 Btu/h | No | 218754807 |
CVAMA3217XMA* | PG80MSUA36040B** | 18.5 | 14 | 7.8 | 10,800 Btu/h | No | 218754804 |
CAA**3721AM* | PG97VTAA60080C** | 18 | 13 | 8.5 | 11,200 Btu/h | No | 218755691 |
CAA**3721AM* | PG96VTAB60080C** | 18 | 13 | 8.5 | 11,200 Btu/h | No | 218755473 |
CAA**3721AM* | PG95MSUA60100C** | 18 | 13 | 8.5 | 11,200 Btu/h | No | 218755469 |
CAA**3721AM* | PG80VTLB66110C** | 18 | 13 | 8.5 | 11,200 Btu/h | No | 218755465 |
CAA**3721AM* | PG80MSUA60080C** | 18 | 13.5 | 8.5 | 11,100 Btu/h | No | 218755460 |
CAA**3721AM* | PG80MSUA48060B** | 18 | 13.5 | 8.5 | 11,200 Btu/h | No | 218755459 |
CAA**3721AM* | PG80MSUA36040B** | 18 | 13 | 8.5 | 11,100 Btu/h | No | 218755458 |
PF5TNXC36L* | — | 18 | 13 | 8.1 | 10,700 Btu/h | No | 218755544 |
CAA**3721AM* | PG96VTAB60100C** | 18 | 13 | 8.1 | 11,100 Btu/h | No | 218755474 |
CAA**3721AM* | PG96VTAB48060B** | 18 | 13 | 8.1 | 11,200 Btu/h | No | 218755471 |
CAA**3721AM* | PG80VTLB48090B** | 18 | 13 | 8.1 | 11,100 Btu/h | No | 218755463 |
CAA**3721AM* | PG80VTLB48070B** | 18 | 13 | 8.1 | 11,100 Btu/h | No | 218755462 |
CAA**2517AM* | PG80VTLB36070A** | 18 | 13 | 8.1 | 11,000 Btu/h | No | 218755405 |
CAA**2517AM* | PG80MSUA36040B** | 18 | 13 | 8.1 | 11,100 Btu/h | No | 218755402 |
CVAVA3817XMA* | PG80VTLB48090B** | 18 | 14 | 8 | 11,100 Btu/h | No | 218754908 |
CVAVA3817XMA* | PG80VTLB48070B** | 18 | 13.5 | 8 | 11,100 Btu/h | No | 218754907 |
CVAVA3817XMA* | PG96VTAB48060B** | 18 | 13.5 | 7.8 | 11,100 Btu/h | No | 218754913 |
CVAVA3721XMA* | PG96VTAB60080C** | 18 | 13.5 | 7.8 | 10,900 Btu/h | No | 218754902 |
CVAVA3721XMA* | PG80MSUA60100C** | 18 | 13.5 | 7.8 | 10,900 Btu/h | No | 218754890 |
CVAVA3621XMA* | PG96VTAB60080C** | 18 | 13.5 | 7.8 | 10,800 Btu/h | No | 218754885 |
CVAVA3621XMA* | PG80VTLB66110C** | 18 | 13.5 | 7.8 | 10,800 Btu/h | No | 218754878 |
CVAVA3117XMA* | PG80VTLB36045A** | 18 | 13.5 | 7.8 | 11,000 Btu/h | No | 218754851 |
CVAMA3117XMA* | PG96VTAB48060B** | 18 | 13.5 | 7.8 | 11,100 Btu/h | No | 218754802 |
QFVA5D3617X* | — | 18 | 14 | 7.8 | 11,300 Btu/h | No | 218755720 |
CVAVA3817XMA* | PG97VTAA48060B** | 18 | 13.5 | 7.8 | 11,100 Btu/h | No | 218755579 |
CVAVA3721XMA* | PG97VTAA60080C** | 18 | 13.5 | 7.8 | 10,900 Btu/h | No | 218755577 |
CVAMA3117XMA* | PG97VTAA48060B** | 18 | 13.5 | 7.8 | 11,100 Btu/h | No | 218755558 |
PF5TNXB24L* | — | 17.5 | 13 | 8.1 | 11,100 Btu/h | No | 218754765 |
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.
Other R-454B 2-ton units
| Outdoor unit | Brand | SEER2 | HSPF2 | Heat at 5°F | Certified pairings |
|---|---|---|---|---|---|
5A6H7024A1 | American Standard | 15.2–17.1 | 8.1–11 | 16,700–17,700 Btu/h | 245 |
5TWR7024A1 | Trane | 15.2–17.1 | 8.1–11 | 16,700–17,700 Btu/h | 245 |
5TWX7024A1 | Trane | 15.2–18 | 8–11 | 16,700–17,600 Btu/h | 241 |
27VNA324A*030* | Carrier | 18–23 | 8.5–10.5 | 19,100–23,000 Btu/h | 430 |
293VAN024**AA* | Bryant | 18–23 | 8.5–10.5 | 19,100–23,000 Btu/h | 430 |
37MUHAQ24AA3 | Bryant, Carrier +3 more | 16–18.7 | 9–10.5 | 19,100–21,600 Btu/h | 41 |
A-VXP24SA-1 | Century, Comfort Aire +1 more | 16–18.3 | 9.5–10.5 | 19,600–21,600 Btu/h | 12 |
ACIQ-24-HPD | ACiQ, 1HVAC | 16–18.6 | 8.9–10.5 | 19,600–21,600 Btu/h | 19 |