Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

HH860E2S12: R-454B heat pump

Sold as Coleman, Luxaire, York, Champion +1 more. R-454B Ducted split system, 3.5-ton class, in 2,092 ENERGY STAR certified pairings with 47 indoor unit models.

Refrigerant
R-454B (GWP 470)
Rated cooling
44,500 Btu/h
SEER2 range
15.2–18
HSPF2 range
8.1–8.5
Heat at 5°F
33,600–40,000 Btu/h
Cold-climate pairings
15 of 2,092
Compressor
Two-stage
First certified
2026-07-17

This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: LX SERIES. ENERGY STAR partner: Johnson Controls, Inc..

Certified indoor matches

Top 30 of 2,092 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
JHC60C5CH2SS1
—18118.138,000 Btu/hNo218598236
JSE60D5CJ2SS1
—18118.139,000 Btu/hNo218642630
JHC60D5CJ2SS1
—18118.139,000 Btu/hNo218642625
JSC60D5CJ2SS1
—18118.139,000 Btu/hNo218642618
JHC60C5CH2SS1
—18118.138,000 Btu/hNo218598228
JSE60D5CJ2SS1
—18118.139,000 Btu/hNo218642626
JHC60D5CJ2SS1
—18118.139,000 Btu/hNo218642619
JSC60D5CJ2SS1
—18118.139,000 Btu/hNo218642613
JHC60C5CH2SS1
—18118.138,000 Btu/hNo218598239
JSE60D5CJ2SS1
—18118.139,000 Btu/hNo218642629
JHC60D5CJ2SS1
—18118.139,000 Btu/hNo218642623
JSC60D5CJ2SS1
—18118.139,000 Btu/hNo218642616
JHC60C5CH2SS1
—18118.138,000 Btu/hNo218598242
JSE60D5CJ2SS1
—18118.139,000 Btu/hNo218642627
JHC60D5CJ2SS1
—18118.139,000 Btu/hNo218642621
JSC60D5CJ2SS1
—18118.139,000 Btu/hNo218642615
JHC60C5CH2SS1
—18118.138,000 Btu/hNo218598222
JSE60D5CJ2SS1
—18118.139,000 Btu/hNo218641571
JHC60D5CJ2SS1
—18118.139,000 Btu/hNo218641570
JSC60D5CJ2SS1
—18118.139,000 Btu/hNo218641569
JHC48C5CG2SS1
—17.5128.534,000 Btu/hYes218598240
CTF60D5CGS2+JME18D2SN2
—17.5128.536,000 Btu/hYes218642148
JSC48C5CG2SS1
—17.5128.534,000 Btu/hYes218641941
JHC48C5CG2SS1
—17.5128.534,000 Btu/hYes218598231
CTF60D5CGS2+JME18D2SN2
—17.5128.536,000 Btu/hYes218642143
JSC48C5CG2SS1
—17.5128.534,000 Btu/hYes218641938
JHC48C5CG2SS1
—17.5128.534,000 Btu/hYes218598243
CTF60D5CGS2+JME18D2SN2
—17.5128.536,000 Btu/hYes218642146
JSC48C5CG2SS1
—17.5128.534,000 Btu/hYes218641940
JHC48C5CG2SS1
—17.5128.534,000 Btu/hYes218598229
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-454B 3.5-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
BOVA-60MTB-M19EBosch15.2–198.5–1040,500–55,000 Btu/h25
BOVB-60MTB-M19EBosch15.2–198.5–1040,500–55,000 Btu/h25
MOVA-60HDN10-M20GMidea15.2–198.5–1040,500–55,000 Btu/h25
MOVC-60HDN10-M20GMidea15.2–198.5–1040,500–55,000 Btu/h25
RD18AY48AJVCFriedrich, Russell +3 more16–198.1–1030,800–38,000 Btu/h674
ACIQ-42-HPDACiQ, 1HVAC15.7–16.78.8–9.542,000–46,000 Btu/h3
BOVA-60RTB-M20SBosch16–18.58.5–9.531,000–38,500 Btu/h25
BOVB-60RTB-M20SBosch16–18.58.5–9.531,000–38,500 Btu/h25

All 94 R-454B 3.5-ton units

More Coleman R-454B units

Next step

Some links are affiliate links; we may earn a commission at no cost to you. Disclosure.