Direct Air · ENERGY STAR data November 12, 2026
Direct Air heat pump refrigerants: R-454B / R-32 / R-410A
Direct Air has 90 ENERGY STAR certified outdoor unit models (48 R-454B, 2 R-32, 40 R-410A) in 320 certified systems.
R-454B 48 (53%)R-32 2 (2%)R-410A 40 (44%)
- Main refrigerant
- R-454B
- Outdoor models
- 90
- Ducted / mini / packaged
- 20 / 70 / 0
- Certified systems
- 320
Some of these outdoor units are also listed under MDV, Alsetria, Eco-air.
Which refrigerant a Direct Air system uses depends on the exact outdoor model, not the brand. Check the model below or in the lookup, and make sure the indoor coil or air handler on your quote is certified with it.
Direct Air R-454B outdoor units
| Outdoor unit | Type | Size | SEER2 | HSPF2 | Heat at 5°F | Certified pairings |
|---|---|---|---|---|---|---|
DIRM4-06HXPRO28-1Z | Mini/multi-split | 6,000 Btu | 25.5 | 14.8 | 7,700 Btu/h | 1 |
DIRM4-09DA25-1Z | Mini/multi-split | 9,000 Btu | 19.7–26 | 11.3–13.9 | 8,000–8,600 Btu/h | 4 |
DIRM4-09HXPRO28-1Z | Mini/multi-split | 9,000 Btu | 20.5–27.4 | 10.9–13.8 | 11,000–11,900 Btu/h | 4 |
DIRM4-24HXPRO28-1Z | Mini/multi-split | 24,000 Btu | 19–21 | 11.6–13.5 | 23,800–24,200 Btu/h | 4 |
DIRM4-18HXPRO28-1Z | Mini/multi-split | 18,000 Btu | 18.4–21.4 | 10.3–12.3 | 17,000–18,000 Btu/h | 4 |
DIRM4-24DA25-1Z | Mini/multi-split | 24,000 Btu | 19–23 | 10.5–11.7 | 18,500–19,600 Btu/h | 4 |
DIRM4-12HXPRO28-1Z | Mini/multi-split | 12,000 Btu | 20–25.4 | 10.5–11.6 | 11,300–12,000 Btu/h | 4 |
DIRM4-18DA25-1Z | Mini/multi-split | 18,000 Btu | 20–23.5 | 10.4–11.4 | 12,800–14,200 Btu/h | 4 |
DIRM4-36LCHX-1Z | Mini/multi-split | 36,000 Btu | 17.7–21.2 | 10.6–11.1 | 37,000–39,500 Btu/h | 3 |
DIRM4-12DA25-1Z | Mini/multi-split | 12,000 Btu | 19.5–25.5 | 10.4–11 | 8,400–8,900 Btu/h | 4 |
DIRH4-09HP25-DKO | Mini/multi-split | 9,000 Btu | 25 | 11 | 9,000 Btu/h | 1 |
DIRM4-48HXPRO28-5Z | Mini/multi-split | 48,000 Btu | 20.4–23 | 11 | 47,000–48,000 Btu/h | 3 |
DIRM4-48HXPRO28-6Z | Mini/multi-split | 48,000 Btu | 20.4–23 | 11 | 47,000–48,000 Btu/h | 3 |
DIRM4-48LCHX-1Z | Mini/multi-split | 48,000 Btu | 16.7–18.5 | 10.1–11 | 47,000–47,500 Btu/h | 3 |
DIRM4-36HXPRO28-4Z | Mini/multi-split | 36,000 Btu | 19.4–23 | 10.4–10.7 | 36,000–38,000 Btu/h | 3 |
DIRM4-36HXPRO28-5Z | Mini/multi-split | 36,000 Btu | 19.4–23 | 10.4–10.7 | 36,000–38,000 Btu/h | 3 |
DIRM4-60HXPRO28-6Z | Mini/multi-split | 48,000 Btu | 20–22.2 | 10.5–10.7 | 47,000–48,000 Btu/h | 3 |
DIRM4-48DA25-5Z | Mini/multi-split | 48,000 Btu | 20.4–24 | 10.3–10.6 | 36,000–38,000 Btu/h | 3 |
DIRM4-48DA25-6Z | Mini/multi-split | 48,000 Btu | 20.4–24 | 10.3–10.6 | 36,000–38,000 Btu/h | 3 |
DIRM4-27DA25-3Z | Mini/multi-split | 30,000 Btu | 19–23 | 9.5–10.5 | 27,000 Btu/h | 3 |
DIRM4-28HXPRO28-3Z | Mini/multi-split | 30,000 Btu | 19–23 | 9.5–10.5 | 27,000 Btu/h | 3 |
DIRM4-28HXPRO28-4Z | Mini/multi-split | 30,000 Btu | 19–23 | 9.5–10.5 | 27,000 Btu/h | 3 |
DIRM4-18HXPRO28-2Z | Mini/multi-split | 18,000 Btu | 20–25 | 10–10.4 | 18,000–19,000 Btu/h | 3 |
