Refrigerant Finder
Lennox · ENERGY STAR data November 12, 2026

Lennox heat pump refrigerants: R-454B / R-32 / R-410A

Lennox has 158 ENERGY STAR certified outdoor unit models (55 R-454B, 47 R-32, 56 R-410A) in 9,237 certified systems.

R-454B 55 (35%)R-32 47 (30%)R-410A 56 (35%)
Main refrigerant
R-410A
Outdoor models
158
Ducted / mini / packaged
48 / 92 / 18
Certified systems
9,237

Some of these outdoor units are also listed under Allied Commercial.

Which refrigerant a Lennox system uses depends on the exact outdoor model, not the brand. Check the model below or in the lookup, and make sure the indoor coil or air handler on your quote is certified with it.

Lennox R-454B outdoor units

Outdoor unitTypeSizeSEER2HSPF2Heat at 5°FCertified pairings
SL22KLV-024-230A**Ducted2-ton16.9–20.58.2–10.517,700–24,200 Btu/h107
SL22KLV-036-230A**Ducted3-ton16.5–20.58–10.524,400–34,000 Btu/h80
EL21KLV-036-230A**Ducted3-ton15.2–208.5–10.418,400–25,400 Btu/h299
EL21KLV-024-230A**Ducted2-ton15.2–218.1–10.213,900–18,600 Btu/h178
VPC030H5M-3PMini/multi-split30,000 Btu17.8–209.8–10.130,000 Btu/h3
VPC030H5M-3P*Mini/multi-split30,000 Btu17.8–209.8–10.130,000 Btu/h3
VPC036H5M-3PMini/multi-split36,000 Btu17.8–209.6–10.134,000 Btu/h3
VPC036H5M-3P*Mini/multi-split36,000 Btu17.8–209.6–10.134,000 Btu/h3
VPC048H5M-3PMini/multi-split48,000 Btu17.6–2010–10.135,000–40,000 Btu/h3
VPC048H5M-3P*Mini/multi-split48,000 Btu17.6–2010–10.135,000–40,000 Btu/h3
VPC060H5M-3PMini/multi-split60,000 Btu17–19.59.2–10.142,000 Btu/h3
VPC060H5M-3P*Mini/multi-split60,000 Btu17–19.59.2–10.142,000 Btu/h3
EL18KSLV-024-230A**Ducted2-ton15.2–18.58.5–1020,000–23,400 Btu/h205
VPC024H5M-3PMini/multi-split24,000 Btu17–18.59–1020,000 Btu/h3
VPC024H5M-3P*Mini/multi-split24,000 Btu17–18.59–1020,000 Btu/h3
VPC018H5M-3PMini/multi-split18,000 Btu17–17.59–1018,000 Btu/h3
VPC018H5M-3P*Mini/multi-split18,000 Btu17–17.59–1018,000 Btu/h3
SL22KLV-048-230A**Ducted4-ton18–20.57.8–9.837,000–46,500 Btu/h38
SL22KLV-060-230A**Ducted4.5-ton18.2–21.18.2–9.635,400–45,500 Btu/h33
EL21KLV-048-230A**Ducted4-ton15.7–20.57.8–9.629,000–39,500 Btu/h191
EL18KSLV-036-230A**Ducted3-ton15.2–19.38.1–9.627,600–30,800 Btu/h355
EL18KSLV-060-230A**Ducted4-ton15.2–18.38.1–9.639,000–45,000 Btu/h353
ML15KSPV-030-230A**Ducted2.5-ton15.2–16.78.5–9.219,000–20,000 Btu/h16
EL21KLV-060-230A**Ducted4.5-ton16–20.58.2–931,000–38,500 Btu/h106
EL19KPV-024-230A**Ducted2-ton15.2–207.8–911,700–17,000 Btu/h221

