Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

27VNA360A*030*: R-454B heat pump

Sold as Carrier. R-454B Ducted split system, 4.5-ton class, in 41 ENERGY STAR certified pairings with 4 indoor unit models.

Refrigerant
R-454B (GWP 470)
Rated cooling
56,000 Btu/h
SEER2 range
17.5–20
HSPF2 range
8–8.5
Heat at 5°F
44,500–47,500 Btu/h
Cold-climate pairings
40 of 41
Compressor
Continuously variable
First certified
2025-01-30

This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: Infinity 23 VS Heat Pump. ENERGY STAR partner: Carrier Corporation.

Certified indoor matches

Top 30 of 41 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
FE5BNBD60L*+UI
—2012.58.544,500 Btu/hYes215931484
CAA**6024AM*+UI
58CU*A080C21**201911.58.545,500 Btu/hYes215931514
CAA**6124AM*+UI
58CU*A080C21**201911.58.546,000 Btu/hYes215931664
CAA**6124AM*+UI
58CU*A100C21**2019118.546,500 Btu/hYes215931674
CAA**6124AM*+UI
58TN*B090C21**201911.58.546,500 Btu/hYes215931694
CAA**6124AM*+UI
58TN*B110C21**201911.58.546,500 Btu/hYes215931704
CAA**6124AM*+UI
58TN*B135C24**221911.78.546,000 Btu/hYes215931714
CAA**6024AM*+UI
58CU*A100C21**2018.5118.546,000 Btu/hYes215931524
CAA**6024AM*+UI
59MN7C100C21**2218.5118.546,000 Btu/hYes215931614
CAA**6024AM*+UI
59TN6C100C21**2218.5118.546,000 Btu/hYes215931634
CAA**6024AM*+UI
59TN6C120C24**2218.5118.546,000 Btu/hYes215931644
CAA**6124AM*+UI
58TN*B070C21**2018.5118.547,000 Btu/hYes215931684
CAA**6124AM*+UI
59CU5B080C21**2018.5118.546,500 Btu/hYes215931724
CAA**6124AM*+UI
59MN7C080C21**2018.5118.546,500 Btu/hYes215931744
CAA**6124AM*+UI
59MN7C100C21**2218.511.58.546,500 Btu/hYes215931754
CAA**6124AM*+UI
59MN7C120C24**2218.5118.546,500 Btu/hYes215931764
CAA**6124AM*+UI
59TN6C100C21**2218.511.58.546,500 Btu/hYes215931774
CAA**6124AM*+UI
59TN6C120C24**2218.511.58.546,500 Btu/hYes215931784
CAA**6024AM*+UI
59TN7A100C21**2218.5118.546,000 Btu/hYes217448273
CAA**6024AM*+UI
58TN*B090C21**2018.511.58.145,500 Btu/hYes215931544
CAA**6024AM*+UI
58TN*B110C21**2018.511.58.145,500 Btu/hYes215931554
CAA**6024AM*+UI
59MN7C120C24**2218.5118.146,000 Btu/hYes215931624
CAA**6024AM*+UI
58TN*B135C24**2218.511.58.145,500 Btu/hYes215931564
CAA**6024AM*+UI
59CU5B100C21**2218.511.58.145,500 Btu/hYes215931584
CAA**6024AM*+UI
58TN*B070C21**2018118.146,500 Btu/hYes215931534
CAA**6024AM*+UI
59MN7C080C21**2018118.146,000 Btu/hYes215931604
CAA**6024AM*+UI
59CU5B080C21**2018118.146,000 Btu/hYes215931574
CAA**6124AM*+UI
59MN7C060C21**201810.58.147,500 Btu/hYes215931734
CSAH*6012AM*+UI
58CU*A100C21**2018118.146,000 Btu/hYes215931804
CSAH*6012AM*+UI
58TN*B090C21**201811.58.145,500 Btu/hYes215931824
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-454B 4.5-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
27VNA154A*030*Carrier17–218–10.545,500–54,000 Btu/h155
291VAN054**AA*Bryant17–218–10.545,500–54,000 Btu/h155
MDV-V60WMN10TMidea16–19.58.9–10.142,000–45,000 Btu/h7
BOHA-60RTB-M18SBosch15.5–198–9.831,000–42,000 Btu/h19
MDV-V60WMN10T(A)Midea15.5–198–9.831,000–42,000 Btu/h17
SL22KLV-060-230A**Lennox18.2–21.18.2–9.635,400–45,500 Btu/h33
37MUHAQ60AA3Bryant, Carrier +3 more15.2–17.58.1–9.543,000–54,000 Btu/h33
ACIQ-60-HPDACiQ, 1HVAC15.2–17.58.1–9.541,000–54,000 Btu/h13

All 180 R-454B 4.5-ton units

More Carrier R-454B units

Next step