Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

(C,H,T)5H8T48*K*AAA*: R-454B heat pump

Sold as Kenmore. R-454B Ducted split system, 4-ton class, in 413 ENERGY STAR certified pairings with 41 indoor unit models.

Refrigerant
R-454B (GWP 470)
Rated cooling
48,000 Btu/h
SEER2 range
15.2–18
HSPF2 range
7.8–8.5
Heat at 5°F
23,200–26,600 Btu/h
Cold-climate pairings
0 of 413
Compressor
Two-stage
First certified
2025-01-30

This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: Mainline 18 SEER2 HP. ENERGY STAR partner: Carrier Corporation.

Certified indoor matches

Top 30 of 413 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
FTMA5B60L0D*
—1813.58.124,600 Btu/hNo216152752
EVD5X61M21A*+WALLCON
*80CSU0802120B*1813823,400 Btu/hNo216351213
EVD5X61M24A*+WALLCON
*97CMN1002122B*1813823,600 Btu/hNo216351349
EVD5X61M24A*+WALLCON
*80CTL0902120B*1813823,400 Btu/hNo216351301
EVD5X61M24A*+WALLCON
*80CTL1352422B*1813823,400 Btu/hNo216351309
EVD5X61M24A*+WALLCON
*80CSU1002120B*1813823,600 Btu/hNo216351477
EVD5X61M24A*+WALLCON
*96CTN1002122B*1813823,600 Btu/hNo216351421
EVD5X61M24A*+WALLCON
*96CTN1202422B*1813823,600 Btu/hNo216351429
EVD5X61M24A*+WALLCON
*80CSU0802120B*1813823,400 Btu/hNo216351469
EVD5X61M24A*+WALLCON
*97CTN1002122A*1813823,600 Btu/hNo216351493
EVD5X61M24A*+WALLCON
*97CTN1202422A*1813823,600 Btu/hNo216351501
EVD5X61M21A*+WALLCON
*80CTL0902120B*1813823,600 Btu/hNo216351060
EVD5X61M21A*+WALLCON
*80CSU1002120A*1812825,200 Btu/hNo216351004
EVD5X61M21A*+WALLCON
*80CTL1102120B*1813823,600 Btu/hNo216351068
EVD5X61M21A*
*97VTN1002122A*17.512.58.524,600 Btu/hNo216351261
EVD5X61M24A*
*95MSU1002122A*17.512.58.525,000 Btu/hNo216351405
EVD5X61M24A*
*80VSL1102122B*17.512.58.525,000 Btu/hNo216351277
EVD5X61M24A*
*96VTN1002122B*17.512.58.524,800 Btu/hNo216351453
EVD5X61M24A*
*97VTN1002122A*17.512.58.524,800 Btu/hNo216351525
EVD5X61M21A*
*80MSU0802120A*17.5138.524,400 Btu/hNo216351036
EVD5X61M24A*
*80VTL1102122B*17.512.58.524,800 Btu/hNo216351325
EVD5X61M21A*
*96VTN1002122B*17.512.58.524,600 Btu/hNo216351205
EVD5X61M21A*
*80VSL1102122B*17.512.58.524,800 Btu/hNo216351020
EVD5X61M21A*
*80MSU1002120A*17.512.58.525,000 Btu/hNo216351044
EVD5X61M21A*
*95MSU1002122A*17.512.58.124,400 Btu/hNo216351165
EVD5X49M24A*
*80MSU0802120A*17.512.58.124,600 Btu/hNo216350572
EVM5X60M21A*
*80MSU0802120A*17.512.58.124,400 Btu/hNo216350020
EVM5X60M21A*
*96VTN1002122B*17.512.58.124,400 Btu/hNo216350188
EVD5X60M21A*
*96VTN1002122B*17.512.58.124,400 Btu/hNo216350932
EVD5X61M21A*
*80MSU0601716A*17.5128.125,000 Btu/hNo216351028
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-454B 4-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
BOHA-60MTB-M18SBosch16–19.58.1–10.131,000–45,000 Btu/h24
MDV-V48WMN10TMidea16–208.9–10.135,000–41,000 Btu/h7
MDV-V60WMN10T(B)Midea16–19.58.1–10.131,000–45,000 Btu/h22
249VAN048**AA*Bryant15.2–198.5–1036,000–41,500 Btu/h517
27VPA948A*030*Carrier15.2–198.5–1036,000–41,500 Btu/h534
5A6V0X48A1American Standard19.4–20.89.4–1032,600–34,800 Btu/h137
5TWV0X48A1Trane19.4–20.89.4–1032,600–34,800 Btu/h137
EODA19H-4860AB*Ecoer15.2–198.3–1028,000–38,500 Btu/h59

All 274 R-454B 4-ton units

More Kenmore R-454B units

Next step