Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

ML16KP2-024-230A**: R-454B heat pump

Sold as Lennox. R-454B Ducted split system, 2-ton class, in 71 ENERGY STAR certified pairings with 12 indoor unit models.

Refrigerant
R-454B (GWP 470)
Rated cooling
24,000 Btu/h
SEER2 range
16–17.5
HSPF2 range
7.8–8.2
Heat at 5°F
9,900–11,100 Btu/h
Cold-climate pairings
0 of 71
Compressor
Two-stage
First certified
2026-06-09

This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: Merit ML16KP2 SERIES. ENERGY STAR partner: Lennox Industries.

Certified indoor matches

Top 30 of 71 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
CK40DT-30/36B-**+TDR
EL297DF045XV36B*17.5137.810,200 Btu/hNo218457543
CK40DT-24B-**+TDR
EL297DF045XV36B*17138.110,900 Btu/hNo218457587
CBK48MVT-018/024-230-**
—17138.110,800 Btu/hNo218457522
CK40DT-24B-**+TDR
SLP99DF070XV36B*1713810,800 Btu/hNo218457589
CK40DT-24B-**+TDR
EL297DF070XV48B*1712.5811,100 Btu/hNo218457588
CK40DT-24B-**+TDR
ML193DF070XE36B*1712.5811,000 Btu/hNo218457586
CK40DT-24B-**+TDR
SL280DF090V48B*1712.5811,100 Btu/hNo218457583
CK40DT-24B-**+TDR
ML196DF045XE36B*1712.5811,000 Btu/hNo218457580
CK40DT-24B-**+TDR
ML193DF045XE36B*1712.5811,000 Btu/hNo218457579
CK40HT-24B-**+TDR
EL297UH070XV36B*17137.810,300 Btu/hNo218457574
CK40HT-24B-**+TDR
EL297UH045XV36B*17137.810,400 Btu/hNo218457573
CK40HT-24B-**+TDR
SL297UH040NV36B*17137.810,500 Btu/hNo218457570
CK40HT-24B-**+TDR
SL280UH090V48B*17137.810,300 Btu/hNo218457569
CK40HT-24B-**+TDR
ML296UH045XV36B*17137.810,400 Btu/hNo218457568
CK40HT-24B-**+TDR
ML193UH045XE36B*1712.57.810,600 Btu/hNo218457567
CK40HT-24B-**+TDR
ML180UH070E36B*17137.810,300 Btu/hNo218457566
CK40HT-24B-**+TDR
ML180UH045E36A*17137.810,200 Btu/hNo218457565
CK40HT-24B-**+TDR
EL280UH070E36A*17137.810,500 Btu/hNo218457564
CK40HT-24B-**+TDR
EL280UH045E36A*17137.810,200 Btu/hNo218457563
CK40HT-24B-**+TDR
SLP99UH070XV36B*17137.810,400 Btu/hNo218457561
CK40HT-24B-**+TDR
SL297UH060NV36B*17137.810,400 Btu/hNo218457560
CK40HT-24B-**+TDR
SL280UH090V36B*1713.57.810,300 Btu/hNo218457559
CK40HT-24B-**+TDR
ML193UH070XE36B*17137.810,500 Btu/hNo218457556
CK40HT-24B-**+TDR
ML180UH090V48B*17137.810,500 Btu/hNo218457555
CK40HT-24B-**+TDR
ML180UH070XE36B*17137.810,300 Btu/hNo218457554
CK40HT-24B-**+TDR
ML180UH070V36B*1713.57.810,300 Btu/hNo218457553
CK40HT-24B-**+TDR
EL280UH090E36B*17137.810,500 Btu/hNo218457552
CK40DT-30/36C-**+TDR
SLP99DF090XV36C*17137.810,000 Btu/hNo218457547
CK40DT-30/36B-**+TDR
SL280DF070V36A*17137.810,200 Btu/hNo218457546
CK40DT-30/36B-**+TDR
EL297DF070XV48B*1712.57.810,400 Btu/hNo218457545
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-454B 2-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
5A6H7024A1American Standard15.2–17.18.1–1116,700–17,700 Btu/h245
5TWR7024A1Trane15.2–17.18.1–1116,700–17,700 Btu/h245
5TWX7024A1Trane15.2–188–1116,700–17,600 Btu/h241
27VNA324A*030*Carrier18–238.5–10.519,100–23,000 Btu/h430
293VAN024**AA*Bryant18–238.5–10.519,100–23,000 Btu/h430
37MUHAQ24AA3Bryant, Carrier +3 more16–18.79–10.519,100–21,600 Btu/h41
A-VXP24SA-1Century, Comfort Aire +1 more16–18.39.5–10.519,600–21,600 Btu/h12
ACIQ-24-HPDACiQ, 1HVAC16–18.68.9–10.519,600–21,600 Btu/h19

All 283 R-454B 2-ton units

More Lennox R-454B units

Next step