Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

NS22H48MA4-**A: R-410A heat pump

Sold as GE. R-410A Ducted split system, 4-ton class, in 28 ENERGY STAR certified pairings with 6 indoor unit models.

Refrigerant
R-410A (GWP 2,088)
Rated cooling
47,000 Btu/h
SEER2 range
18.5–19.5
HSPF2 range
7.8–8.5
Heat at 5°F
22,600–25,200 Btu/h
Cold-climate pairings
0 of 28
Compressor
Continuously variable
First certified
2026-05-27

This is an R-410A unit. New R-410A split systems stopped being made or imported on January 1, 2025. Under EPA's May 2026 rule, a complete system can still be installed only if every component was made or imported before 2025, and a newer R-410A condensing unit must be labeled "For servicing existing equipment only". State rules can be stricter. What that means for a quote.

Series: NS22H Series. ENERGY STAR partner: Lennox Industries.

Certified indoor matches

Top 28 of 28 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
NAM60V2TA4
—19.5128.523,200 Btu/hNo212403797
NCUU60CP4+TDR+TXV
NF97U110M5C19128.524,800 Btu/hNo212403833
NCUC60CT4+TDR
NF97U110M5C19128.524,800 Btu/hNo212403825
NAM48V2TA4
—1912822,600 Btu/hNo212403799
NCHC48CT4+TDR
NF97U110M5C19127.824,000 Btu/hNo212403807
NCHC51CT4+TDR
NF97U110M5C19127.824,400 Btu/hNo212403816
NCHC48CT4+TDR
NF96U110V5C19127.824,000 Btu/hNo212403804
NCHC51CT4+TDR
NF97U090M5C19127.824,400 Btu/hNo212403815
NCHC51CT4+TDR
NF96U110V5C19127.824,400 Btu/hNo212403813
NCUU60CP4+TDR+TXV
NF96U110V5C18.5128.525,000 Btu/hNo212403830
NCUU60CP4+TDR+TXV
NF97U090M5C18.5128.525,000 Btu/hNo212403832
NCUC60CT4+TDR
NF96U110V5C18.5128.525,000 Btu/hNo212403822
NCUC60CT4+TDR
NF97U090M5C18.5128.525,000 Btu/hNo212403824
NCUU60CP4+TDR+TXV
NF97X080V5C18.511.78.225,000 Btu/hNo212403835
NCUC60CT4+TDR
NF97X080V4C18.5128.225,000 Btu/hNo212403826
NCUC60CT4+TDR
NF96U090V5C18.5128.225,000 Btu/hNo212403821
NCUC60CT4+TDR
NF97X080V5C18.511.78.225,000 Btu/hNo212403827
NCUC60CT4+TDR
NF97U090M4C18.511.78.225,200 Btu/hNo212403823
NCUU60CP4+TDR+TXV
NF97X080V4C18.5128.225,000 Btu/hNo212403834
NCUU60CP4+TDR+TXV
NF97U090M4C18.511.78.225,200 Btu/hNo212403831
NCUU60CP4+TDR+TXV
NF96U090V5C18.5128.225,000 Btu/hNo212403829
NCHC51CT4+TDR
NF97X080V5C18.5127.824,400 Btu/hNo212403818
NCHC51CT4+TDR
NF97X080V4C18.5127.824,400 Btu/hNo212403817
NCHC48CT4+TDR
NF97U090M5C18.5127.824,000 Btu/hNo212403806
NCHC51CT4+TDR
NF97U090M4C18.5127.824,600 Btu/hNo212403814
NCHC48CT4+TDR
NF97X080V4C18.5127.824,200 Btu/hNo212403808
NCHC51CT4+TDR
NF96U090V5C18.5127.824,400 Btu/hNo212403812
NCHC48CT4+TDR
NF96U090V5C18.5127.824,200 Btu/hNo212403803
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-410A 4-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
38MURAQ48AB3Bryant, Carrier +10 more15.6–15.99.4–9.646,000–46,500 Btu/h20
DLCURAH48ABKAirquest, Arcoaire +13 more15.6–15.99.4–9.646,000–46,500 Btu/h34
MOE30U-48HFN1-M-[X1]MDV, Mits Air +2 more15.6–15.99.4–9.646,000–46,500 Btu/h5
EODA19H-4860AA*Ecoer15.2–19.58.3–9.528,000–38,500 Btu/h34
YOHA2-60AAYISO15.2–19.58.3–9.528,000–38,500 Btu/h34
A-VCD48SA-1Comfort Aire, Comfort-Aire +1 more15.69.446,000 Btu/h5
ACIQ-48-HPB1HVAC, ACiQ +1 more15.69.446,000 Btu/h3
EZ-48-HP1HVAC, Diycool +2 more15.69.446,000 Btu/h4

All 129 R-410A 4-ton units

More GE R-410A units

Next step