Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

A7CP21V36P-**A: R-454B heat pump

Sold as Airease, Armstrong Air, AC Pro. R-454B Ducted split system, 3-ton class, in 529 ENERGY STAR certified pairings with 16 indoor unit models.

Refrigerant
R-454B (GWP 470)
Rated cooling
33,400 Btu/h
SEER2 range
15.2–20
HSPF2 range
8.5–10.4
Heat at 5°F
18,400–25,400 Btu/h
Cold-climate pairings
327 of 529
Compressor
Continuously variable
First certified
2025-05-15

This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: A7CP21V Series, A7CP21V SERIES. ENERGY STAR partner: Allied Air Enterprises.

Certified indoor matches

Top 30 of 529 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
7AH2AV36PXC**
—2011.71025,400 Btu/hYes217465755
7AH2AV36PXC**
—2011.71025,400 Btu/hYes217117579
7AH2AV36PXC**
—2011.71025,400 Btu/hYes217117575
7AH1AV42PX-**
—2012.2923,800 Btu/hYes217465906
7AH1AV42PX-**
—2012.2923,800 Btu/hYes217122172
7AH1AV42PX-**
—2012.2923,800 Btu/hYes217122071
7E[C,U]30BX-**+TDR
A80US2V090B12*19.511.710.422,800 Btu/hNo217466065
7E[C,U]30BX-**+TDR
A80US2V090B12*19.511.710.422,800 Btu/hNo217446491
7E[C,U]30BX-**+TDR
A80US2V090B12*19.511.710.422,800 Btu/hNo217446260
7ED30/36BX-**+TDR
A97DSMV070B12S*19.511.29.219,200 Btu/hNo217466083
7ED30/36BX-**+TDR
A97DSMV070B12S*19.511.29.219,200 Btu/hNo217446509
7ED30/36BX-**+TDR
A97DSMV070B12S*19.511.29.219,200 Btu/hNo217446278
7AH1AE42PX-**
—19.511.78.524,400 Btu/hYes217465956
7AH1AV36PX-**
—19.5128.524,200 Btu/hYes217465958
7AH1AE42PX-**
—19.511.78.524,400 Btu/hYes217122222
7AH1AV36PX-**
—19.5128.524,200 Btu/hYes217122224
7AH1AE42PX-**
—19.511.78.524,400 Btu/hYes217122121
7AH1AV36PX-**
—19.5128.524,200 Btu/hYes217122123
7E[C,U]30AX-**+TDR
A80UH1E040A12X*1911.210.422,600 Btu/hNo217466177
7E[C,U]30AX-**+TDR
A80UH1E060A12X*1911.210.422,600 Btu/hNo217466046
7E[C,U]30AX-**+TDR
A80UH2E070A12*1911.510.422,400 Btu/hNo217466048
7E[C,U]30AX-**+TDR
A80UH1E045A12*1911.510.422,400 Btu/hNo217466049
7E[C,U]30BX-**+TDR
A80UH2E090B12*1911.710.422,400 Btu/hNo217466055
7E[C,U]30BX-**+TDR
A80US2V080B16X*1911.210.423,000 Btu/hNo217466064
7E[C,U]30BX-**+TDR
A80US2V090B16*1911.510.422,800 Btu/hNo217466066
7E[C,U]30BX-**+TDR
A80US2V090B16L*1911.510.422,800 Btu/hNo217466067
7E[C,U]30BX-**+TDR
A97US2V040B12X*1911.210.423,200 Btu/hNo217466068
7E[C,U]30BX-**+TDR
A98USMV070B12S*1911.510.422,800 Btu/hNo217466070
7E[C,U]30BX-**+TDR
A97US2V045B12S*1911.210.423,000 Btu/hNo217466073
7E[C,U]30BX-**+TDR
A97US2V070B12S*1911.510.423,000 Btu/hNo217466074
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-454B 3-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
MCY-MUB0368HS2P-ULToshiba Carrier16.6–29.78.2–12.221,000–28,200 Btu/h7
5A6V0X36A1American Standard19.2–219.4–10.523,800–25,400 Btu/h112
5TWV0X36A1Trane19.2–219.4–10.523,800–25,400 Btu/h112
D5CSHAH33AAKAirquest, Arcoaire +11 more16.7–19.610–10.534,000–35,000 Btu/h25
SL22KLV-036-230A**Lennox16.5–20.58–10.524,400–34,000 Btu/h80
EL21KLV-036-230A**Lennox15.2–208.5–10.418,400–25,400 Btu/h299
NS21H36MA5-**AGE15.2–208.5–10.418,400–24,400 Btu/h133
37MUHAQ36AA3Bryant, Carrier +3 more15.8–189.4–10.334,600–39,000 Btu/h38

All 264 R-454B 3-ton units

More Airease R-454B units

Next step