ML14KP1-048-230A**: R-454B heat pump

Sold as Lennox. R-454B Ducted split system, 4-ton class, in 24 ENERGY STAR certified pairings with 6 indoor unit models.

Refrigerant
R-454B (GWP 470)
Rated cooling
48,000 Btu/h
SEER2 range
15.2–15.5
HSPF2 range
7.8–8.2
Heat at 5°F
23,400–24,600 Btu/h
Cold-climate pairings
0 of 24
Compressor
Single stage
First certified
2025-10-27

This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: MERIT ML14KP1 Series. ENERGY STAR partner: Lennox Industries.

Certified indoor matches

Top 24 of 24 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
CBK48MVT-048-230-**
—15.512.88.224,200 Btu/hNo215746607
CBK48MVT-060-230-**
—15.5138.223,400 Btu/hNo215746608
CBK47UHET-048-230-**
—15.212.48.224,600 Btu/hNo215746605
CBK47UHET-048-460-**
—15.212.48.224,600 Btu/hNo217595410
CK40[C,U]T-60C-**+TDR
EL280UH110E60C*15.212.88.124,200 Btu/hNo215746677
CK40[C,U]T-60C-**+TDR
EL280UH110XE60C*15.212.88.124,200 Btu/hNo215746678
CK40[C,U]T-60C-**+TDR
ML180UH110V60C*15.2138.124,000 Btu/hNo215746686
CK40[C,U]T-60C-**+TDR
EL196UH090XE48C*15.212.8824,200 Btu/hNo215746674
CK40[C,U]T-60C-**+TDR
EL280UH110E48C*15.213823,800 Btu/hNo215746676
CK40[C,U]T-60C-**+TDR
ML180UH090E60C*15.212.8824,200 Btu/hNo215746684
CK40[C,U]T-60C-**+TDR
ML180UH110E60C*15.212.8824,000 Btu/hNo215746685
CK40[C,U]T-60C-**+TDR
ML180UH110XE60C*15.212.8824,000 Btu/hNo215746687
CK40[C,U]T-60C-**+TDR
ML193UH090XE48C*15.212.8824,200 Btu/hNo215746688
CK40[C,U]T-60C-**+TDR
ML193UH110XE48C*15.212.8823,800 Btu/hNo215746689
CK40[C,U]T-60C-**+TDR
ML193UH110XE60C*15.212.8824,000 Btu/hNo215746690
CK40[C,U]T-60C-**+TDR
SL280UH080NV60C*15.212.6824,200 Btu/hNo215746695
CK40[C,U]T-60C-**+TDR
SL280UH100NV60C*15.212.8824,000 Btu/hNo215746698
CK40[C,U]T-60C-**+TDR
SL280UH110V60C*15.212.8824,000 Btu/hNo215746699
CK40[C,U]T-60C-**+TDR
EL297UH090XE48C*15.212.8824,200 Btu/hNo215746906
CK40[C,U]T-60C-**+TDR
ML196UH090XE48C*15.212.8824,200 Btu/hNo215746908
CK40[C,U]T-49C-**+TDR
EL280UH110E48C*15.2137.824,000 Btu/hNo215746612
CK40[C,U]T-49C-**+TDR
ML180UH110V60C*15.212.87.824,000 Btu/hNo215746624
CK40[C,U]T-49C-**+TDR
ML193UH110XE48C*15.212.87.824,000 Btu/hNo215746627
CK40[C,U]T-60C-**+TDR
EL297UH090XV36C*15.212.67.824,000 Btu/hNo215746907
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-454B 4-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
BOHA-60MTB-M18SBosch16–19.58.1–10.131,000–45,000 Btu/h24
MDV-V48WMN10TMidea16–208.9–10.135,000–41,000 Btu/h7
MDV-V60WMN10T(B)Midea16–19.58.1–10.131,000–45,000 Btu/h22
249VAN048**AA*Bryant15.2–198.5–1036,000–41,500 Btu/h517
27VPA948A*030*Carrier15.2–198.5–1036,000–41,500 Btu/h534
5A6V0X48A1American Standard19.4–20.89.4–1032,600–34,800 Btu/h137
5TWV0X48A1Trane19.4–20.89.4–1032,600–34,800 Btu/h137
EODA19H-4860AB*Ecoer15.2–198.3–1028,000–38,500 Btu/h59

All 274 R-454B 4-ton units

More Lennox R-454B units