Kenmore · ENERGY STAR data November 12, 2026
Kenmore heat pump refrigerants: R-454B / R-410A
Kenmore has 161 ENERGY STAR certified outdoor unit models (116 R-454B, 45 R-410A) in 46,231 certified systems.
R-454B 116 (72%)R-410A 45 (28%)
- Main refrigerant
- R-454B
- Outdoor models
- 161
- Ducted / mini / packaged
- 86 / 67 / 8
- Certified systems
- 46,231
Some of these outdoor units are also listed under Day & Night, Arcoaire, Keeprite, Tempstar, Airquest, Comfortmaker.
Which refrigerant a Kenmore system uses depends on the exact outdoor model, not the brand. Check the model below or in the lookup, and make sure the indoor coil or air handler on your quote is certified with it.
Kenmore R-454B outdoor units
| Outdoor unit | Type | Size | SEER2 | HSPF2 | Heat at 5°F | Certified pairings |
|---|---|---|---|---|---|---|
D5CPRAH06AAK | Mini/multi-split | 6,000 Btu | 33.1 | 15.6 | 13,500 Btu/h | 11 |
D5CPRAH18AA | Mini/multi-split | 18,000 Btu | 24.5 | 15.2 | 22,600 Btu/h | 11 |
D5CSHAH06AAK | Mini/multi-split | 6,000 Btu | 21.5–25.7 | 12–14.8 | 7,700–8,100 Btu/h | 35 |
D5CPRAH09AAK | Mini/multi-split | 9,000 Btu | 31.5 | 14.6 | 13,500 Btu/h | 11 |
D5CSRAH09AAK | Mini/multi-split | 9,000 Btu | 19.6–26 | 11–13.9 | 8,000–8,600 Btu/h | 66 |
D5CSHAH09AAK | Mini/multi-split | 9,000 Btu | 20.6–27.5 | 10.9–13.8 | 10,600–11,900 Btu/h | 72 |
D5CSRAH18AAK | Mini/multi-split | 18,000 Btu | 18.5–23.9 | 9.8–13.5 | 12,800–14,200 Btu/h | 89 |
D5CSHAH24AAK | Mini/multi-split | 24,000 Btu | 18.8–21.2 | 10–13.5 | 23,600–24,200 Btu/h | 61 |
D5CPRAH12AAK | Mini/multi-split | 12,000 Btu | 28 | 12.7 | 13,500 Btu/h | 11 |
D5CSHAH18AAK | Mini/multi-split | 18,000 Btu | 18–21.5 | 10.1–12.4 | 17,000–18,000 Btu/h | 97 |
D5CSRAH24AAK | Mini/multi-split | 24,000 Btu | 19–23.1 | 9–11.7 | 18,000–19,600 Btu/h | 56 |
D5CSHAH12AAK | Mini/multi-split | 12,000 Btu | 20–25.5 | 10.2–11.6 | 11,300–12,000 Btu/h | 72 |
D5CMHAH48FAK | Mini/multi-split | 48,000 Btu | 20.5–23 | 11–11.3 | 47,000–48,000 Btu/h | 36 |
D5CLHAH36AAK | Mini/multi-split | 36,000 Btu | 17.3–21.3 | 9.5–11.1 | 37,000–39,500 Btu/h | 49 |
D5CSRAH12AAK | Mini/multi-split | 12,000 Btu | 19–25.5 | 10.1–11 | 8,400–8,900 Btu/h | 66 |
D5CLHAH48AAK | Mini/multi-split | 48,000 Btu | 16.8–18.7 | 10.1–11 | 46,000–47,500 Btu/h | 49 |
D5CUHAH18AAK | Ducted | 1.5-ton | 15.5–19.3 | 9.5–10.8 | 18,000–19,600 Btu/h | 77 |
D5CUHAH30AAK | Ducted | 2.5-ton | 15.3–17.5 | 9.3–10.8 | 30,400–33,200 Btu/h | 82 |
D5CMHAH30EAK | Mini/multi-split | 30,000 Btu | 19.5–24 | 10.5–10.7 | 36,000 Btu/h | 36 |
D5CMHAH36EAK | Mini/multi-split | 36,000 Btu | 19.5–23.1 | 10.5–10.7 | 36,000–38,000 Btu/h | 36 |
D5CMHAH55FAK | Mini/multi-split | 48,000 Btu | 20.2–22.3 | 10.5–10.7 | 47,000–48,000 Btu/h | 36 |
