Outdoor unit · ENERGY STAR data November 12, 2026
EL21KLV-024-230A**: R-454B heat pump
Sold as Lennox. R-454B Ducted split system, 2-ton class, in 178 ENERGY STAR certified pairings with 20 indoor unit models.
- Refrigerant
- R-454B (GWP 470)
- Rated cooling
- 23,400 Btu/h
- SEER2 range
- 15.2–21
- HSPF2 range
- 8.1–10.2
- Heat at 5°F
- 13,900–18,600 Btu/h
- Cold-climate pairings
- 94 of 178
- Compressor
- Continuously variable
- First certified
- 2025-05-15
This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.
Series: Elite EL21KLV SERIES, Elite EL21KLV Series. ENERGY STAR partner: Lennox Industries.
Certified indoor matches
Top 30 of 178 pairings by SEER2. The AHRI number links to the ENERGY STAR record.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat at 5°F | Cold climate | AHRI ref # |
|---|---|---|---|---|---|---|---|
CK40HT-24B-**+TDR | ML197UH030XE36B* | 21 | 13.5 | 8.2 | 18,100 Btu/h | Yes | 218745112 |
CBK48MVT-030-230-** | — | 20.5 | 12 | 10 | 17,900 Btu/h | Yes | 217115278 |
CBK48MVT-018/024-230-** | — | 20.5 | 13 | 10 | 18,600 Btu/h | Yes | 217115280 |
CBK47UHET-024-230-** | — | 20.5 | 13 | 9.8 | 18,600 Btu/h | Yes | 217121964 |
CBK47UHET-030-230-** | — | 20.5 | 13 | 9.8 | 17,900 Btu/h | Yes | 217121963 |
CK40HT-30A-**+TDR | EL280UH045E36A* | 20.5 | 12.5 | 9 | 16,700 Btu/h | No | 217443193 |
CBK45UHVT-030-230-** | — | 20.5 | 13 | 8.5 | 17,800 Btu/h | Yes | 217121962 |
CK40DT-30/36C-**+TDR | SLP99DF090XV36C* | 20.5 | 13 | 8.5 | 16,200 Btu/h | No | 217443154 |
CK40[C,U]T-30B-**+TDR | SL297UH040NV36B* | 20 | 12.8 | 10 | 17,700 Btu/h | Yes | 217115288 |
CK40[C,U]T-30A-**+TDR | EL180UH040NE36A* | 20 | 12.6 | 9.8 | 17,600 Btu/h | Yes | 217121529 |
CK40[C,U]T-30A-**+TDR | EL180UH060NE36A* | 20 | 12.6 | 9.8 | 17,600 Btu/h | Yes | 217121530 |
CBK45UHVT-024-230-** | — | 20 | 13 | 9.8 | 17,300 Btu/h | No | 217443134 |
CK40[C,U]T-30A-**+TDR | ML180UH070V36A* | 20 | 13 | 9.6 | 17,400 Btu/h | Yes | 217121548 |
CK40[C,U]T-30B-**+TDR | ML180UH070V36B* | 20 | 13 | 9.6 | 17,400 Btu/h | Yes | 217121549 |
CK40[C,U]T-30B-**+TDR | ML180UH090V48B* | 20 | 12.6 | 9.6 | 17,700 Btu/h | Yes | 217121553 |
CK40HT-30B-**+TDR | SL280UH090V36B* | 20 | 13 | 9.4 | 17,000 Btu/h | Yes | 217443174 |
CK40HT-30B-**+TDR | SL297UH040NV36B* | 20 | 13 | 9.4 | 17,100 Btu/h | Yes | 217443176 |
CK40HT-30B-**+TDR | SL297UH060NV36B* | 20 | 13 | 9.4 | 17,100 Btu/h | Yes | 217443177 |
CK40HT-30B-**+TDR | SLP99UH070XV36B* | 20 | 13 | 9.4 | 17,000 Btu/h | Yes | 217443178 |
CK40HT-30B-**+TDR | EL297UH070XV36B* | 20 | 13 | 9.4 | 17,000 Btu/h | No | 217443185 |
CK40HT-30B-**+TDR | ML180UH070V36B* | 20 | 13 | 9 | 16,900 Btu/h | Yes | 217443162 |
CK40HT-30B-**+TDR | ML180UH090V48B* | 20 | 13 | 9 | 17,100 Btu/h | Yes | 217443166 |
CK40HT-30A-**+TDR | SL280UH060NV36A* | 20 | 12.5 | 9 | 17,100 Btu/h | No | 217443201 |
CK40DT-30/36B-**+TDR | SL280DF090V48B* | 20 | 12.5 | 8.5 | 16,300 Btu/h | No | 217443143 |
CK40DT-30/36B-**+TDR | EL297DF045XV36B* | 20 | 12.5 | 8.5 | 16,200 Btu/h | No | 217443144 |
CK40DT-30/36B-**+TDR | SLP99DF070XV36B* | 20 | 12.5 | 8.5 | 16,300 Btu/h | No | 217443145 |
CK40HT-30B-**+TDR | ML180UH070V48B* | 20 | 13 | 8.5 | 16,900 Btu/h | Yes | 217443164 |
CK40HT-24A-**+TDR | EL180UH040NE36A* | 20 | 13 | 8.5 | 17,500 Btu/h | Yes | 217443186 |
CK40HT-24A-**+TDR | EL280UH070XE36A* | 20 | 13 | 8.5 | 17,600 Btu/h | Yes | 217443187 |
CK40HT-24A-**+TDR | EL180UH060NE36A* | 20 | 13 | 8.5 | 17,500 Btu/h | Yes | 217443188 |
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.
Other R-454B 2-ton units
| Outdoor unit | Brand | SEER2 | HSPF2 | Heat at 5°F | Certified pairings |
|---|---|---|---|---|---|
5A6H7024A1 | American Standard | 15.2–17.1 | 8.1–11 | 16,700–17,700 Btu/h | 245 |
5TWR7024A1 | Trane | 15.2–17.1 | 8.1–11 | 16,700–17,700 Btu/h | 245 |
5TWX7024A1 | Trane | 15.2–18 | 8–11 | 16,700–17,600 Btu/h | 241 |
27VNA324A*030* | Carrier | 18–23 | 8.5–10.5 | 19,100–23,000 Btu/h | 430 |
293VAN024**AA* | Bryant | 18–23 | 8.5–10.5 | 19,100–23,000 Btu/h | 430 |
37MUHAQ24AA3 | Bryant, Carrier +3 more | 16–18.7 | 9–10.5 | 19,100–21,600 Btu/h | 41 |
A-VXP24SA-1 | Century, Comfort Aire +1 more | 16–18.3 | 9.5–10.5 | 19,600–21,600 Btu/h | 12 |
ACIQ-24-HPD | ACiQ, 1HVAC | 16–18.6 | 8.9–10.5 | 19,600–21,600 Btu/h | 19 |