Armstrong Air · ENERGY STAR data November 12, 2026
Armstrong Air heat pump refrigerants: R-454B / R-410A
Armstrong Air has 44 ENERGY STAR certified outdoor unit models (19 R-454B, 25 R-410A) in 8,216 certified systems.
R-454B 19 (43%)R-410A 25 (57%)
- Main refrigerant
- R-410A
- Outdoor models
- 44
- Ducted / mini / packaged
- 27 / 13 / 4
- Certified systems
- 8,216
Sister brands. Armstrong Air lists almost the same outdoor units as Airease. They are usually the same equipment sold under different names, so compare installer, warranty and price rather than the badge.
Some of these outdoor units are also listed under Airease, Allied, Ducane, Concord, AC Pro.
Which refrigerant a Armstrong Air system uses depends on the exact outdoor model, not the brand. Check the model below or in the lookup, and make sure the indoor coil or air handler on your quote is certified with it.
Armstrong Air R-454B outdoor units
| Outdoor unit | Type | Size | SEER2 | HSPF2 | Heat at 5°F | Certified pairings |
|---|---|---|---|---|---|---|
A7CP21V36P-**A | Ducted | 3-ton | 15.2–20 | 8.5–10.4 | 18,400–25,400 Btu/h | 529 |
A7CP21V24P-**A | Ducted | 2-ton | 15.2–21 | 7.8–10.2 | 13,900–18,600 Btu/h | 391 |
A7SCP18V24P-**A | Ducted | 2-ton | 15.2–18.5 | 8.5–10 | 20,000–23,400 Btu/h | 268 |
A7CP21V48P-**A | Ducted | 4-ton | 15.7–20.5 | 7.8–9.6 | 29,000–39,500 Btu/h | 408 |
A7SCP18V36P-**A | Ducted | 3-ton | 15.2–19 | 8.1–9.6 | 28,000–30,800 Btu/h | 432 |
A7SCP18V60P-**A | Ducted | 4-ton | 15.2–18.3 | 8.1–9.6 | 39,000–45,000 Btu/h | 500 |
A7CP21V60P-**A | Ducted | 4.5-ton | 16–20.5 | 8.1–9 | 31,600–38,500 Btu/h | 244 |
A7HP19V60P-**A | Ducted | 4-ton | 16.5–18.5 | 7.8–9 | 21,800–29,600 Btu/h | 128 |
A7HP19V36P-**A | Ducted | 2-ton | 15.2–20 | 7.8–8.5 | 12,100–17,700 Btu/h | 404 |
A7HP14F24P-**A | Ducted | 2-ton | 15.2–16 | 7.8–8.2 | 10,500–11,600 Btu/h | 264 |
A7HP14F30P-**A | Ducted | 2.5-ton | 15.2–16 | 7.8–8.2 | 12,600–14,300 Btu/h | 60 |
A7HP14F42P-**A | Ducted | 3.5-ton | 15.2–15.5 | 7.8–8.2 | 19,000–20,800 Btu/h | 128 |
A7HP14F48P-**A | Ducted | 4-ton | 15.2–15.5 | 7.8–8.2 | 23,400–24,600 Btu/h | 38 |
A7HP14F36P-**A | Ducted | 3-ton | 15.2–16 | 7.8–8 | 15,700–16,900 Btu/h | 80 |
A7HP14F18P-**A | Ducted | 1.5-ton | 15.2–16.5 | 7.8 | 7,900–8,500 Btu/h | 102 |
RPHPV-71524P-* | Packaged | 2-ton | 16 | 7.2 | 8,300 Btu/h | 5 |
RPHPV-71536P-* | Packaged | 3-ton | 15.2 | 7.2 | 15,200 Btu/h | 5 |
RPHPV-71548P-* | Packaged | 4-ton | 15.2 | 7.2 | 20,400 Btu/h | 5 |