D5CLHAH58AAK | Mini/multi-split | 48,000 Btu | 15.4–18.1 | 9.2–10.7 | 53,000–54,000 Btu/h | 37 |
D5CMRAH48FAK | Mini/multi-split | 48,000 Btu | 20.5–24 | 10.4–10.6 | 36,000–38,000 Btu/h | 33 |
D5CMHAH18CAK | Mini/multi-split | 18,000 Btu | 20–25 | 10–10.5 | 18,000–19,000 Btu/h | 36 |
B5H3V24*K*AAA* | Ducted | 2-ton | 18–23 | 8.5–10.5 | 19,100–23,000 Btu/h | 3,771 |
All 116 Kenmore R-454B outdoor units
Kenmore R-410A outdoor units
| Outdoor unit | Type | Size | SEER2 | HSPF2 | Heat at 5°F | Certified pairings |
|---|---|---|---|---|---|---|
DLCPRBH09AAK | Mini/multi-split | 9,000 Btu | 25.5–27 | 11.5–17.5 | 12,000–13,700 Btu/h | 29 |
DLCPRBH18AAK | Mini/multi-split | 18,000 Btu | 26.3 | 11–15.5 | 24,000 Btu/h | 16 |
DLCSRBH06AAK | Mini/multi-split | 6,000 Btu | 22–26.5 | 10.8–13.6 | 7,100–8,000 Btu/h | 48 |
DLCSRBH09AAK | Mini/multi-split | 9,000 Btu | 20.2–28.1 | 10–12.4 | 10,000–11,000 Btu/h | 99 |
DLCPRBH12AAK | Mini/multi-split | 12,000 Btu | 24–25.3 | 10.5–11.7 | 12,000–13,700 Btu/h | 30 |
DLCSRBH24AAK | Mini/multi-split | 24,000 Btu | 16.6–22.3 | 8.5–11.5 | 21,200–27,000 Btu/h | 169 |
DLCSRBH18AAK | Mini/multi-split | 18,000 Btu | 17.6–22 | 9.5–11.3 | 16,000–18,000 Btu/h | 201 |
DLCSRBH12AAK | Mini/multi-split | 12,000 Btu | 19.5–25.5 | 9.5–10.7 | 11,000–12,100 Btu/h | 110 |
DLCSRBH12AAJ | Mini/multi-split | 12,000 Btu | 22.7–23.5 | 10–10.4 | 6,700–6,800 Btu/h | 35 |
DLCMRBH18BAK | Mini/multi-split | 18,000 Btu | 19–21 | 9.8–10.2 | 12,600–13,300 Btu/h | 42 |
DLCMHBH48EAK | Mini/multi-split | 48,000 Btu | 20.9–21.2 | 9–10 | 42,500–45,000 Btu/h | 36 |
DLCMHBH36DAK | Mini/multi-split | 36,000 Btu | 19–20 | 9.7–10 | 33,000–36,000 Btu/h | 36 |
DLCLRCH48AAK | Mini/multi-split | 48,000 Btu | 15.2–18.9 | 9.7–10 | 35,000–35,600 Btu/h | 24 |
DLCURAH24ABK | Ducted | 2-ton | 16.1–18 | 9.5–10 | 20,000–23,200 Btu/h | 60 |
DLCURAH36ABK | Ducted | 3-ton | 15.2–16 | 8.6–10 | 31,600–34,400 Btu/h | 48 |
DLCURAH24AAK | Ducted | 2-ton | 15.7–17 | 9.2–9.8 | 18,500–20,800 Btu/h | 35 |
DLCMHBH24CAK | Mini/multi-split | 24,000 Btu | 21.3–22.3 | 9.6–9.7 | 17,000–18,000 Btu/h | 38 |
DLCURAH30ABK | Ducted | 2.5-ton | 15.2–16.2 | 8.5–9.7 | 22,600–27,000 Btu/h | 36 |
DLCURAH48ABK | Ducted | 4-ton | 15.6–15.9 | 9.4–9.6 | 46,000–46,500 Btu/h | 34 |
DLCMHBH30DAK | Mini/multi-split | 30,000 Btu | 20–22.4 | 9.2–9.5 | 18,000–23,000 Btu/h | 36 |
DLCMRBH48EAK | Mini/multi-split | 48,000 Btu | 21.1 | 9.5 | 33,000 Btu/h | 12 |
DLCURAH18ABK | Ducted | 1.5-ton | 16.1–18 | 9.3–9.5 | 15,000–16,500 Btu/h | 35 |
DLCERBH09AAK | Mini/multi-split | 9,000 Btu | 21.7 | 9.4 | 7,000 Btu/h | 16 |
DLCURAH60ABK | Ducted | 4.5-ton | 15.3 | 9.4 | 48,500 Btu/h | 22 |
DLCMRBH36DAK | Mini/multi-split | 36,000 Btu | 20 | 9.2 | 24,000 Btu/h | 12 |
All 45 Kenmore R-410A outdoor units
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.