Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

EL16KP1-042-230A**: R-454B heat pump

Sold as Lennox. R-454B Ducted split system, 3.5-ton class, in 85 ENERGY STAR certified pairings with 10 indoor unit models.

Refrigerant
R-454B (GWP 470)
Rated cooling
41,500 Btu/h
SEER2 range
15.2–15.5
HSPF2 range
7.8–8.2
Heat at 5°F
19,300–20,800 Btu/h
Cold-climate pairings
0 of 85
Compressor
Single stage
First certified
2025-10-27

This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: ELITE EL16KP1 Series, Elite EL16KP1 SERIES. ENERGY STAR partner: Lennox Industries.

Certified indoor matches

Top 30 of 85 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
CBK47UHET-042-230-**
—15.512.88.220,000 Btu/hNo215740156
CBK47UHET-048-230-**
—15.512.88.220,400 Btu/hNo215740157
CBK47UHET-048-460-**
—15.512.88.220,400 Btu/hNo217595433
CK40[C,U]T-49C-**+TDR
EL280UH110E60C*15.513.2819,400 Btu/hNo215740205
CK40[C,U]T-49C-**+TDR
EL280UH110XE60C*15.513.2819,400 Btu/hNo215740206
CK40[C,U]T-49C-**+TDR
ML180UH090E60C*15.513819,700 Btu/hNo215740214
CK40[C,U]T-49C-**+TDR
ML180UH110V60C*15.513819,500 Btu/hNo215740216
CK40[C,U]T-48C-**+TDR
ML180UH110V60C*15.5137.820,400 Btu/hNo215740176
CK40[C,U]T-48C-**+TDR
ML180UH110XE60C*15.5137.820,400 Btu/hNo215740177
CK40[C,U]T-48C-**+TDR
ML193UH110XE48C*15.5137.820,200 Btu/hNo215740180
CK40[C,U]T-48C-**+TDR
ML196UH110XE60C*15.512.87.820,400 Btu/hNo215740185
CK40[C,U]T-48C-**+TDR
SL280UH080NV60C*15.5137.820,400 Btu/hNo215740188
CK40[C,U]T-48C-**+TDR
SL280UH090V60C*15.512.87.820,600 Btu/hNo215740189
CK40[C,U]T-48C-**+TDR
SL280UH090XV60C*15.512.87.820,600 Btu/hNo215740190
CBK45UHVT-042-230-**
—15.512.87.820,600 Btu/hNo215740154
CK40[C,U]T-48C-**+TDR
EL280UH110E60C*15.5137.820,400 Btu/hNo215740165
CK40[C,U]T-48C-**+TDR
EL280UH110XE60C*15.5137.820,400 Btu/hNo215740166
CK40[C,U]T-48C-**+TDR
EL280UH110E48C*15.513.27.820,200 Btu/hNo215740164
CK40[C,U]T-48C-**+TDR
EL196UH110XE60C*15.512.87.820,400 Btu/hNo215740163
CK40[C,U]T-48C-**+TDR
ML180UH090E60C*15.5137.820,600 Btu/hNo215740174
CK40[C,U]T-48C-**+TDR
ML180UH110E60C*15.5137.820,400 Btu/hNo215740175
CK40[C,U]T-49C-**+TDR
EL196UH110XE60C*15.5137.819,400 Btu/hNo215740203
CK40[C,U]T-49C-**+TDR
EL280UH110E48C*15.5137.819,300 Btu/hNo215740204
CK40HT-42B-**+TDR
ML180UH090E48B*15.513.27.819,400 Btu/hNo215740272
CK40HT-42B-**+TDR
ML180UH090XE48B*15.513.27.819,400 Btu/hNo215740274
CK40[C,U]T-49C-**+TDR
EL297UH090XV48C*15.512.87.819,600 Btu/hNo215740209
CK40[C,U]T-49C-**+TDR
EL297UH110XE60C*15.512.87.819,900 Btu/hNo215740211
CK40[C,U]T-49C-**+TDR
ML180UH110E60C*15.5137.819,500 Btu/hNo215740215
CK40[C,U]T-49C-**+TDR
ML180UH110XE60C*15.5137.819,500 Btu/hNo215740217
CK40[C,U]T-49C-**+TDR
ML193UH110XE48C*15.5137.819,300 Btu/hNo215740220
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-454B 3.5-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
BOVA-60MTB-M19EBosch15.2–198.5–1040,500–55,000 Btu/h25
BOVB-60MTB-M19EBosch15.2–198.5–1040,500–55,000 Btu/h25
MOVA-60HDN10-M20GMidea15.2–198.5–1040,500–55,000 Btu/h25
MOVC-60HDN10-M20GMidea15.2–198.5–1040,500–55,000 Btu/h25
RD18AY48AJVCFriedrich, Russell +3 more16–198.1–1030,800–38,000 Btu/h674
ACIQ-42-HPDACiQ, 1HVAC15.7–16.78.8–9.542,000–46,000 Btu/h3
BOVA-60RTB-M20SBosch16–18.58.5–9.531,000–38,500 Btu/h25
BOVB-60RTB-M20SBosch16–18.58.5–9.531,000–38,500 Btu/h25

All 94 R-454B 3.5-ton units

More Lennox R-454B units