Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

A5HP5024A1: R-454B heat pump

Sold as Ameristar, RunTru. R-454B Ducted split system, 2-ton class, in 72 ENERGY STAR certified pairings with 11 indoor unit models.

Refrigerant
R-454B (GWP 470)
Rated cooling
23,300 Btu/h
SEER2 range
15.2–16
HSPF2 range
7.8–8.1
Heat at 5°F
10,600–11,800 Btu/h
Cold-climate pairings
0 of 72
Compressor
Single stage
First certified
2025-04-09

This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: A5HP5. ENERGY STAR partner: Trane and American Standard Heating and Air Conditioning.

Certified indoor matches

Top 30 of 72 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
5TXCB006AS3+TSTAT
A952V040BU3SA16128.111,200 Btu/hNo214296243
5TXCB006AS3+TSTAT
A952V040BU3SB16128.111,200 Btu/hNo214296245
5TXCB006AS3+TSTAT
A952V060BU4SA16128.111,200 Btu/hNo214296247
5TXCB006AS3+TSTAT
A952V060BU4SB16128.111,200 Btu/hNo214296249
A5AHV004A1D3+TDR+TSTAT
—16128.111,600 Btu/hNo214296267
A5AHV005A1D3+TDR+TSTAT
—16128.111,600 Btu/hNo215611073
5TXCB006AS3+TSTAT
A952V040BU3SA16128.111,200 Btu/hNo214296242
5TXCB006AS3+TSTAT
A952V040BU3SB16128.111,200 Btu/hNo214296244
5TXCB006AS3+TSTAT
A952V060BU4SA16128.111,200 Btu/hNo214296246
5TXCB006AS3+TSTAT
A952V060BU4SB16128.111,200 Btu/hNo214296248
A5AHV004A1D3+TDR+TSTAT
—16128.111,600 Btu/hNo214296266
A5AHV005A1D3+TDR+TSTAT
—16128.111,600 Btu/hNo215611072
5PX*BD06AS3+TSTAT
A952V060BD3SB1612811,400 Btu/hNo215574549
5PX*BD06AS3+TSTAT
A951X040BD3SA1612811,500 Btu/hNo215574553
A5AHC004A1B3+TDR+TSTAT
—1612811,400 Btu/hNo218154630
5PX*BD06AS3+TSTAT
A952V060BD3SB1612811,400 Btu/hNo215574548
5PX*BD06AS3+TSTAT
A951X040BD3SA1612811,500 Btu/hNo215574552
A5AHC004A1B3+TDR+TSTAT
—1612811,400 Btu/hNo218154629
5TXCB006AS3+TSTAT
L8V1A040U3VSB16127.811,100 Btu/hNo214296251
5TXCB006AS3+TSTAT
L8V1A060U3VSB16127.811,100 Btu/hNo214296253
5TXCB006AS3+TSTAT
L8V1B080U4VSB16127.811,400 Btu/hNo214296255
5TXCB006AS3+TSTAT
L8V1A040U3VSB16127.811,100 Btu/hNo214296250
5TXCB006AS3+TSTAT
L8V1A060U3VSB16127.811,100 Btu/hNo214296252
5TXCB006AS3+TSTAT
L8V1B080U4VSB16127.811,400 Btu/hNo214296254
5TXCB004AS3+TSTAT
A951X060BU4SA15.2128.111,400 Btu/hNo214296201
5TXCB004AS3+TSTAT
A951X080BU4SA15.2128.111,200 Btu/hNo214296203
A5AHV003A1B3+TDR+TSTAT
—15.2128.111,800 Btu/hNo214296265
A5AHC003A1B3+TDR+TSTAT
—15.2128.111,400 Btu/hNo215611067
A5AHC004A1D3+TDR+TSTAT
—15.2128.111,100 Btu/hNo215611069
A5AHV002A1B3+TDR+TSTAT
—15.2128.111,300 Btu/hNo215611071
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-454B 2-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
5A6H7024A1American Standard15.2–17.18.1–1116,700–17,700 Btu/h245
5TWR7024A1Trane15.2–17.18.1–1116,700–17,700 Btu/h245
5TWX7024A1Trane15.2–188–1116,700–17,600 Btu/h241
27VNA324A*030*Carrier18–238.5–10.519,100–23,000 Btu/h430
293VAN024**AA*Bryant18–238.5–10.519,100–23,000 Btu/h430
37MUHAQ24AA3Bryant, Carrier +3 more16–18.79–10.519,100–21,600 Btu/h41
A-VXP24SA-1Century, Comfort Aire +1 more16–18.39.5–10.519,600–21,600 Btu/h12
ACIQ-24-HPDACiQ, 1HVAC16–18.68.9–10.519,600–21,600 Btu/h19

All 283 R-454B 2-ton units

More Ameristar R-454B units

Next step