Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

5TWV0X36A1: R-454B heat pump

Sold as Trane. R-454B Ducted split system, 3-ton class, in 112 ENERGY STAR certified pairings with 16 indoor unit models.

Refrigerant
R-454B (GWP 470)
Rated cooling
35,600 Btu/h
SEER2 range
19.2–21
HSPF2 range
9.4–10.5
Heat at 5°F
23,800–25,400 Btu/h
Cold-climate pairings
111 of 112
Compressor
Continuously variable
First certified
2025-07-03

This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: 20 TruComfort Variable Speed Heat Pump. ENERGY STAR partner: Trane and American Standard Heating and Air Conditioning.

Certified indoor matches

Top 30 of 112 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
5PX*D010AS3
S8V2D120M5PDB21131024,600 Btu/hYes216453109
5PX*D010AS3
S8V2D120M5PCB21131024,600 Btu/hYes216453111
5TAMXD06AV41
—2112.79.724,800 Btu/hYes216440114
5TXCD010AS3
S8V2D120M5PDB20.8131024,600 Btu/hYes216453137
5TXCD010AS3
S8V2D120M5PCB20.8131024,600 Btu/hYes216453139
5PX*C009AS3
*UHMC100CCV4+LRP20.6139.724,400 Btu/hYes216570992
5TXCC009AS3
*UHMC100CCV4+LRP20.6139.724,400 Btu/hYes216571074
5PX*C009AS3
S9V2B060D3VSB+LRP20.612.79.724,600 Btu/hYes217179369
5PX*CD09AS3
S9V2B060D3VSB+VCKIT20.612.59.724,400 Btu/hYes218036347
5TXCC009AS3
S9V2B060D3PSC+LRP20.612.79.524,600 Btu/hYes217179429
5TXCC009AS3
S9V2B060D3VSB+LRP20.612.79.524,600 Btu/hYes217179431
5TXCC009AS3
S9V2C080U5VSB+VCKIT20.612.79.423,800 Btu/hYes218036359
5TXCC009AS3
S9V2C100U4VSB+VCKIT20.612.79.423,800 Btu/hYes218036357
5TXCC009AS3
S9V2C100U5VSB+VCKIT20.612.79.423,800 Btu/hYes218036355
5PX*C009AS3
S9V2C100U5VSB+VCKIT20.612.79.423,800 Btu/hYes218036341
5PX*C009AS3
S9V2C100U4VSB+VCKIT20.612.79.423,800 Btu/hYes218036339
5PX*C009AS3
S9V2C080U5VSB+VCKIT20.612.79.423,800 Btu/hYes218036337
5TAMXD05AV41
—20.412.71024,600 Btu/hYes216440112
5PX*DD10AS3
S8V2D120M5PDB20.412.79.724,600 Btu/hYes216453113
5PX*DD10AS3
S8V2D120M5PCB20.412.79.724,600 Btu/hYes216453115
5PX*C009AS3
S9V2B060D3PSC+LRP20.412.79.724,600 Btu/hYes217179383
5PX*C009AS3
*UHMB080CCV3+LRP20.412.79.724,600 Btu/hYes217179399
5PX*C009AS3
*UHMB060CCV3+LRP20.412.79.724,800 Btu/hYes217179401
5TXCC009AS3
*UHMB060CCV3+LRP20.412.79.724,800 Btu/hYes217179437
5TXCC009AS3
*UHMB080CCV3+LRP20.412.79.724,600 Btu/hYes217179461
5TXCC009AS3
S9V2B040U3VSB+VCKIT20.212.51024,800 Btu/hYes218036365
5PX*C009AS3
S9V2B060U3VSB+LRP20.212.79.724,800 Btu/hYes217179367
5PX*C009AS3
S9V2B060U4VSB+LRP20.212.79.724,800 Btu/hYes217179371
5PX*C009AS3
S9V2B060U4PSC+LRP20.212.79.724,800 Btu/hYes217179381
5PX*C009AS3
S8V2B080M4PCB20.212.79.724,800 Btu/hYes217179393
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-454B 3-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
MCY-MUB0368HS2P-ULToshiba Carrier16.6–29.78.2–12.221,000–28,200 Btu/h7
5A6V0X36A1American Standard19.2–219.4–10.523,800–25,400 Btu/h112
D5CSHAH33AAKAirquest, Arcoaire +11 more16.7–19.610–10.534,000–35,000 Btu/h25
SL22KLV-036-230A**Lennox16.5–20.58–10.524,400–34,000 Btu/h80
A7CP21V36P-**AAirease, Armstrong Air +1 more15.2–208.5–10.418,400–25,400 Btu/h529
EL21KLV-036-230A**Lennox15.2–208.5–10.418,400–25,400 Btu/h299
NS21H36MA5-**AGE15.2–208.5–10.418,400–24,400 Btu/h133
37MUHAQ36AA3Bryant, Carrier +3 more15.8–189.4–10.334,600–39,000 Btu/h38

All 264 R-454B 3-ton units

More Trane R-454B units

Next step