RPHPV-71560P-* | Packaged | 5-ton | 15.2 | 7.2 | 24,600 Btu/h | 5 |
Armstrong Air R-410A outdoor units
| Outdoor unit | Type | Size | SEER2 | HSPF2 | Heat at 5°F | Certified pairings |
|---|---|---|---|---|---|---|
4DHPS209S-1P | Mini/multi-split | 9,000 Btu | 19.2–26.5 | 10–13.6 | 7,400–8,000 Btu/h | 52 |
4DHP2S09S-1P | Mini/multi-split | 9,000 Btu | 19.2–25.5 | 10–12.3 | 7,400–8,000 Btu/h | 24 |
4DHP2S24S-1P | Mini/multi-split | 24,000 Btu | 19–22 | 9.6–11 | 15,500–20,000 Btu/h | 38 |
4DHP2S12S-1P | Mini/multi-split | 12,000 Btu | 18.8–24.6 | 9.9–10.7 | 8,000–8,400 Btu/h | 39 |
4DHP2S18S-1P | Mini/multi-split | 18,000 Btu | 20–23.5 | 10.4–10.7 | 11,300–13,000 Btu/h | 43 |
4DHP2S18M-1P | Mini/multi-split | 18,000 Btu | 19–22.9 | 9.8–10.5 | 12,600–13,300 Btu/h | 18 |
4DHP2S24M-1P | Mini/multi-split | 24,000 Btu | 21.3–24.6 | 9.7–10 | 18,000–18,500 Btu/h | 19 |
4DHP2S12S-1L | Mini/multi-split | 12,000 Btu | 22.4–23.5 | 7.8–10 | 5,600–6,800 Btu/h | 10 |
4DHP2S48M-1P | Mini/multi-split | 48,000 Btu | 20.9–21.8 | 9–9.8 | 42,500–45,000 Btu/h | 17 |
4DHP2S36M-1P | Mini/multi-split | 36,000 Btu | 23.9 | 9.5 | 25,200 Btu/h | 7 |
4DHV2S09S-1P | Mini/multi-split | 9,000 Btu | 21.7 | 9.4 | 7,000 Btu/h | 14 |
4DHP2S30M-1P | Mini/multi-split | 30,000 Btu | 20.7–24.6 | 9.2–9.3 | 18,700–19,000 Btu/h | 19 |
4DHV2S09S-1L | Mini/multi-split | 9,000 Btu | 21.5 | 9.1 | 7,000 Btu/h | 13 |
4SHP22LX124P-**A | Ducted | 2-ton | 17.5–21 | 8.8–9 | 14,900–16,100 Btu/h | 6 |
4SHP22LX136P-**A | Ducted | 3-ton | 20 | 9 | 18,300 Btu/h | 2 |
4SHP22LX160P-**A | Ducted | 4.5-ton | 16–19 | 7.8–8.7 | 29,600–31,200 Btu/h | 48 |
4SHP17LE136P-**A | Ducted | 3-ton | 15.2–16.8 | 7.8–8.7 | 16,800–19,300 Btu/h | 908 |
4SHP17LE130P-**A | Ducted | 2.5-ton | 15.2–16.2 | 7.8–8.6 | 13,200–15,400 Btu/h | 667 |
4SHP22LX148P-**A | Ducted | 4-ton | 19.5 | 8.5 | 23,200 Btu/h | 2 |
4SHP18LX136P | Ducted | 2-ton | 16–19 | 7.8–8.5 | 10,900–19,600 Btu/h | 319 |
4SHP17LE118P-**A | Ducted | 1.5-ton | 15.2–16.8 | 7.8–8.5 | 7,500–9,700 Btu/h | 662 |
4SHP17LE148P-**A | Ducted | 4-ton | 15.2–15.8 | 8–8.5 | 24,200–26,000 Btu/h | 452 |
4SHP17LE142P-**A | Ducted | 3.5-ton | 15.2–15.6 | 7.8–8.3 | 10,400–22,000 Btu/h | 170 |
4SHP17LE124P-**A | Ducted | 2-ton | 15.2–17 | 7.8–8.2 | 10,200–11,500 Btu/h | 635 |
4SHP18LX160P | Ducted | 4-ton | 16–17.5 | 7.8 | 26,200–27,000 Btu/h | 36 |
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.