Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

5TWX5024A1: R-454B heat pump

Sold as Trane. R-454B Ducted split system, 2-ton class, in 75 ENERGY STAR certified pairings with 19 indoor unit models.

Refrigerant
R-454B (GWP 470)
Rated cooling
23,800 Btu/h
SEER2 range
15.2–16.5
HSPF2 range
7.8–8.1
Heat at 5°F
10,600–11,700 Btu/h
Cold-climate pairings
0 of 75
Compressor
Single stage
First certified
2025-04-09

This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: 15 Single-Stage Heat Pump with WeatherGuard Top. ENERGY STAR partner: Trane and American Standard Heating and Air Conditioning.

Certified indoor matches

Top 30 of 75 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
5TEMCD06AV41+TDR+TSTAT
—16.512811,000 Btu/hNo215863968
5TEMCD07AV51+TDR+TSTAT
—16.5127.811,000 Btu/hNo215863969
5TEM6D04AV31+TDR+TSTAT
—16128.111,600 Btu/hNo214181742
5TEM6D06AV41+TDR+TSTAT
—16128.111,500 Btu/hNo214181744
5TXCB006AS3+TSTAT
S9X1B060U4PSB16128.111,400 Btu/hNo214181988
5TXCB006AS3+TSTAT
S9X2B060U4PSB16128.111,400 Btu/hNo214181990
5TXCC007AS3+TSTAT
*UHMC100CCV416128.111,100 Btu/hNo214182007
5TEM6D05AV41+TDR+TSTAT
—16128.111,600 Btu/hNo215610970
5TEMCD04AV31+TDR+TSTAT
—16128.111,100 Btu/hNo215863966
5TEMCD05AV41+TDR+TSTAT
—16128.111,100 Btu/hNo215863967
5TEM4B04AC31+TDR+TSTAT
—1612811,400 Btu/hNo218154619
5TXCB006AS3+TSTAT
S8V2B080M4PCA16127.811,100 Btu/hNo214181923
5TXCB006AS3+TSTAT
S8V2B080M4PDA16127.811,100 Btu/hNo214181935
5TXCB006AS3+TSTAT
S8X1B060M4PSC16127.811,300 Btu/hNo214181939
5TXCB006AS3+TSTAT
S8X1B060M4PTC16127.811,300 Btu/hNo214181941
5TXCB006AS3+TSTAT
S8X1B080M4PSC16127.811,400 Btu/hNo214181943
5TXCB006AS3+TSTAT
S8X1B080M4PTC16127.811,400 Btu/hNo214181946
5TXCB006AS3+TSTAT
S8X2B060M4PSC16127.811,300 Btu/hNo214181948
5TXCB006AS3+TSTAT
S8X2B060M4PTC16127.811,300 Btu/hNo214181950
5TXCB006AS3+TSTAT
S8X2B080M4PSC16127.811,400 Btu/hNo214181952
5TXCB006AS3+TSTAT
S8X2B080M4PTC16127.811,400 Btu/hNo214181954
5TXCB006AS3+TSTAT
S9V2B060U3VSA16127.811,100 Btu/hNo214181970
5TXCB004AS3+TSTAT
L9X1A050U3VSA1611.77.810,600 Btu/hNo214181915
5TXCB006AS3+TSTAT
S8V2A040M3PCB16127.810,800 Btu/hNo214181999
5TXCB006AS3+TSTAT
S8V2A040M3PDB16127.810,800 Btu/hNo214181995
5TXCB006AS3+TSTAT
*UHMB060CCV316127.811,000 Btu/hNo214181927
5TEM6B03AV21+TDR+TSTAT
—15.5128.111,700 Btu/hNo214181740
5TXCB006AS3+TSTAT
S9V2B080U4VSA15.5128.111,300 Btu/hNo214181980
5TXCB004AS3+TSTAT
S9X1B080U4PSB15.5128.111,200 Btu/hNo214181902
5TXCB004AS3+TSTAT
S9X2B080U4PSB15.5128.111,200 Btu/hNo214181913
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-454B 2-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
5A6H7024A1American Standard15.2–17.18.1–1116,700–17,700 Btu/h245
5TWR7024A1Trane15.2–17.18.1–1116,700–17,700 Btu/h245
5TWX7024A1Trane15.2–188–1116,700–17,600 Btu/h241
27VNA324A*030*Carrier18–238.5–10.519,100–23,000 Btu/h430
293VAN024**AA*Bryant18–238.5–10.519,100–23,000 Btu/h430
37MUHAQ24AA3Bryant, Carrier +3 more16–18.79–10.519,100–21,600 Btu/h41
A-VXP24SA-1Century, Comfort Aire +1 more16–18.39.5–10.519,600–21,600 Btu/h12
ACIQ-24-HPDACiQ, 1HVAC16–18.68.9–10.519,600–21,600 Btu/h19

All 283 R-454B 2-ton units

More Trane R-454B units

Next step

Some links are affiliate links; we may earn a commission at no cost to you. Disclosure.