Outdoor unit · ENERGY STAR data November 12, 2026

249VAN048**AA*: R-454B heat pump

Sold as Bryant. R-454B Ducted split system, 4-ton class, in 517 ENERGY STAR certified pairings with 38 indoor unit models.

Refrigerant
R-454B (GWP 470)
Rated cooling
47,000 Btu/h
SEER2 range
15.2–19
HSPF2 range
8.5–10
Heat at 5°F
36,000–41,500 Btu/h
Cold-climate pairings
517 of 517
Compressor
Continuously variable
First certified
2026-09-16

This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: Preferred 19 SEER2 VS HP. ENERGY STAR partner: Carrier Corporation.

Certified indoor matches

Top 30 of 517 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
FT5ANBD60L*
—1912.51036,000 Btu/hYes217914936
FG5ANBD60L*
—1912.51036,000 Btu/hYes217914937
PF5TNBD60L*
—1912.51036,000 Btu/hYes217914938
FT5BD6021X*
—1913.51038,500 Btu/hYes218695554
FT5BD4821X*
—19139.538,500 Btu/hYes218695538
FT5AN(B,X)C48L*
—1812936,400 Btu/hYes217914920
FG5ANXC48L*
—1812936,400 Btu/hYes217914921
PF5TNXC48L*
—1812936,400 Btu/hYes217914922
CAA**6121AM*
83*SB60080M21***17.511.5936,800 Btu/hYes217929535
CVAMA6021XMA*
926TC66100V21***17129.540,000 Btu/hYes217916163
CVAMA6021XMA*
927TA66100V21***17129.540,000 Btu/hYes217916202
CVAVA6021XMA*
926TC66100V21***17129.540,000 Btu/hYes217917324
CVAVA6021XMA*
927TA66100V21***17129.540,000 Btu/hYes217917371
CVAVA6121XMA*
88*TB60090C21***1711.59.540,500 Btu/hYes217917488
CVAVA6121XMA*
88*TB60110C21***1711.79.540,500 Btu/hYes217917501
CVAVA6124XMA*
82*SB66110V21***17129.540,500 Btu/hYes217917827
CVAVA6121XMA*
83*SB60080M21***17129.540,000 Btu/hYes217917449
CVAVA6124XMA*
82*TB66135V24***17129.540,500 Btu/hYes217917931
F55AA*C48L*
—17129.536,000 Btu/hYes217931449
CAA**6121AM*
926TC66100V21***1711.59.536,600 Btu/hYes217929821
CAA**6121AM*
927TA66100V21***1711.59.536,600 Btu/hYes217929860
CVAVA6121XMA*
83*CB60080C21***1712940,500 Btu/hYes217917384
CAA**6121AM*
83*CB60080C21***1711.5936,600 Btu/hYes217929457
CAA**6121AM*
88*TB60090C21***1711.5936,800 Btu/hYes217929574
CAA**6121AM*
88*TB60110C21***1711937,000 Btu/hYes217929587
CAA**6121AM*
82*TB60090V21***1711937,000 Btu/hYes217929613
CAA**6121AM*
935SB66100M21***1711937,000 Btu/hYes217929730
CAA**6121AM*
986TD66100C21***1711937,200 Btu/hYes217929756
CAA**4821AM*
83*SB60080M21***1711936,600 Btu/hYes217928650
CAA**6121AM*
987TA66100C21***1711937,200 Btu/hYes217929782
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-454B 4-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
BOHA-60MTB-M18SBosch16–19.58.1–10.131,000–45,000 Btu/h24
MDV-V48WMN10TMidea16–208.9–10.135,000–41,000 Btu/h7
MDV-V60WMN10T(B)Midea16–19.58.1–10.131,000–45,000 Btu/h22
27VPA948A*030*Carrier15.2–198.5–1036,000–41,500 Btu/h534
5A6V0X48A1American Standard19.4–20.89.4–1032,600–34,800 Btu/h137
5TWV0X48A1Trane19.4–20.89.4–1032,600–34,800 Btu/h137
EODA19H-4860AB*Ecoer15.2–198.3–1028,000–38,500 Btu/h59
FRP19AY48AJVCFriedrich18–198.5–1034,800–42,000 Btu/h28

All 274 R-454B 4-ton units

More Bryant R-454B units

Next step

Some links are affiliate links; we may earn a commission at no cost to you. Disclosure.