Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

5A6H6048A1: R-454B heat pump

Sold as American Standard. R-454B Ducted split system, 3.5-ton class, in 127 ENERGY STAR certified pairings with 28 indoor unit models.

Refrigerant
R-454B (GWP 470)
Rated cooling
44,000 Btu/h
SEER2 range
15.2–16
HSPF2 range
7.8–8.5
Heat at 5°F
21,800–22,600 Btu/h
Cold-climate pairings
0 of 127
Compressor
Single stage
First certified
2026-03-26

This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: Silver 16. ENERGY STAR partner: Trane and American Standard Heating and Air Conditioning.

Certified indoor matches

Top 30 of 127 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
5TEMCD06AV41+TDR+TSTAT
—16128.522,000 Btu/hNo218109017
5TXCD010AS3+TSTAT
S8V2D120M5PDB16128.122,000 Btu/hNo218109199
5TXCD010AS3+TSTAT
S8V2D120M5PCB16128.122,000 Btu/hNo218109197
5TXCD010AS3+TSTAT+P0V0D000M50SD
—16128.121,800 Btu/hNo218109187
5TXCD010AS3+TSTAT
S8X2D120M5PTC16128.122,200 Btu/hNo218109169
5TXCD010AS3+TSTAT
S8X2D120M5PSC16128.122,200 Btu/hNo218109167
5TXCD010AS3+TSTAT
S8X1D120M5PTC16128.122,200 Btu/hNo218109159
5TXCD010AS3+TSTAT
S8X1D120M5PSC16128.122,200 Btu/hNo218109157
5TXCD008AS3+TSTAT+P0V0D000M50SD
—16128.122,000 Btu/hNo218109121
5TXCC009AS3+TSTAT+P0V0C000M50SD
—16128.121,800 Btu/hNo218109115
5TXCC009AS3+TSTAT
S9V2C080U5VSB16128.122,200 Btu/hNo218109093
5TEMCD07AV51+TDR+TSTAT
—16128.121,800 Btu/hNo218109019
5TEM6D07AV51+TDR+TSTAT
—16128.121,800 Btu/hNo218109013
5TEM6D06AV41+TDR+TSTAT
—16128.121,800 Btu/hNo218109011
5PX*D010AS3+TSTAT
S8V2D120M5PCB16128.122,000 Btu/hNo218108983
5PX*D010AS3+TSTAT
S8X2D120M5PTC16128.122,200 Btu/hNo218108979
5PX*D010AS3+TSTAT
S8X2D120M5PSC16128.122,200 Btu/hNo218108977
5PX*D010AS3+TSTAT
S8X1D120M5PTC16128.122,200 Btu/hNo218108967
5PX*D010AS3+TSTAT
S8X1D120M5PSC16128.122,200 Btu/hNo218108965
5PX*D010AS3+TSTAT
S9X1D120U5PSB16128.122,000 Btu/hNo218108957
5PX*D010AS3+TSTAT
S9X2D120U5PSB16128.122,000 Btu/hNo218108955
5PX*D010AS3+TSTAT+P0V0C000M50SD
—16128.121,800 Btu/hNo218108949
5PX*D010AS3+TSTAT+P0V0D000M50SD
—16128.121,800 Btu/hNo218108947
5PX*D010AS3+TSTAT
S8V2D120M5PDB16128.122,000 Btu/hNo218108943
5PX*D008AS3+TSTAT+P0V0D000M50SD
—16128.122,000 Btu/hNo218108927
5PX*C009AS3+TSTAT+P0V0C000M50SD
—16128.121,800 Btu/hNo218108871
5PX*C009AS3+TSTAT
S9V2C080U5VSB16128.122,200 Btu/hNo218108867
5PX*DD10AS3+TSTAT+P0V0D000M50SD
—16128.122,000 Btu/hNo218395759
5TEMCD07BV51+TDR+TSTAT
—16128.122,200 Btu/hNo218788174
5TXCD008AS3+TSTAT+P0V0C000M50SD
—1612822,000 Btu/hNo218109119
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-454B 3.5-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
BOVA-60MTB-M19EBosch15.2–198.5–1040,500–55,000 Btu/h25
BOVB-60MTB-M19EBosch15.2–198.5–1040,500–55,000 Btu/h25
MOVA-60HDN10-M20GMidea15.2–198.5–1040,500–55,000 Btu/h25
MOVC-60HDN10-M20GMidea15.2–198.5–1040,500–55,000 Btu/h25
RD18AY48AJVCFriedrich, Russell +3 more16–198.1–1030,800–38,000 Btu/h674
ACIQ-42-HPDACiQ, 1HVAC15.7–16.78.8–9.542,000–46,000 Btu/h3
BOVA-60RTB-M20SBosch16–18.58.5–9.531,000–38,500 Btu/h25
BOVB-60RTB-M20SBosch16–18.58.5–9.531,000–38,500 Btu/h25

All 94 R-454B 3.5-ton units

More American Standard R-454B units

Next step