Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

NS22H36MA4-**A: R-410A heat pump

Sold as GE. R-410A Ducted split system, 3-ton class, in 73 ENERGY STAR certified pairings with 15 indoor unit models.

Refrigerant
R-410A (GWP 2,088)
Rated cooling
35,400 Btu/h
SEER2 range
17.5–20.5
HSPF2 range
8.5–9
Heat at 5°F
17,800–18,600 Btu/h
Cold-climate pairings
0 of 73
Compressor
Continuously variable
First certified
2026-05-27

This is an R-410A unit. New R-410A split systems stopped being made or imported on January 1, 2025. Under EPA's May 2026 rule, a complete system can still be installed only if every component was made or imported before 2025, and a newer R-410A condensing unit must be labeled "For servicing existing equipment only". State rules can be stricter. What that means for a quote.

Series: NS22H SERIES. ENERGY STAR partner: Lennox Industries.

Certified indoor matches

Top 30 of 73 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
NCUC48CT4+TDR
NF96U110V5C20.5128.818,200 Btu/hNo212403899
NCUC48CT4+TDR
NF97U090M4C20.5128.818,400 Btu/hNo212403901
NCUU48CP4+TDR+TXV
NF97U110M5C20.5128.818,100 Btu/hNo212403937
NCUU48CP4+TDR+TXV
NF97U090M4C20.5128.818,400 Btu/hNo212403935
NCUC48CT4+TDR
NF97U110M5C20.5128.818,100 Btu/hNo212403903
NCUU48CP4+TDR+TXV
NF96U110V5C20.5128.818,200 Btu/hNo212403933
NAM42V2TA4
—2011.7918,300 Btu/hNo212403841
NAM36V2TA4
—2012918,200 Btu/hNo212403838
NCUC48CT4+TDR
NF97X080V4C20128.818,300 Btu/hNo212403904
NCUC48CT4+TDR
NF96U090V5C20128.818,200 Btu/hNo212403898
NCUU48CP4+TDR+TXV
NF97X080V4C20128.818,300 Btu/hNo212403938
NCUU48CP4+TDR+TXV
NF97X080V5C20128.818,400 Btu/hNo212403939
NCUC48CT4+TDR
NF96U090V3C20128.818,300 Btu/hNo212403897
NCUU48CP4+TDR+TXV
NF97U090M3C20128.818,300 Btu/hNo212403934
NCUC48CT4+TDR
NF97U090M5C20128.818,300 Btu/hNo212403902
NCUU48CP4+TDR+TXV
NF96U090V5C20128.818,200 Btu/hNo212403932
NCUC48CT4+TDR
NF97X080V5C20128.818,400 Btu/hNo212403905
NCUU48CP4+TDR+TXV
NF96U090V3C20128.818,300 Btu/hNo212403931
NCUC48CT4+TDR
NF97U090M3C20128.818,300 Btu/hNo212403900
NCUU48CP4+TDR+TXV
NF97U090M5C20128.818,300 Btu/hNo212403936
NCUC36BT4+TDR
NF97U070M3B20128.518,000 Btu/hNo212403885
NCHC36CT4+TDR
NF97U110M5C2011.78.517,900 Btu/hNo212403858
NCHC36CT4+TDR
NF97X080V5C2011.78.518,300 Btu/hNo212403860
NCUC36BT4+TDR
NF96U070V3B20128.518,000 Btu/hNo212403884
NCUU36BP4+TDR+TXV
NF97X060V3B2011.78.518,000 Btu/hNo212403921
NCUU36BP4+TDR+TXV
NF96U070V3B20128.518,000 Btu/hNo212403918
NCHC36CT4+TDR
NF96U110V5C2011.78.518,000 Btu/hNo212403854
NCUC36BT4+TDR
NF97X060V3B2011.78.518,000 Btu/hNo212403887
NCUU36BP4+TDR+TXV
NF97X040V3B20128.518,000 Btu/hNo212403920
NCUU36BP4+TDR+TXV
NF97U070M3B20128.518,000 Btu/hNo212403919
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-410A 3-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
38MURAQ36AB3Bryant, Carrier +10 more15.2–168.6–1031,600–34,400 Btu/h25
A-KCD36SA-1KERR15.2–168.6–1031,600–34,400 Btu/h4
A-VCD36SA-1Comfort Aire, Comfort-Aire +1 more15.2–168.6–1031,600–34,400 Btu/h11
ACIQ-36-HPB1HVAC, ACiQ +3 more15.2–17.68.6–1031,600–36,000 Btu/h23
AZPN/36WDKepler15.2–168.6–1031,600–34,400 Btu/h4
BMAH3618CBlueridge15.2–168.6–1031,600–34,400 Btu/h3
BZ33-INV36OUT2-JBreeze3315.2–17.68.6–1031,600–33,400 Btu/h3
CCOXHA24V36HPCustom Comfort15.2–168.6–1031,600–34,400 Btu/h4

All 138 R-410A 3-ton units

More GE R-410A units

Next step

Some links are affiliate links; we may earn a commission at no cost to you. Disclosure.