R-454B 3.5-ton heat pumps
94 ENERGY STAR certified R-454B outdoor unit models in the 3.5-ton class from 62 brands, in 9,343 certified systems. Sorted by best HSPF2 (heating efficiency).
- Outdoor models
- 94
- Best SEER2
- 19
- Best HSPF2
- 10
- With cold-climate pairings
- 43
| Outdoor unit | Brand | SEER2 | HSPF2 | Heat at 5°F | Cold-climate pairings | Certified pairings |
|---|---|---|---|---|---|---|
BOVA-60MTB-M19E | Bosch | 15.2–19 | 8.5–10 | 40,500–55,000 Btu/h | 25 | 25 |
BOVB-60MTB-M19E | Bosch | 15.2–19 | 8.5–10 | 40,500–55,000 Btu/h | 25 | 25 |
MOVA-60HDN10-M20G | Midea | 15.2–19 | 8.5–10 | 40,500–55,000 Btu/h | 25 | 25 |
MOVC-60HDN10-M20G | Midea | 15.2–19 | 8.5–10 | 40,500–55,000 Btu/h | 25 | 25 |
RD18AY48AJVC | Friedrich, Russell +3 more | 16–19 | 8.1–10 | 30,800–38,000 Btu/h | 666 | 674 |
BOVA-60RTB-M20S | Bosch | 16–18.5 | 8.5–9.5 | 31,000–38,500 Btu/h | 25 | 25 |
BOVB-60RTB-M20S | Bosch | 16–18.5 | 8.5–9.5 | 31,000–38,500 Btu/h | 25 | 25 |
MOVB-60HDN10-M20G | Midea | 16–18.5 | 8.5–9.5 | 31,000–38,500 Btu/h | 25 | 25 |
MOVD-60HDN10-M20G | Midea | 16–18.5 | 8.5–9.5 | 31,000–38,500 Btu/h | 25 | 25 |
ACIQ-42-HPD | ACiQ, 1HVAC | 15.7–16.7 | 8.8–9.5 | 42,000–46,000 Btu/h | 3 | 3 |
AUO19-42N2-M3H-S | AI Air Conditioning | 16.7 | 9.5 | 46,000 Btu/h | 1 | 1 |
ECUO-42H | Eco-air | 16.7 | 9.5 | 46,000 Btu/h | 1 | 1 |
HHS-42HD-B | Multi MFG | 16.7 | 9.5 | 46,000 Btu/h | 1 | 1 |
ML42HP230LMNTH-O | Mainline | 16.7 | 9.5 | 46,000 Btu/h | 2 | 2 |
MOX630-42HFN10-M3X-D | MDV | 15.7–16.7 | 8.8–9.5 | 42,000–46,000 Btu/h | 3 | 3 |
UHO42-NB-LD-Q | Mitsutomo | 16.7 | 9.5 | 46,000 Btu/h | 1 | 1 |
FRP17AY48AJVC | Friedrich | 15.2–16 | 8.5–9.5 | 33,200–37,600 Btu/h | 221 | 221 |
RP17AY48AJVC | Rheem, Ruud | 15.2–16 | 8.5–9.5 | 33,200–37,600 Btu/h | 222 | 222 |
SP17AY48AJVC | Sure | 15.2–16 | 8.5–9.5 | 33,200–37,600 Btu/h | 111 | 111 |
5A6H7048A1 | American Standard | 15.2–17.1 | 8.5–9.4 | 31,800–33,800 Btu/h | 61 | 231 |
5TWR7048A1 | Trane | 15.2–17.1 | 8.5–9.4 | 31,800–33,800 Btu/h | 61 | 231 |
5TWX7048A1 | Trane | 15.2–17.1 | 8.5–9 | 31,800–33,200 Btu/h | 56 | 220 |
HH860E2S12 | Coleman, Luxaire +3 more | 15.2–18 | 8.1–8.5 | 33,600–40,000 Btu/h | 15 | 2,092 |
5A6H5042A1 | American Standard | 15.2–17 | 7.8–8.5 | 18,700–20,000 Btu/h | 0 | 293 |
5TWR5042A1 | Trane | 15.2–17 | 7.8–8.5 | 18,700–20,000 Btu/h | 0 | 293 |
BOVA-60RXB-M15S | Bosch | 16–17 | 8.5 | 31,000–39,500 Btu/h | 19 | 19 |
BOVB-60RTB-M15S | Bosch | 16–17 | 8.5 | 31,000–39,500 Btu/h | 20 | 20 |
MOVB-60HDN10-M16G | Midea | 16–17 | 8.5 | 31,000–39,500 Btu/h | 19 | 19 |
MOVC-60HDN10-M16G | Midea | 16–17 | 8.5 | 31,000–39,500 Btu/h | 21 | 21 |
XD560E2D11 | Champion, Coleman +2 more | 16–17 | 8.5 | 32,200–39,500 Btu/h | 16 | 16 |