All 55 Lennox R-454B outdoor units

Lennox R-32 outdoor units

Outdoor unitTypeSizeSEER2HSPF2Heat at 5°FCertified pairings
MWLD015S6S-1PMini/multi-split15,000 Btu231115,600 Btu/h1
MWPD015S6S-1PMini/multi-split15,000 Btu231115,600 Btu/h1
VPD060H6M-5PMini/multi-split60,000 Btu19–2310.5–1147,000 Btu/h3
VPD036S6M-5PMini/multi-split36,000 Btu19–2210–1131,000 Btu/h3
MMLD030S6S-1PMini/multi-split30,000 Btu19–22.89.7–10.734,000–35,000 Btu/h3
MMLD009S6S-1PMini/multi-split9,000 Btu18.9–22.19.5–10.68,000–9,600 Btu/h5
MMLD036S6S-1PMini/multi-split36,000 Btu18.7–229–10.636,000–40,000 Btu/h4
MWLD009S6S-1PMini/multi-split9,000 Btu2510.58,500 Btu/h1
MWMD009S6-1PMini/multi-split9,000 Btu2510.58,500 Btu/h2
MWPD009S6S-1PMini/multi-split9,000 Btu2510.58,500 Btu/h1
MWLD012S6S-1PMini/multi-split12,000 Btu2410.59,000 Btu/h1
MWPD012S6S-1PMini/multi-split12,000 Btu2410.59,000 Btu/h1
MMLD020S6M-1PMini/multi-split18,000 Btu20.5–239.5–10.522,000 Btu/h3
VPD048S6M-5PMini/multi-split48,000 Btu19–21.310–10.538,000 Btu/h3
MMLD024S6M-1PMini/multi-split24,000 Btu20–239.5–10.425,000 Btu/h3
MMLD012S6S-1PMini/multi-split12,000 Btu18.6–229.5–10.410,400–11,200 Btu/h5
MMLD048S6S-1PMini/multi-split48,000 Btu18–209.5–10.452,000–54,000 Btu/h3
MMLD024S6S-1PMini/multi-split24,000 Btu17.3–228.8–10.224,200–27,000 Btu/h4
VPD060S6M-5PMini/multi-split60,000 Btu16.5–209.5–10.247,000 Btu/h3
MMLD030S6M-1PMini/multi-split30,000 Btu20–22.59.5–1028,600 Btu/h3
MWHD015S6S-1PMini/multi-split15,000 Btu21.51010,500 Btu/h1
MWLD018S6S-1PMini/multi-split18,000 Btu219.714,300 Btu/h1
MWMD018S6-1PMini/multi-split18,000 Btu219.714,300 Btu/h2
MWPD018S6S-1PMini/multi-split18,000 Btu219.714,300 Btu/h1
MMLD018S6S-1PMini/multi-split18,000 Btu17–23.88.5–9.618,100–20,000 Btu/h8

All 47 Lennox R-32 outdoor units

Lennox R-410A outdoor units

Outdoor unitTypeSizeSEER2HSPF2Heat at 5°FCertified pairings
MPC009S4S-1PMini/multi-split9,000 Btu19.2–26.510–13.67,400–8,000 Btu/h12
MLB009S4S-1PMini/multi-split9,000 Btu20.2–28.110.2–1210,000–10,800 Btu/h9
MLB048S4S-1PMini/multi-split48,000 Btu171250,000 Btu/h1
MLB048S4S-2PMini/multi-split48,000 Btu16.8–179.8–1248,000–50,000 Btu/h6
MLB024S4S-1PMini/multi-split24,000 Btu18.4–21.59.1–11.521,200–27,000 Btu/h14
LISH024000P431-DMini/multi-split24,000 Btu19–21.59.7–11.218,200–20,000 Btu/h4
MLB018S4S-1PMini/multi-split18,000 Btu17.6–21.59.2–11.216,000–18,000 Btu/h13
MPC024S4S-1PMini/multi-split24,000 Btu18–228.1–1114,000–20,000 Btu/h13
MLB036S4S-2PMini/multi-split36,000 Btu16.5–19.410–1136,000–40,000 Btu/h6
MLB036S4S-1PMini/multi-split36,000 Btu16.51136,000 Btu/h1
MPC012S4S-1PMini/multi-split12,000 Btu18.8–24.69.9–10.78,000–8,400 Btu/h12
MPC018S4S-1PMini/multi-split18,000 Btu17.8–23.59.3–10.711,300–13,000 Btu/h13
LISH018000P431-DMini/multi-split18,000 Btu20–2310–10.612,700–13,000 Btu/h3
MLB030S4M-1PMini/multi-split30,000 Btu20–239.5–10.625,000 Btu/h4
MPC018S4M-1PMini/multi-split18,000 Btu19–22.99.8–10.512,600–13,300 Btu/h3
MLB012S4S-1PMini/multi-split12,000 Btu19.5–25.510–10.411,300–12,100 Btu/h12
LISH012000P431-DMini/multi-split12,000 Btu19–22.710–10.38,000–8,400 Btu/h2
MLB036S4M-1PMini/multi-split36,000 Btu18.8–22.210–10.333,000–36,000 Btu/h3
MPC024S4M-1PMini/multi-split24,000 Btu16–24.68.6–1017,800–19,000 Btu/h3
MPC012S4S-1LMini/multi-split12,000 Btu22.4–23.57.8–105,600–6,800 Btu/h3
LISH048000P431-DMini/multi-split48,000 Btu18.91035,000 Btu/h1
MLB048S4M-2PMini/multi-split48,000 Btu20.9–21.89–9.842,500–45,000 Btu/h3
MLB018S4M-1PMini/multi-split18,000 Btu19–21.79.3–9.819,000–19,700 Btu/h3
MPC048S4S-1PMini/multi-split48,000 Btu18.99.735,000 Btu/h3
MPC036S4M-1PMini/multi-split36,000 Btu23.99.525,200 Btu/h1

All 56 Lennox R-410A outdoor units

Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Next step