Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

27SCA536A**30*: R-454B heat pump

Sold as Carrier. R-454B Ducted split system, 3-ton class, in 31 ENERGY STAR certified pairings with 16 indoor unit models.

Refrigerant
R-454B (GWP 470)
Rated cooling
35,000 Btu/h
SEER2 range
15.2–16
HSPF2 range
7.8–8
Heat at 5°F
16,100–18,100 Btu/h
Cold-climate pairings
0 of 31
Compressor
Single stage
First certified
2025-01-29

This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: COMFORT 15 SEER2 HP. ENERGY STAR partner: Carrier Corporation.

Certified indoor matches

Top 30 of 31 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
FEVA0048**+NAVA54801CK
—1613817,400 Btu/hNo217051631
FT5AN(B,X)C48L*
—15.512.57.816,700 Btu/hNo214179921
FJ5AN*C48L*
—15.5137.817,400 Btu/hNo214180168
FEVB0048**+NAVA54801CK
—15.512.57.817,400 Btu/hNo214277589
FG5ANXC48L*
—15.512.57.816,700 Btu/hNo214276886
FMA5X36**AL*
—15.512.57.817,000 Btu/hNo214424283
F55AA*C48L*
—15.5137.817,400 Btu/hNo216463995
FM(C,U)5S36**AL*
—15.212817,300 Btu/hNo218452400
CAA**4821AM*
58SU*B060M17**1615.2127.817,600 Btu/hNo214141625
CAA**4821AM*
59SU5B100M21**2215.2127.817,600 Btu/hNo214142628
CAA**4821AM*
58TN*B110C21**2015.2127.817,500 Btu/hNo214141829
CAA**4821AM*
58TP*B090V21**2015.2127.817,500 Btu/hNo214141938
CAA**4821AM*
59TP6C100V21**2215.211.77.817,500 Btu/hNo214142854
CAA**4821AM*
58S(B,C)*B090M21**2015.2127.817,500 Btu/hNo214141333
CAA**4321AM*
59SC2E100M21**2015.2127.817,900 Btu/hNo214140506
CAA**4821AM*
58S(B,C)*B110M21**2015.2127.817,600 Btu/hNo214141363
CAA**4821AM*
59SC2E100M21**2015.2127.817,600 Btu/hNo214142252
CAA**4821AM*
58SP*B090V21**2015.2127.817,500 Btu/hNo214141447
CVAMA4421XMA*
58SU*A040E17**1215.2127.818,100 Btu/hNo214143041
CAA**4321AM*
58CU*A100C21**2015.2127.817,600 Btu/hNo214139778
CAA**3721AM*
58CU*A060C17**1615.2127.817,100 Btu/hNo214138079
CAA**4321AM*
58CU*A060C17**1615.2127.817,000 Btu/hNo214139751
CAA**3721AM*
58S(B,C)*B090M21**2015.2127.817,900 Btu/hNo214138223
CAA**4821AM*
58SU*B080M21**2015.2127.817,300 Btu/hNo214141657
CAA**4321AM*
58S(B,C)*B110M21**2015.2127.818,000 Btu/hNo214139969
CAA**4321AM*
58S(B,C)*B090M21**2015.2127.817,900 Btu/hNo214139939
CVAVA4224XMA*
58SU*B100M21**2015.2127.818,100 Btu/hNo214144586
FJ5AN*C42L*
—15.212.57.816,100 Btu/hNo214179884
F55AA*C42L*
—15.212.57.816,100 Btu/hNo216463968
FM(C,U)5Z36**AL*
—15.212.57.817,200 Btu/hNo215829095
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-454B 3-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
MCY-MUB0368HS2P-ULToshiba Carrier16.6–29.78.2–12.221,000–28,200 Btu/h7
5A6V0X36A1American Standard19.2–219.4–10.523,800–25,400 Btu/h112
5TWV0X36A1Trane19.2–219.4–10.523,800–25,400 Btu/h112
D5CSHAH33AAKAirquest, Arcoaire +11 more16.7–19.610–10.534,000–35,000 Btu/h25
SL22KLV-036-230A**Lennox16.5–20.58–10.524,400–34,000 Btu/h80
A7CP21V36P-**AAirease, Armstrong Air +1 more15.2–208.5–10.418,400–25,400 Btu/h529
EL21KLV-036-230A**Lennox15.2–208.5–10.418,400–25,400 Btu/h299
NS21H36MA5-**AGE15.2–208.5–10.418,400–24,400 Btu/h133

All 264 R-454B 3-ton units

More Carrier R-454B units

Next step

Some links are affiliate links; we may earn a commission at no cost to you. Disclosure.