Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

(C,H,T)5H0V36*K*AAA*: R-454B heat pump

Sold as Kenmore. R-454B Ducted split system, 3-ton class, in 300 ENERGY STAR certified pairings with 16 indoor unit models.

Refrigerant
R-454B (GWP 470)
Rated cooling
34,200 Btu/h
SEER2 range
16–19.5
HSPF2 range
8.5–9.5
Heat at 5°F
24,400–26,000 Btu/h
Cold-climate pairings
300 of 300
Compressor
Continuously variable
First certified
2025-02-17

This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: Deluxe 20 VS Heat Pump. ENERGY STAR partner: Carrier Corporation.

Certified indoor matches

Top 30 of 300 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
FCMA5B60L0D*+WALLCON
—19.511.59.524,400 Btu/hYes215670624
FCMA5B48L0C*+WALLCON
—1911924,600 Btu/hYes215662852
EA*5X60M24A*+WALLCON
*80CTL1102120B*18.510.5924,600 Btu/hYes215669330
EA*5X61M24A*+WALLCON
*97CMN1202422B*18.510.5924,800 Btu/hYes215669720
FCMA5B36L0C*+WALLCON
—18.510925,600 Btu/hYes215670614
EA*5X61M24A*+WALLCON
*97CMN1002122B*18.510.5924,800 Btu/hYes215669710
EA*5X61M24A*+WALLCON
*80CTL1352422B*18.510.5924,600 Btu/hYes215669660
EA*5X61M21A*+WALLCON
*80CSU0401712A*18.510924,800 Btu/hYes215669430
EA*5X60M24A*+WALLCON
*96CTN1202422B*18.510.5924,800 Btu/hYes215669420
EA*5X60M24A*+WALLCON
*97CTN1202422A*18.510.5924,800 Btu/hYes215679591
EA*5X60M24A*+WALLCON
*97CMN1202422B*18.510924,800 Btu/hYes215669400
EA*5X61M21A*+WALLCON
*97CMN1002122B*18.510.5924,800 Btu/hYes215669580
EA*5X61M24A*+WALLCON
*80CTL0702120B*18.510924,800 Btu/hYes215669630
EA*5X61M21A*+WALLCON
*80CTL0901716B*18.510924,800 Btu/hYes215669490
EA*5X61M24A*+WALLCON
*95CSU1002122B*18.510924,600 Btu/hYes215669680
EA*5X61M24A*+WALLCON
*97CTN1202422A*18.510.5924,800 Btu/hYes215679701
EA*5X60M24A*+WALLCON
*80CTL1352422B*18.510.5924,600 Btu/hYes215669340
EA*5X61M21A*+WALLCON
*97CTN1002122A*18.510.5924,800 Btu/hYes215679661
EA*5X60M24A*+WALLCON
*80CTL0902120B*18.510.5924,600 Btu/hYes215669320
EA*5X61M21A*+WALLCON
*80CTL1102120B*18.510.5924,800 Btu/hYes215669500
EA*5X61M24A*+WALLCON
*96CTN1002122B*18.510.5924,800 Btu/hYes215669730
EA*5X61M24A*+WALLCON
*96CTN1202422B*18.510.5924,800 Btu/hYes215669740
EA*5X61M21A*+WALLCON
*96CTN1002122B*18.510.5924,800 Btu/hYes215669610
EA*5X61M24A*+WALLCON
*80CTL0902120B*18.510.5924,600 Btu/hYes215669640
EA*5X61M24A*+WALLCON
*97CTN1002122A*18.510.5924,800 Btu/hYes215679691
EA*5X61M21A*+WALLCON
*80CTL0702120B*18.510924,800 Btu/hYes215669480
EA*5X61M24A*+WALLCON
*80CTL1102120B*18.510.5924,600 Btu/hYes215669650
EA*5X60M24A*+WALLCON
*97CTN1002122A*18.510.5924,800 Btu/hYes215679581
EA*5X60M24A*+WALLCON
*95CSU0802120B*1810924,800 Btu/hYes215669350
EA*5X43M21A*+WALLCON
*80CSU0401712A*1810925,200 Btu/hYes215668954
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-454B 3-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
MCY-MUB0368HS2P-ULToshiba Carrier16.6–29.78.2–12.221,000–28,200 Btu/h7
5A6V0X36A1American Standard19.2–219.4–10.523,800–25,400 Btu/h112
5TWV0X36A1Trane19.2–219.4–10.523,800–25,400 Btu/h112
D5CSHAH33AAKAirquest, Arcoaire +11 more16.7–19.610–10.534,000–35,000 Btu/h25
SL22KLV-036-230A**Lennox16.5–20.58–10.524,400–34,000 Btu/h80
A7CP21V36P-**AAirease, Armstrong Air +1 more15.2–208.5–10.418,400–25,400 Btu/h529
EL21KLV-036-230A**Lennox15.2–208.5–10.418,400–25,400 Btu/h299
NS21H36MA5-**AGE15.2–208.5–10.418,400–24,400 Btu/h133

All 264 R-454B 3-ton units

More Kenmore R-454B units

Next step

Some links are affiliate links; we may earn a commission at no cost to you. Disclosure.