Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

YOHA2-60AA: R-410A heat pump

Sold as YISO. R-410A Ducted split system, 4-ton class, in 34 ENERGY STAR certified pairings with 16 indoor unit models.

Refrigerant
R-410A (GWP 2,088)
Rated cooling
45,000 Btu/h
SEER2 range
15.2–19.5
HSPF2 range
8.3–9.5
Heat at 5°F
28,000–38,500 Btu/h
Cold-climate pairings
34 of 34
Compressor
Continuously variable
First certified
2026-06-02

This is an R-410A unit. New R-410A split systems stopped being made or imported on January 1, 2025. Under EPA's May 2026 rule, a complete system can still be installed only if every component was made or imported before 2025, and a newer R-410A condensing unit must be labeled "For servicing existing equipment only". State rules can be stricter. What that means for a quote.

Series: Pro. ENERGY STAR partner: Yiso (Guangdong) Smart Technology Co.,Ltd.

3 indoor model(s) in this list also appear in certified R-410A pairings, usually with a different expansion valve or sensor kit fitted at install. That doesn't mean an installed coil can be switched between refrigerants.

Certified indoor matches

Top 30 of 34 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
YAHA1-36BA
—19.512.59.529,200 Btu/hYes214290151
YAHA2-36CB
—19.512.59.529,200 Btu/hYes216558234
YAHA1-48BA
—1912.59.534,400 Btu/hYes214290128
YAHA2-48CB
—1912.59.534,400 Btu/hYes216558235
YAHA1-60BA
—18.511.79.538,500 Btu/hYes214290129
YAHA2-60CB
—18.511.79.538,500 Btu/hYes216558236
YAHA2-36AA
—18.2129.529,200 Btu/hYes216019256
YLCN2-3036BA
MGH96M080B3A1812928,000 Btu/hYes214290144
YLCN2-3036BA
MGH96M060B3A1812928,000 Btu/hYes214290145
YLCN2-3036BA
FG7TC-060D-V24B*1812928,000 Btu/hYes215447621
YLSN2-3036CA
FG7TC-080D-V35C*1812928,000 Btu/hYes217477681
YLSN2-3036CA
MGH96M080C4A1812928,000 Btu/hYes217477683
YLCN2-4248CA
MGH96M100C5A1811.78.832,400 Btu/hYes214290146
YLCN2-4248CA
FG7TC-100D-V35C*1811.78.832,400 Btu/hYes215447622
YLCN2-4248CA
FG7TC-080D-V35C*1811.78.832,400 Btu/hYes215447623
YLCN2-4860CA
MGH96M100C5A1811.48.737,800 Btu/hYes214290148
YLCN2-4860DA
MGH96M120D5A1811.78.737,800 Btu/hYes214290149
YLCN2-4860DA
MGH96M100D5A1811.78.737,800 Btu/hYes214290150
YLCN2-4860CA
FG7TC-100D-V35C*1811.48.737,800 Btu/hYes215447624
YLCN2-4860DA
FG7TC-120D-E45D*1811.78.737,800 Btu/hYes215447625
YLCN2-4248CA
MGH96M080C4A17.511.78.832,400 Btu/hYes214290147
YAHA2-60AA
—17119.238,500 Btu/hYes216019255
YLCN2-3036BA
FG7SA-090C-T24B*17128.528,000 Btu/hYes214838753
YLCN2-3036BA
FG7SA-072C-T24B*17128.528,000 Btu/hYes214838754
YLCN2-4248CA
FG7SA-108C-T35C*1711.78.332,400 Btu/hYes214838755
YLCN2-4248CA
FG7SA-090C-T35C*1711.78.332,400 Btu/hYes214838756
YLCN2-4860CA
FG7SA-108C-T35C*16.511.48.337,800 Btu/hYes214838757
YLCN2-4860CA
FG7SA-090C-T35C*16.511.28.337,800 Btu/hYes215213673
YLCN2-4860CA
—16118.637,200 Btu/hYes216706467
YLCN2-4860DA
—16118.637,200 Btu/hYes216706468
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-410A 4-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
38MURAQ48AB3Bryant, Carrier +10 more15.6–15.99.4–9.646,000–46,500 Btu/h20
DLCURAH48ABKAirquest, Arcoaire +13 more15.6–15.99.4–9.646,000–46,500 Btu/h34
MOE30U-48HFN1-M-[X1]MDV, Mits Air +2 more15.6–15.99.4–9.646,000–46,500 Btu/h5
EODA19H-4860AA*Ecoer15.2–19.58.3–9.528,000–38,500 Btu/h34
A-VCD48SA-1Comfort Aire, Comfort-Aire +1 more15.69.446,000 Btu/h5
ACIQ-48-HPB1HVAC, ACiQ +1 more15.69.446,000 Btu/h3
EZ-48-HP1HVAC, Diycool +2 more15.69.446,000 Btu/h4
MOE30U-45HFN1-MMDV, Alsetria +1 more15.29.246,500 Btu/h3

All 129 R-410A 4-ton units

More YISO R-410A units

Next step