Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

VPD036S6M-5P: R-32 mini-split heat pump

Sold as Lennox. R-32 Mini-split or multi-split, 36,000 Btu class, in 3 ENERGY STAR certified pairings with 0 indoor unit models.

Refrigerant
R-32 (GWP 675)
Rated cooling
38,000 Btu/h
SEER2 range
19–22
HSPF2 range
10–11
Heat at 5°F
31,000 Btu/h
Cold-climate pairings
3 of 3
Compressor
Continuously variable
First certified
2026-03-26

This unit uses R-32, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-32, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: DVM S Mini. ENERGY STAR partner: Lennox Industries.

Certified indoor matches

Top 3 of 3 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
—
LENNOX
—2213.51131,000 Btu/hYes216054505
—
LENNOX
—20.512.810.531,000 Btu/hYes217169770
—
LENNOX
—19121031,000 Btu/hYes216054509
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-32 36,000 Btu units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
PAS-36BLFASDQ1Hitachi16.5–20.510.2–11.836,600–39,500 Btu/h4
PAS-36BUFASDQ1Hitachi18–2110.4–11.828,600–35,000 Btu/h4
YPAS36BLFASDQ1York16.5–20.510.2–11.836,600–39,500 Btu/h3
YPAS36BUFASDQ1York18–2110.4–11.828,600–35,000 Btu/h4
AB-GTMH36-230VOArmbridge21.5–2410–1133,000–34,000 Btu/h3
ACIQ-36Z-E-HH-M4ACiQ21.5–2410–1133,000–34,000 Btu/h3
AM036FCMDCGSamsung19–2210–1131,000 Btu/h3
AM036HCMDCSSamsung19–2210–1131,000 Btu/h3

All 150 R-32 36,000 Btu units