DIRM4-18HXPRO28-3Z | Mini/multi-split | 18,000 Btu | 20–25 | 10–10.4 | 18,000–19,000 Btu/h | 3 |
DIRM4-36LCDA25-1Z | Mini/multi-split | 36,000 Btu | 20 | 10.3 | 26,600 Btu/h | 1 |
All 48 Direct Air R-454B outdoor units
Direct Air R-32 outdoor units
| Outdoor unit | Type | Size | SEER2 | HSPF2 | Heat at 5°F | Certified pairings |
|---|---|---|---|---|---|---|
DIRH3-18HP21-DKO | Mini/multi-split | 18,000 Btu | 20 | 9.8 | 13,400 Btu/h | 1 |
DIRH3-09HP21-DKO | Mini/multi-split | 9,000 Btu | 22.5 | 9 | 5,400 Btu/h | 1 |
Direct Air R-410A outdoor units
| Outdoor unit | Type | Size | SEER2 | HSPF2 | Heat at 5°F | Certified pairings |
|---|---|---|---|---|---|---|
DIRM-06HXPRO28-1Z | Mini/multi-split | 6,000 Btu | 26.5 | 13.6 | 7,500 Btu/h | 1 |
DIRM-09DA25-1Z | Mini/multi-split | 9,000 Btu | 19.2–25.5 | 10–12.3 | 7,400–8,000 Btu/h | 5 |
DIRM-09HXPRO28-1Z | Mini/multi-split | 9,000 Btu | 20.2–28.1 | 10.3–12 | 10,000–10,800 Btu/h | 5 |
MOD30-24HFN1-MU0W | Mini/multi-split | 24,000 Btu | 15.2–22.3 | 8.5–11.5 | 21,200–27,000 Btu/h | 19 |
DIRM-24HXPRO28-1Z | Mini/multi-split | 24,000 Btu | 19.2–21.5 | 10.5–11.5 | 25,000–27,000 Btu/h | 4 |
MOX430-17HFN1-MT0W | Mini/multi-split | 18,000 Btu | 15.2–22 | 8.9–11.3 | 14,600–18,000 Btu/h | 28 |
DIRM-18HXPRO28-1Z | Mini/multi-split | 18,000 Btu | 18–21.5 | 9.5–11.3 | 16,000–18,000 Btu/h | 7 |
DIRM-24DA25-1Z | Mini/multi-split | 24,000 Btu | 19–22 | 9.7–11.2 | 15,500–20,000 Btu/h | 7 |
DIRM-18DA25-1Z | Mini/multi-split | 18,000 Btu | 20–23.5 | 10–10.8 | 11,300–13,000 Btu/h | 7 |
DIRM-12DA25-1Z | Mini/multi-split | 12,000 Btu | 19–24.6 | 10–10.7 | 8,000–8,400 Btu/h | 6 |
DIRM-28HXPRO28-3Z | Mini/multi-split | 30,000 Btu | 20–23 | 9.5–10.6 | 25,000 Btu/h | 5 |
DIR-09HP28-TQO | Mini/multi-split | 9,000 Btu | 27.5 | 10.5 | 7,000 Btu/h | 1 |
DIRM-18DA25-2Z | Mini/multi-split | 18,000 Btu | 19–22.9 | 9.8–10.5 | 12,600–13,300 Btu/h | 5 |
DIRM-12HXPRO28-1Z | Mini/multi-split | 12,000 Btu | 19.5–25.5 | 10–10.4 | 11,300–12,100 Btu/h | 10 |
DIRM-36HXPRO28-4Z | Mini/multi-split | 36,000 Btu | 19–22.2 | 10–10.3 | 33,000–36,000 Btu/h | 4 |
DIRM-24MAGICPRO20-OU | Ducted | 2-ton | 16.1–17.4 | 9.5–10.2 | 20,000–22,600 Btu/h | 4 |
DIRM-48LCDA25-1Z | Mini/multi-split | 48,000 Btu | 18.9 | 10 | 35,000 Btu/h | 2 |
DIRM-36MAGICPRO20-OU | Ducted | 3-ton | 15.2–16 | 8.6–10 | 31,600–34,400 Btu/h | 3 |
DIR-12HP28-TQO | Mini/multi-split | 12,000 Btu | 23.5 | 9.8 | 8,400 Btu/h | 1 |
DIRM-18HXPRO28-2Z | Mini/multi-split | 18,000 Btu | 19–22 | 9.3–9.8 | 19,000–19,700 Btu/h | 3 |
DIRM-48HXPRO28-5Z | Mini/multi-split | 48,000 Btu | 20.9–21.8 | 9–9.8 | 42,500–45,000 Btu/h | 3 |
DIRM-30MAGICPRO20-OU | Ducted | 2.5-ton | 15.5–16.2 | 8.9–9.7 | 24,000–27,000 Btu/h | 2 |
DIRM-27DA25-3Z | Mini/multi-split | 30,000 Btu | 21–24.6 | 9.2–9.5 | 18,700–19,000 Btu/h | 5 |
DIRM-36DA25-4Z | Mini/multi-split | 36,000 Btu | 20–23.9 | 9.2–9.5 | 24,000–25,200 Btu/h | 3 |
DIRH-12HP23-DKO | Mini/multi-split | 12,000 Btu | 21 | 9.5 | 8,400 Btu/h | 1 |
All 40 Direct Air R-410A outdoor units
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.