Outdoor unit · ENERGY STAR data November 12, 2026

A7HP14F48P-**A: R-454B heat pump

Sold as Airease, Armstrong Air. R-454B Ducted split system, 4-ton class, in 38 ENERGY STAR certified pairings with 5 indoor unit models.

Refrigerant
R-454B (GWP 470)
Rated cooling
48,000 Btu/h
SEER2 range
15.2–15.5
HSPF2 range
7.8–8.2
Heat at 5°F
23,400–24,600 Btu/h
Cold-climate pairings
0 of 38
Compressor
Single stage
First certified
2025-10-27

This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: A7HP14F Series. ENERGY STAR partner: Lennox Industries.

Certified indoor matches

Top 30 of 38 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
7AH2AV48PXC**
—15.512.88.224,200 Btu/hNo215747173
7AH2AV60PXC**
—15.5138.223,400 Btu/hNo215747174
7AH2AV48PXC**
—15.512.88.224,200 Btu/hNo215747094
7AH2AV60PXC**
—15.5138.223,400 Btu/hNo215747095
7AH2AE48PX-**
—15.212.48.224,600 Btu/hNo215747171
7AH2AE48PX-**
—15.212.48.224,600 Btu/hNo215747092
7E[C,U]60CX-**+TDR
A80UH2E110C20*15.212.88.124,200 Btu/hNo215747219
7E[C,U]60CX-**+TDR
A80UH2E110C20*15.212.88.124,200 Btu/hNo215747140
7E[C,U]60CX-**+TDR
A97UH2E090C16S*15.212.8824,200 Btu/hNo215747244
7E[C,U]60CX-**+TDR
A96UH1E090C16S*15.212.8824,200 Btu/hNo215747246
7E[C,U]60CX-**+TDR
A80UH2E110C16*15.213823,800 Btu/hNo215747218
7E[C,U]60CX-**+TDR
A80UH1E090C20*15.212.8824,200 Btu/hNo215747223
7E[C,U]60CX-**+TDR
A80UH1E110C20*15.212.8824,000 Btu/hNo215747224
7E[C,U]60CX-**+TDR
A93UH1E090C16A*15.212.8824,200 Btu/hNo215747225
7E[C,U]60CX-**+TDR
A93UH1E110C16A*15.212.8823,800 Btu/hNo215747226
7E[C,U]60CX-**+TDR
A93UH1E110C20A*15.212.8824,000 Btu/hNo215747227
7E[C,U]60CX-**+TDR
A80US2V080C20X*15.212.6824,200 Btu/hNo215747229
7E[C,U]60CX-**+TDR
A80US2V100C20X*15.212.8824,000 Btu/hNo215747231
7E[C,U]60CX-**+TDR
A80US2V110C20*15.212.8824,000 Btu/hNo215747232
7E[C,U]60CX-**+TDR
80G2UH110CV20*15.212.8824,000 Btu/hNo216779559
7E[C,U]60CX-**+TDR
A80UH2E110C16*15.213823,800 Btu/hNo215747139
7E[C,U]60CX-**+TDR
A80UH1E090C20*15.212.8824,200 Btu/hNo215747144
7E[C,U]60CX-**+TDR
A80UH1E110C20*15.212.8824,000 Btu/hNo215747145
7E[C,U]60CX-**+TDR
A97UH2E090C16S*15.212.8824,200 Btu/hNo215747165
7E[C,U]60CX-**+TDR
A96UH1E090C16S*15.212.8824,200 Btu/hNo215747167
7E[C,U]60CX-**+TDR
A93UH1E090C16A*15.212.8824,200 Btu/hNo215747146
7E[C,U]60CX-**+TDR
A93UH1E110C16A*15.212.8823,800 Btu/hNo215747147
7E[C,U]60CX-**+TDR
A80US2V080C20X*15.212.6824,200 Btu/hNo215747150
7E[C,U]60CX-**+TDR
A80US2V100C20X*15.212.8824,000 Btu/hNo215747152
7E[C,U]60CX-**+TDR
A80US2V110C20*15.212.8824,000 Btu/hNo215747153
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-454B 4-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
BOHA-60MTB-M18SBosch16–19.58.1–10.131,000–45,000 Btu/h24
MDV-V48WMN10TMidea16–208.9–10.135,000–41,000 Btu/h7
MDV-V60WMN10T(B)Midea16–19.58.1–10.131,000–45,000 Btu/h22
249VAN048**AA*Bryant15.2–198.5–1036,000–41,500 Btu/h517
27VPA948A*030*Carrier15.2–198.5–1036,000–41,500 Btu/h534
5A6V0X48A1American Standard19.4–20.89.4–1032,600–34,800 Btu/h137
5TWV0X48A1Trane19.4–20.89.4–1032,600–34,800 Btu/h137
EODA19H-4860AB*Ecoer15.2–198.3–1028,000–38,500 Btu/h59

All 274 R-454B 4-ton units

More Airease R-454B units

Next step