YD560E2D11 | York | 16–17 | 8.5 | 32,200–39,500 Btu/h | 4 | 4 |
5A6H6042A1 | American Standard | 15.2–16.5 | 7.8–8.5 | 18,700–19,900 Btu/h | 0 | 248 |
5TWR6042A1 | Trane | 15.2–16.5 | 7.8–8.5 | 18,700–19,900 Btu/h | 0 | 248 |
5TWX5042A1 | Trane | 15.2–16.5 | 7.8–8.5 | 18,700–20,000 Btu/h | 0 | 231 |
5A6H5048A1 | American Standard | 15.2–16 | 7.8–8.5 | 21,200–22,600 Btu/h | 0 | 167 |
5A6H6048A1 | American Standard | 15.2–16 | 7.8–8.5 | 21,800–22,600 Btu/h | 0 | 127 |
5TWR5048A1 | Trane | 15.2–16 | 7.8–8.5 | 21,200–22,600 Btu/h | 0 | 167 |
5TWR6048A1 | Trane | 15.2–16 | 7.8–8.5 | 21,800–22,600 Btu/h | 0 | 127 |
5TWX5048A1 | Trane | 15.2–16 | 7.8–8.5 | 21,400–22,600 Btu/h | 0 | 101 |
RD16AY48AJVC | Friedrich, Ruud +3 more | 16 | 8.1–8.5 | 22,000–25,800 Btu/h | 30 | 35 |
7HP14F42P-**A | Allied, Concord +2 more | 15.2–15.5 | 7.8–8.2 | 19,000–20,800 Btu/h | 0 | 188 |
A7HP14F42P-**A | Airease, Armstrong Air | 15.2–15.5 | 7.8–8.2 | 19,000–20,800 Btu/h | 0 | 128 |
EL16KP1-042-230A** | Lennox | 15.2–15.5 | 7.8–8.2 | 19,300–20,800 Btu/h | 0 | 85 |
ML14KP1-042-230A** | Lennox | 15.2–15.5 | 7.8–8.2 | 19,300–20,800 Btu/h | 0 | 85 |
NS16H42SA5-**A | GE | 15.2–15.5 | 7.8–8.2 | 19,400–20,800 Btu/h | 0 | 42 |
5HPL5048A1 | American Standard, Trane | 15.2–16 | 8.1 | 37,000–38,000 Btu/h | 8 | 8 |
5TWX6042A1 | Trane | 15.2–16 | 7.8–8.1 | 18,700–19,800 Btu/h | 0 | 188 |
A5HP5042A1 | Ameristar, RunTru | 15.2–16 | 7.8–8.1 | 18,800–20,000 Btu/h | 0 | 250 |
A5HP5048A1 | Ameristar, RunTru | 15.2–16 | 7.8–8.1 | 21,400–22,600 Btu/h | 0 | 156 |
DRHP15B42AJ2AN | DuraSTAR | 15.2–16 | 7.8–8.1 | 18,700–19,300 Btu/h | 49 | 50 |
FOP1542TJAYNA | Fujitsu | 15.2–16 | 7.8–8.1 | 18,700–19,300 Btu/h | 56 | 57 |
FRP15AY42AJ2N | Friedrich | 15.2–16 | 7.8–8.1 | 18,400–19,300 Btu/h | 118 | 129 |
FWP15AY42AJ2N | Friedrich | 15.2–16 | 7.8–8.1 | 18,700–19,300 Btu/h | 116 | 127 |
MLP15AY42AJ2N | Mainline | 16 | 8.1 | 18,400–19,300 Btu/h | 58 | 58 |
MPP15AY42AJ2N | Mainline | 15.2–16 | 8.1 | 18,700–19,300 Btu/h | 53 | 53 |
N5HP5042A1 | American Standard, Trane | 15.2–16 | 7.8–8.1 | 19,100–19,900 Btu/h | 0 | 144 |
N5HP5048A1 | American Standard, Trane | 15.2–16 | 7.8–8.1 | 22,000–22,400 Btu/h | 0 | 56 |
RP15AY42AJ2N | Ruud, Rheem | 15.2–16 | 7.8–8.1 | 18,200–21,000 Btu/h | 120 | 151 |
SP15AY42AJ2N | Russell, Sure | 15.2–16 | 7.8–8.1 | 18,400–19,300 Btu/h | 120 | 132 |
THH48HES2NAGOH24 | TCL | 15.2–16 | 8.1 | 37,000–38,000 Btu/h | 22 | 22 |
TZP15AY42AJ2N | Thermal Zone | 15.2–16 | 8.1 | 18,700–19,300 Btu/h | 56 | 56 |
WLP15AY42AJ2N | Whirlpool | 15.2–16 | 7.8–8.1 | 18,800–19,700 Btu/h | 16 | 17 |
WP15AY42AJ2N | WeatherKing, Rheem +2 more | 15.2–16 | 7.8–8.1 | 18,200–21,000 Btu/h | 286 | 328 |
