Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

RP19AY24AJVC: R-454B heat pump

Sold as Rheem. R-454B Ducted split system, 2-ton class, in 32 ENERGY STAR certified pairings with 2 indoor unit models.

Refrigerant
R-454B (GWP 470)
Rated cooling
22,800 Btu/h
SEER2 range
20–21
HSPF2 range
8.5–10
Heat at 5°F
17,400–19,500 Btu/h
Cold-climate pairings
27 of 32
Compressor
Continuously variable
First certified
2025-04-09

This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: PRESTIGE SERIES, Prestige. ENERGY STAR partner: Rheem Sales Company, Inc..

Certified indoor matches

Top 30 of 32 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
RCFY2421HEAAM
R921V0403A17M421131018,500 Btu/hYes216050993
RCFY2421HEAAM
R951V0403A17M421131018,500 Btu/hYes216050996
RCFY2421HEAAM
R951V0603A17UH21131018,600 Btu/hYes216050995
RCFY2421HEAAM
R951V0603A17M421131018,600 Btu/hYes216051002
RCFY2421HEAAM
R921V0603A17M421131018,600 Btu/hYes216051004
RCFY2421HEAAM
R951V0403A17UH21131018,700 Btu/hYes216051006
RCFY2421HEAAM
R962V0603A17M421131018,600 Btu/hYes216051008
RCFY2421HEAAM
R97MV0855A21DH21131018,400 Btu/hYes216051010
RCFY2421HEAAM
R98MV1005A21UP21131018,500 Btu/hYes216051016
RCFY2421HEAAM
R98MV0855A21UP21131018,400 Btu/hYes216051020
RCFY2421HEAAM
R98MV0603A17UP21131018,500 Btu/hYes216051024
RCFY2421HEAAM
R97MV0703A17DH21131018,500 Btu/hYes216051035
RCFY2421HEAAM
R962V0403A17M421131018,500 Btu/hYes216051037
RCFY2421HEAAM
R97MV0603A17DH21131018,500 Btu/hYes216051038
RCFY2421HEAAM
R801V0754A17UH21131018,400 Btu/hYes216051046
RCFY2421HEAAM
R802V0754A17UH21131018,400 Btu/hYes216051053
RCFY2421HEAAM
R801V0704A17UH21131018,500 Btu/hYes216051056
RCFY2421HEAAM
R972V0603A17UPS21138.517,500 Btu/hNo218728655
RCFY2421HEAAM
R972V0403A17UPS21138.517,400 Btu/hNo218814084
RCFY2421HEAAM
R921V0703A17M420121018,600 Btu/hYes216050987
RCFY2421HEAAM
R951V0703A17M420121018,600 Btu/hYes216050992
RCFY2421HEAAM
R962V0703A17M420121018,600 Btu/hYes216051023
RCFY2421HEAAM
R97MV1005A21DH20121018,400 Btu/hYes216051027
RCFY2421HEAAM
R98MV0703A17UP20121018,500 Btu/hYes216051030
RCFY2421HEAAM
R801V0504A17UHS20121018,500 Btu/hYes216051042
RCFY2421HEAAM
R801V0504A17UHN20121018,500 Btu/hYes216051043
RCFY2421HEAAM
R802V0504A17UH20121018,500 Btu/hYes216051057
RCFY2421HEAAM
R801V0504A17UHU20121018,600 Btu/hYes216051058
RHMVY3621MEACA
—20139.519,500 Btu/hYes215739589
RCFY2421HEAAM
R802V1005A21UH20138.518,400 Btu/hNo216696545
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-454B 2-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
5A6H7024A1American Standard15.2–17.18.1–1116,700–17,700 Btu/h245
5TWR7024A1Trane15.2–17.18.1–1116,700–17,700 Btu/h245
5TWX7024A1Trane15.2–188–1116,700–17,600 Btu/h241
27VNA324A*030*Carrier18–238.5–10.519,100–23,000 Btu/h430
293VAN024**AA*Bryant18–238.5–10.519,100–23,000 Btu/h430
37MUHAQ24AA3Bryant, Carrier +3 more16–18.79–10.519,100–21,600 Btu/h41
A-VXP24SA-1Century, Comfort Aire +1 more16–18.39.5–10.519,600–21,600 Btu/h12
ACIQ-24-HPDACiQ, 1HVAC16–18.68.9–10.519,600–21,600 Btu/h19

All 283 R-454B 2-ton units

More Rheem R-454B units

Next step