Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

ML15KSPV-030-230A**: R-454B heat pump

Sold as Lennox. R-454B Ducted split system, 2.5-ton class, in 16 ENERGY STAR certified pairings with 10 indoor unit models.

Refrigerant
R-454B (GWP 470)
Rated cooling
29,300 Btu/h
SEER2 range
15.2–16.7
HSPF2 range
8.5–9.2
Heat at 5°F
19,000–20,000 Btu/h
Cold-climate pairings
0 of 16
Compressor
Continuously variable
First certified
2026-03-11

This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: ML15KSPV SERIES, Merit ML15KSPV SERIES, ML15KSPV Series. ENERGY STAR partner: Lennox Industries.

Certified indoor matches

Top 16 of 16 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
CBK48MVT-030-230-**
—16.711.49.219,200 Btu/hNo218616036
CBK48MVT-036-230-**
—16.611.49.219,300 Btu/hNo218616037
CBK47UHET-030-230-**
—16.611.19.219,300 Btu/hNo218616035
CK40[C,U]T-36B-**+TDR
ML180UH070V36B*16.4118.520,000 Btu/hNo218617676
CBK45UHET-036-230-**
—16.311919,500 Btu/hNo218616033
CBK45UHET-030-230-**
—16.2118.719,500 Btu/hNo218616032
CK40HT-36C-**+TDR
EL297UH110XV48C*16.2118.719,700 Btu/hNo218617680
CK40HT-36C-**+TDR
EL297UH090XV36C*16.2118.719,700 Btu/hNo218617678
CK40HT-36C-**+TDR
SLP99UH090XV36C*16.2118.719,700 Btu/hNo218617675
CK40HT-36C-**+TDR
ML297UH090XV36C*16.2118.719,700 Btu/hNo218730793
CK40[C,U]T-36B-**+TDR
SL280UH090V36B*16.2118.520,000 Btu/hNo218617677
CK40DT-42B-**+TDR
EL297DF045XV36B*16.1118.719,700 Btu/hNo218617682
CBK45UHVT-036-230-**
—1611.28.919,400 Btu/hNo218616034
CBK45UHVT-030-230-**
—16118.819,000 Btu/hNo218082939
CK40HT-36C-**+TDR
EL280UH110E48C*15.3118.619,800 Btu/hNo218617679
CK40HT-36C-**+TDR
ML193UH110XE48C*15.2118.619,800 Btu/hNo218617681
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-454B 2.5-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
37MUHAQ30AA3Bryant, Carrier +3 more15.3–17.59.3–10.830,400–33,200 Btu/h35
ACIQ-30-HPDACiQ, 1HVAC15.3–17.58.7–10.828,000–33,200 Btu/h18
AHU3G-30HFN-BAproDr, ApooDr16.3–17.29.5–10.831,000–33,200 Btu/h3
AUO19-30N2-M3HAI Air Conditioning15.3–17.59.3–10.830,400–33,200 Btu/h7
BNG3A30UCNBlueridge15.3–17.29.3–10.830,400–33,200 Btu/h5
BZ33-INV30OUT2-454-G3-JBreeze3316–17.29.6–10.832,000–33,200 Btu/h4
CH-PQ33-230VOCooper&Hunter16–17.59.2–10.830,000–33,200 Btu/h6
CPH3-30CD(O)ComfortStar16.8–17.510–10.832,000–33,200 Btu/h3

All 176 R-454B 2.5-ton units

More Lennox R-454B units

Next step