Outdoor unit · ENERGY STAR data November 12, 2026
EL19KPV-036-230A**: R-454B heat pump
Sold as Lennox. R-454B Ducted split system, 3-ton class, in 154 ENERGY STAR certified pairings with 12 indoor unit models.
- Refrigerant
- R-454B (GWP 470)
- Rated cooling
- 34,800 Btu/h
- SEER2 range
- 15.5–19
- HSPF2 range
- 7.8–8.5
- Heat at 5°F
- 14,600–17,700 Btu/h
- Cold-climate pairings
- 0 of 154
- Compressor
- Continuously variable
- First certified
- 2025-07-03
This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.
Series: Elite EL19KPV SERIES, Elite EL19KPV Series. ENERGY STAR partner: Lennox Industries.
Certified indoor matches
Top 30 of 154 pairings by SEER2. The AHRI number links to the ENERGY STAR record.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat at 5°F | Cold climate | AHRI ref # |
|---|---|---|---|---|---|---|---|
CK40[C,U]T-36B-**+TDR | EL280UH090E36B* | 19 | 11.2 | 8.2 | 14,800 Btu/h | No | 217194202 |
CK40[C,U]T-36A-**+TDR | EL280UH045E36A* | 19 | 11 | 8.2 | 15,100 Btu/h | No | 217194224 |
CK40[C,U]T-36B-**+TDR | EL280UH045E36A* | 19 | 11 | 8.2 | 15,100 Btu/h | No | 217507587 |
CK40[C,U]T-36A-**+TDR | SL280UH060NV36A* | 18.5 | 11 | 8.2 | 15,000 Btu/h | No | 217194193 |
CK40[C,U]T-36B-**+TDR | ML180UH070V36B* | 18.5 | 11.2 | 8.2 | 14,900 Btu/h | No | 217194206 |
CK40[C,U]T-36B-**+TDR | ML180UH070V48B* | 18.5 | 11.2 | 8.2 | 14,900 Btu/h | No | 217194207 |
CK40[C,U]T-36B-**+TDR | ML193UH070XE36B* | 18.5 | 11 | 8.2 | 14,800 Btu/h | No | 217194214 |
CK40[C,U]T-36A-**+TDR | EL180UH040NE36A* | 18.5 | 11 | 8.2 | 14,900 Btu/h | No | 217194222 |
CK40[C,U]T-36A-**+TDR | EL180UH060NE36A* | 18.5 | 11 | 8.2 | 14,900 Btu/h | No | 217194223 |
CK40[C,U]T-36A-**+TDR | EL280UH070E36A* | 18.5 | 11 | 8.2 | 14,800 Btu/h | No | 217194225 |
CK40[C,U]T-36A-**+TDR | EL280UH070XE36A* | 18.5 | 11 | 8.2 | 14,800 Btu/h | No | 217194226 |
CK40[C,U]T-36A-**+TDR | ML180UH045E36A* | 18.5 | 11 | 8.2 | 14,900 Btu/h | No | 217194228 |
CK40[C,U]T-36A-**+TDR | ML180UH045XE36A* | 18.5 | 11 | 8.2 | 14,900 Btu/h | No | 217194230 |
CK40[C,U]T-36B-**+TDR | EL180UH060NE36A* | 18.5 | 11 | 8.2 | 14,900 Btu/h | No | 217507586 |
CK40[C,U]T-36B-**+TDR | EL280UH070E36A* | 18.5 | 11.2 | 8.2 | 14,800 Btu/h | No | 217507588 |
CK40[C,U]T-36C-**+TDR | EL297UH090XV36C* | 18.5 | 11.2 | 8.2 | 14,800 Btu/h | No | 218073907 |
CK40[C,U]T-36C-**+TDR | ML180UH110V60C* | 18.5 | 11.2 | 8.2 | 14,900 Btu/h | No | 218073900 |
CK40[C,U]T-36C-**+TDR | EL297UH070XV36B* | 18.5 | 11 | 8.2 | 15,000 Btu/h | No | 218073866 |
CK40[C,U]T-36C-**+TDR | SLP99UH090XV36C* | 18.5 | 11.2 | 8.2 | 14,900 Btu/h | No | 218073861 |
CK40[C,U]T-36C-**+TDR | ML297UH110XV60C* | 18.5 | 11.2 | 8.2 | 15,200 Btu/h | No | 218732593 |
CK40[C,U]T-36C-**+TDR | ML197UH060XE36B* | 18 | 11.2 | 8.5 | 15,000 Btu/h | No | 218747724 |
CK40[C,U]T-36B-**+TDR | ML197UH060XE36B* | 18 | 11 | 8.5 | 15,400 Btu/h | No | 218747714 |
CBK48MVT-036-230-** | — | 18 | 11.2 | 8.4 | 17,700 Btu/h | No | 217194183 |
CK40[C,U]T-36B-**+TDR | SL280UH080NV48B* | 18 | 11 | 8.2 | 15,100 Btu/h | No | 217194184 |
CK40[C,U]T-36B-**+TDR | SL280UH090V36B* | 18 | 11.2 | 8.2 | 14,900 Btu/h | No | 217194185 |
CK40[C,U]T-36B-**+TDR | SL280UH090V48B* | 18 | 11 | 8.2 | 15,000 Btu/h | No | 217194186 |
CK40[C,U]T-36B-**+TDR | SL280UH090XV48B* | 18 | 11 | 8.2 | 15,000 Btu/h | No | 217194187 |
CK40[C,U]T-36B-**+TDR | EL297UH070XV36B* | 18 | 11 | 8.2 | 15,100 Btu/h | No | 217194192 |
CK40[C,U]T-36B-**+TDR | SLP99UH070XV36B* | 18 | 11 | 8.2 | 15,000 Btu/h | No | 217194190 |
CK40[C,U]T-36B-**+TDR | EL195UH040NE36B* | 18 | 11 | 8.2 | 14,900 Btu/h | No | 217194198 |
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.
Other R-454B 3-ton units
| Outdoor unit | Brand | SEER2 | HSPF2 | Heat at 5°F | Certified pairings |
|---|---|---|---|---|---|
MCY-MUB0368HS2P-UL | Toshiba Carrier | 16.6–29.7 | 8.2–12.2 | 21,000–28,200 Btu/h | 7 |
5A6V0X36A1 | American Standard | 19.2–21 | 9.4–10.5 | 23,800–25,400 Btu/h | 112 |
5TWV0X36A1 | Trane | 19.2–21 | 9.4–10.5 | 23,800–25,400 Btu/h | 112 |
D5CSHAH33AAK | Airquest, Arcoaire +11 more | 16.7–19.6 | 10–10.5 | 34,000–35,000 Btu/h | 25 |
SL22KLV-036-230A** | Lennox | 16.5–20.5 | 8–10.5 | 24,400–34,000 Btu/h | 80 |
A7CP21V36P-**A | Airease, Armstrong Air +1 more | 15.2–20 | 8.5–10.4 | 18,400–25,400 Btu/h | 529 |
EL21KLV-036-230A** | Lennox | 15.2–20 | 8.5–10.4 | 18,400–25,400 Btu/h | 299 |
NS21H36MA5-**A | GE | 15.2–20 | 8.5–10.4 | 18,400–24,400 Btu/h | 133 |