Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

EODA19H-4860AA*: R-410A heat pump

Sold as Ecoer. R-410A Ducted split system, 4-ton class, in 34 ENERGY STAR certified pairings with 16 indoor unit models.

Refrigerant
R-410A (GWP 2,088)
Rated cooling
45,000 Btu/h
SEER2 range
15.2–19.5
HSPF2 range
8.3–9.5
Heat at 5°F
28,000–38,500 Btu/h
Cold-climate pairings
34 of 34
Compressor
Continuously variable
First certified
2026-06-02

This is an R-410A unit. New R-410A split systems stopped being made or imported on January 1, 2025. Under EPA's May 2026 rule, a complete system can still be installed only if every component was made or imported before 2025, and a newer R-410A condensing unit must be labeled "For servicing existing equipment only". State rules can be stricter. What that means for a quote.

Series: TDi Pro. ENERGY STAR partner: Ecoer Inc..

3 indoor model(s) in this list also appear in certified R-410A pairings, usually with a different expansion valve or sensor kit fitted at install. That doesn't mean an installed coil can be switched between refrigerants.

Certified indoor matches

Top 30 of 34 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
EAHATN-36BA*
—19.512.59.529,200 Btu/hYes214660564
EAHDEN-36AB*
—19.512.59.529,200 Btu/hYes216558239
EAHATN-48BA*
—1912.59.534,400 Btu/hYes214660541
EAHDEN-48AB*
—1912.59.534,400 Btu/hYes216558240
EAHATN-60BA*
—18.511.79.538,500 Btu/hYes214660542
EAHDEN-60AB*
—18.511.79.538,500 Btu/hYes216558241
EAHAEC-36
—18.2129.529,200 Btu/hYes216019258
GNC3036BPT
MGH96M060B3A1812928,000 Btu/hYes214660558
GNC3036BPT
MGH96M080B3A1812928,000 Btu/hYes214660557
GNC3036BPT
FG7TC-060D-V24B*1812928,000 Btu/hYes215447633
SNC36CPT
FG7TC-080D-V35C*1812928,000 Btu/hYes217477693
SNC36CPT
MGH96M080C4A1812928,000 Btu/hYes217477695
GNC4248CPT
MGH96M100C5A1811.78.832,400 Btu/hYes214660559
GNC4248CPT
FG7TC-100D-V35C*1811.78.832,400 Btu/hYes215447634
GNC4248CPT
FG7TC-080D-V35C*1811.78.832,400 Btu/hYes215447635
GNC4860DPT
MGH96M100D5A1811.78.737,800 Btu/hYes214660563
GNC4860DPT
MGH96M120D5A1811.78.737,800 Btu/hYes214660562
GNC4860CPT
MGH96M100C5A1811.48.737,800 Btu/hYes214660561
GNC4860CPT
FG7TC-100D-V35C*1811.48.737,800 Btu/hYes215447636
GNC4860DPT
FG7TC-120D-E45D*1811.78.737,800 Btu/hYes215447637
GNC4248CPT
MGH96M080C4A17.511.78.832,400 Btu/hYes214660560
EAHAEC-60
—17119.238,500 Btu/hYes216019257
GNC3036BPT
FG7SA-090C-T24B*17128.528,000 Btu/hYes214838775
GNC3036BPT
FG7SA-072C-T24B*17128.528,000 Btu/hYes214838776
GNC4248CPT
FG7SA-108C-T35C*1711.78.332,400 Btu/hYes214838777
GNC4248CPT
FG7SA-090C-T35C*1711.78.332,400 Btu/hYes214838778
GNC4860CPT
FG7SA-108C-T35C*16.511.48.337,800 Btu/hYes214838779
GNC4860CPT
FG7SA-090C-T35C*16.511.28.337,800 Btu/hYes215213674
GNC4860DPT
—16118.637,200 Btu/hYes216706474
GNC4860CPT
—16118.637,200 Btu/hYes216706473
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-410A 4-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
38MURAQ48AB3Bryant, Carrier +10 more15.6–15.99.4–9.646,000–46,500 Btu/h20
DLCURAH48ABKAirquest, Arcoaire +13 more15.6–15.99.4–9.646,000–46,500 Btu/h34
MOE30U-48HFN1-M-[X1]MDV, Mits Air +2 more15.6–15.99.4–9.646,000–46,500 Btu/h5
YOHA2-60AAYISO15.2–19.58.3–9.528,000–38,500 Btu/h34
A-VCD48SA-1Comfort Aire, Comfort-Aire +1 more15.69.446,000 Btu/h5
ACIQ-48-HPB1HVAC, ACiQ +1 more15.69.446,000 Btu/h3
EZ-48-HP1HVAC, Diycool +2 more15.69.446,000 Btu/h4
MOE30U-45HFN1-MMDV, Alsetria +1 more15.29.246,500 Btu/h3

All 129 R-410A 4-ton units

More Ecoer R-410A units

Next step

Some links are affiliate links; we may earn a commission at no cost to you. Disclosure.