Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

DRHP15B42AJ2AN: R-454B heat pump

Sold as DuraSTAR. R-454B Ducted split system, 3.5-ton class, in 50 ENERGY STAR certified pairings with 3 indoor unit models.

Refrigerant
R-454B (GWP 470)
Rated cooling
40,000 Btu/h
SEER2 range
15.2–16
HSPF2 range
7.8–8.1
Heat at 5°F
18,700–19,300 Btu/h
Cold-climate pairings
49 of 50
Compressor
Two-stage
First certified
2024-10-03

This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: DRAC. ENERGY STAR partner: Ferguson Enterprises.

Certified indoor matches

Top 30 of 50 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
DRBEF4821STANMC
DR80UHAW07014171611.78.119,300 Btu/hYes216687097
DRBEF4821STANMC
DR80UHAW1001521U1611.78.118,800 Btu/hYes216687093
DRBEF4824STANMC
DR80UHAW12525241611.78.118,800 Btu/hYes216687109
DRBEF4824STANMC
DR80UHAW1001521U1611.78.118,800 Btu/hYes216687100
DRBEF4821STANMC
DR95M4AW100152115.211.78.119,100 Btu/hYes216686804
DRBEF4824STANMC
DR95UHAW100152115.211.78.119,000 Btu/hYes216686805
DRBEF4824STANMC
DR95M4AW100152115.211.78.119,100 Btu/hYes216686807
DRBEF4824STANMC
DR95M4AW070152115.211.78.119,100 Btu/hYes216686806
DRBEF4824STANMC
DR95M4AW115152415.211.78.118,800 Btu/hYes216686808
DRBEF4821STANMC
DR95UHAW100152115.211.78.119,000 Btu/hYes216686811
DRBEF4821STANMC
DR80UHAW075152115.211.78.118,900 Btu/hYes216686813
DRBEF4821STANMC
DR95M4AW070152115.211.78.119,100 Btu/hYes216686812
DRBEF4821STANMC
DR95M4AW085152115.211.78.119,200 Btu/hYes216686810
DRBEF4824STANMC
DR95M4AW085152115.211.78.119,200 Btu/hYes216686809
DRBEF4824STANMC
DR80UHAW150152415.211.78.118,800 Btu/hYes216686814
DRBEF4824STANMC
DR80DZAW125152415.211.78.118,700 Btu/hYes216686818
DRBEF4824STANMC
DR80UHAW1001521S15.211.78.118,800 Btu/hYes216686816
DRBEF4824STANMC
DR80DZAW075152115.211.78.118,800 Btu/hYes216686819
DRBEF4821STANMC
DR80DZAW075241715.211.78.119,300 Btu/hYes216686820
DRBEF4821STANMC
DR80UHAW075141715.211.78.118,800 Btu/hYes216686815
DRBEF4824STANMC
DR80UHAW1001521N15.211.78.118,800 Btu/hYes216686824
DRBEF4824STANMC
DR80UHAW075152115.211.78.118,900 Btu/hYes216686830
DRBEF4824STANMC
DR80DZAW125252415.211.78.118,700 Btu/hYes216686827
DRBEF4824STANMC
DR80UHAW075252115.211.78.118,900 Btu/hYes216686821
DRBEF4821STANMC
DR80UHAW100252115.211.78.118,800 Btu/hYes216686828
DRBEF4824STANMC
DR80DZAW100252115.211.78.118,700 Btu/hYes216686823
DRBEF4824STANMC
DR80DZAW100152115.211.78.118,700 Btu/hYes216686822
DRBEF4824STANMC
DR80UHAW150252415.211.78.118,800 Btu/hYes216686826
DRBEF4821STANMC
DR80DZAW100252115.211.78.118,700 Btu/hYes216686835
DRBEF4821STANMC
DR80DZAW075141715.211.78.119,300 Btu/hYes216686833
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-454B 3.5-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
BOVA-60MTB-M19EBosch15.2–198.5–1040,500–55,000 Btu/h25
BOVB-60MTB-M19EBosch15.2–198.5–1040,500–55,000 Btu/h25
MOVA-60HDN10-M20GMidea15.2–198.5–1040,500–55,000 Btu/h25
MOVC-60HDN10-M20GMidea15.2–198.5–1040,500–55,000 Btu/h25
RD18AY48AJVCFriedrich, Russell +3 more16–198.1–1030,800–38,000 Btu/h674
ACIQ-42-HPDACiQ, 1HVAC15.7–16.78.8–9.542,000–46,000 Btu/h3
BOVA-60RTB-M20SBosch16–18.58.5–9.531,000–38,500 Btu/h25
BOVB-60RTB-M20SBosch16–18.58.5–9.531,000–38,500 Btu/h25

All 94 R-454B 3.5-ton units

More DuraSTAR R-454B units

Next step