BH714S42P-**A | AC Pro, Blueridge +1 more | 15.2–15.5 | 7.8–8 | 19,300–20,800 Btu/h | 0 | 124 |
HSA1442S1-**A | Century, Comfort-Aire | 15.2–15.5 | 7.8–8 | 19,300–20,600 Btu/h | 0 | 44 |
(C,H,T)5H6S42*K*AAA* | Kenmore | 15.2–15.5 | 7.8 | 19,000–19,900 Btu/h | 0 | 4 |
235SAN042**AA* | Bryant | 15.2–15.5 | 7.8 | 19,000–19,900 Btu/h | 0 | 7 |
246SAN042**AA* | Bryant | 15.2–15.5 | 7.8 | 19,000–19,900 Btu/h | 0 | 7 |
27SCA542A**30* | Carrier | 15.2–15.5 | 7.8 | 19,000–19,900 Btu/h | 0 | 5 |
27SPA642A**30* | Carrier | 15.2–15.5 | 7.8 | 19,000–19,900 Btu/h | 0 | 5 |
B5H6S42*K*AAA* | Airquest, Arcoaire +6 more | 15.2–15.5 | 7.8 | 19,000–19,900 Btu/h | 0 | 32 |
C5H6S42*K*AAA* | Comfortmaker, Day & Night +1 more | 15.2–15.5 | 7.8 | 19,000–19,900 Btu/h | 0 | 12 |
GH5SAN542**AA* | Bryant, Carrier | 15.2–15.5 | 7.8 | 19,000–19,900 Btu/h | 0 | 12 |
H5H6S42*K*AAA* | Airquest, Arcoaire +1 more | 15.2–15.5 | 7.8 | 19,000–19,900 Btu/h | 0 | 12 |
N5H5S42*K*AAA* | Airquest, Arcoaire +9 more | 15.2–15.5 | 7.8 | 19,000–19,900 Btu/h | 0 | 43 |
PH5SAN542**AA* | Bryant, Payne +2 more | 15.2–15.5 | 7.8 | 19,000–19,900 Btu/h | 0 | 18 |
PH5SAN542**AB* | Weathermaker | 15.2–15.5 | 7.8 | 19,000–19,900 Btu/h | 0 | 3 |
R5H5S42*K*AAA* | Airquest, Arcoaire +9 more | 15.2–15.5 | 7.8 | 19,000–19,900 Btu/h | 0 | 43 |
T5H6S42*K*AAA* | Tempstar | 15.2–15.5 | 7.8 | 19,000–19,900 Btu/h | 0 | 4 |
W5H5S42*K*AAA* | Ecotemp, Grandaire | 15.2–15.5 | 7.8 | 19,000–19,900 Btu/h | 0 | 6 |
DRHP14B42AJ2AN | DuraSTAR | 15.2 | 7.8 | 19,400 Btu/h | 0 | 7 |
FOP1442TJAYNA | Fujitsu | 15.2 | 7.8 | — | 0 | 4 |
FRP14AY42AJ2N | Friedrich | 15.2 | 7.8 | 19,900 Btu/h | 0 | 11 |
FWP14AY42AJ2N | Friedrich | 15.2 | 7.8 | — | 0 | 8 |
J5HP5042A1000AA | Oxbox | 15.2 | 7.8 | 20,200 Btu/h | 0 | 1 |
J5HP5048A1000AA | Oxbox | 15.2 | 7.8 | 21,400–21,600 Btu/h | 0 | 2 |
KOVH-42BAM152L | Kaden | 15.2 | 7.8 | 20,200 Btu/h | 0 | 4 |
MOVA-42HN10-M152L | Midea | 15.2 | 7.8 | 20,200 Btu/h | 0 | 5 |
MOVC-42HN10-M152L | Midea | 15.2 | 7.8 | 20,200 Btu/h | 0 | 4 |
RP14AY42AJ2N | Rheem, Ruud | 15.2 | 7.8 | 19,900 Btu/h | 0 | 12 |
SP14AY42AJ2N | Russell, Sure | 15.2 | 7.8 | 19,900 Btu/h | 0 | 12 |
SPHP-M-1042BB | AC Pro | 15.2 | 7.8 | 20,200 Btu/h | 0 | 2 |
WLP14AY42AJ2N | Whirlpool | 15.2 | 7.8 | 19,400 Btu/h | 0 | 2 |
WP14AY42AJ2N | WeatherKing, Rheem +2 more | 15.2 | 7.8 | 19,900 Btu/h | 0 | 28 |
Same size, other refrigerants: R-410A (39). Nearby sizes: 2.5-ton · 3-ton · 4-ton · 4.5-ton.
Size class is based on the median rated cooling capacity of each unit's certified pairings. Ranges show the spread across pairings, because the indoor unit changes the rating. A load calculation by your installer decides the right size.
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.