Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

EL18KSLV-036-230A**: R-454B heat pump

Sold as Lennox. R-454B Ducted split system, 3-ton class, in 355 ENERGY STAR certified pairings with 27 indoor unit models.

Refrigerant
R-454B (GWP 470)
Rated cooling
34,400 Btu/h
SEER2 range
15.2–19.3
HSPF2 range
8.1–9.6
Heat at 5°F
27,600–30,800 Btu/h
Cold-climate pairings
355 of 355
Compressor
Continuously variable
First certified
2025-03-20

This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: Elite EL18KSLV Series, EL18KSLV Series, EL18KSLV SERIES. ENERGY STAR partner: Lennox Industries.

Certified indoor matches

Top 30 of 355 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
CK40HT-42B-**+TDR
EL297UH070XV36B*19.311.79.127,600 Btu/hYes218672219
CBK48MVT-042-230-**
—1911.79.429,400 Btu/hYes216618914
CK40HT-36C-**+TDR
ML196UH090XE36C*18.911928,400 Btu/hYes217449921
CK40[C,U]T-36C-**+TDR
ML180UH110V60C*18.8118.528,200 Btu/hYes218082917
CK40HT-36C-**+TDR
ML193UH090XE36C*18.711928,200 Btu/hYes217449922
CK40[C,U]T-36B-**+TDR
EL280UH090E36B*18.6118.528,200 Btu/hYes217449852
CK40HT-30A-**+TDR
EL280UH045E36A*18.611928,400 Btu/hYes217189835
CK40HT-36B-**+TDR
EL280UH090E36B*18.6118.528,400 Btu/hYes217449902
CK40HT-36C-**+TDR
ML296UH090XV48C*18.611928,200 Btu/hYes217449930
CK40HT-30B-**+TDR
EL280UH090E36B*18.6118.528,400 Btu/hYes217449877
CK40[C,U]T-36C-**+TDR
ML296UH110XV60C*18.6118.528,400 Btu/hYes218082924
CK40[C,U]T-36C-**+TDR
ML196UH090XE36C*18.6118.528,200 Btu/hYes218082922
CBK48MVT-036-230-**
—18.5119.429,400 Btu/hYes216618913
CBK47UHET-036-230-**
—18.5119.429,400 Btu/hYes216705371
CBK45UHET-036-230-**
—18.511.7930,000 Btu/hYes216618909
CK40[C,U]T-36A-**+TDR
EL280UH045E36A*18.5118.528,600 Btu/hYes217189812
CK40[C,U]T-30/36C**+TDR
ML196UH090XE36C*18.4108.528,600 Btu/hYes217677937
CK40HT-36C-**+TDR
EL297UH090XV48C*18.411.7928,200 Btu/hYes217449926
CK40[C,U]T-36C-**+TDR
SL280UH090XV60C*18.4118.528,200 Btu/hYes218082927
CK40[C,U]T-36C-**+TDR
SL280UH090V60C*18.4118.528,200 Btu/hYes218082926
CK40HT-36C-**+TDR
EL297UH110XV48C*18.411928,200 Btu/hYes217449927
CK40[C,U]T-30/36C**+TDR
ML193UH090XE36C*18.4108.528,400 Btu/hYes217677938
CK40DT-42B-**+TDR
ML193DF045XE36B*18.311928,200 Btu/hYes217449943
CK40[C,U]T-30B-**+TDR
EL280UH090E36B*18.3118.528,400 Btu/hYes217449827
CK40[C,U]T-36B-**+TDR
ML180UH070V48B*18.311.78.528,200 Btu/hYes217449868
CK40[C,U]T-36C-**+TDR
SL280UH110XV60C*18.3118.528,400 Btu/hYes218082930
CK40[C,U]T-36C-**+TDR
SL280UH110V60C*18.3118.528,400 Btu/hYes218082929
CK40[C,U]T-36C-**+TDR
ML193UH090XE36C*18.3118.528,000 Btu/hYes218082919
CK40HT-30B-**+TDR
ML180UH070V48B*18.2118.528,400 Btu/hYes217449893
CBK45UHVT-042-230-**
—18.211.7930,000 Btu/hYes216618912
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-454B 3-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
MCY-MUB0368HS2P-ULToshiba Carrier16.6–29.78.2–12.221,000–28,200 Btu/h7
5A6V0X36A1American Standard19.2–219.4–10.523,800–25,400 Btu/h112
5TWV0X36A1Trane19.2–219.4–10.523,800–25,400 Btu/h112
D5CSHAH33AAKAirquest, Arcoaire +11 more16.7–19.610–10.534,000–35,000 Btu/h25
SL22KLV-036-230A**Lennox16.5–20.58–10.524,400–34,000 Btu/h80
A7CP21V36P-**AAirease, Armstrong Air +1 more15.2–208.5–10.418,400–25,400 Btu/h529
EL21KLV-036-230A**Lennox15.2–208.5–10.418,400–25,400 Btu/h299
NS21H36MA5-**AGE15.2–208.5–10.418,400–24,400 Btu/h133

All 264 R-454B 3-ton units

More Lennox R-454B units

Next step

Some links are affiliate links; we may earn a commission at no cost to you. Disclosure.