Outdoor unit · ENERGY STAR data November 12, 2026
MDV-V60WMN10T(A): R-454B heat pump
Sold as Midea. R-454B Ducted split system, 4.5-ton class, in 17 ENERGY STAR certified pairings with 11 indoor unit models.
- Refrigerant
- R-454B (GWP 470)
- Rated cooling
- 52,000 Btu/h
- SEER2 range
- 15.5–19
- HSPF2 range
- 8–9.8
- Heat at 5°F
- 31,000–42,000 Btu/h
- Cold-climate pairings
- 17 of 17
- Compressor
- Continuously variable
- First certified
- 2025-11-24
This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.
Series: ATOM X, MDV Series. ENERGY STAR partner: GD Midea Heating & Ventilating Equipment Co., Ltd..
Certified indoor matches
Top 17 of 17 pairings by SEER2. The AHRI number links to the ENERGY STAR record.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat at 5°F | Cold climate | AHRI ref # |
|---|---|---|---|---|---|---|---|
—MIDEA | — | 19 | 9.5 | 9.8 | 42,000 Btu/h | Yes | 217992176 |
—MIDEA | — | 17.8 | 9.2 | 9.4 | 42,000 Btu/h | Yes | 217992177 |
MIH48VMN10 | — | 17 | 10.2 | 9 | 39,000 Btu/h | Yes | 217992227 |
—MIDEA | — | 16.5 | 9 | 9 | 42,000 Btu/h | Yes | 217992169 |
MVME48C2MN10TB | — | 16.5 | 10 | 9 | 39,000 Btu/h | Yes | 217992225 |
MVME48C2MN10TD | — | 16.5 | 10 | 9 | 39,000 Btu/h | Yes | 218159716 |
MIH54VMN10 | — | 16.5 | 9.5 | 8.5 | 42,000 Btu/h | Yes | 217992249 |
MCPM4860CN10TH | MGV97U100C5A | 15.5 | 9.5 | 8.6 | 37,000 Btu/h | Yes | 217992220 |
MCPM4860DN10TH | MGV97U100D5A | 15.5 | 9.5 | 8.6 | 40,000 Btu/h | Yes | 217992221 |
MCPM4860DN10TH | MGV97U120D5A | 15.5 | 9.5 | 8.6 | 37,000 Btu/h | Yes | 217992222 |
MVME60C2MN10TB | — | 15.5 | 9.5 | 8.5 | 42,000 Btu/h | Yes | 217992226 |
MVME60C2MN10TD | — | 15.5 | 9.5 | 8.5 | 42,000 Btu/h | Yes | 218159717 |
MC**4248BN10TH | MGV97U080B3A | 15.5 | 10 | 8.1 | 31,000 Btu/h | Yes | 217992215 |
MC**4248CN10TH | MGV97U080C4A | 15.5 | 10 | 8.1 | 31,600 Btu/h | Yes | 217992216 |
MC**4248CN10TH | MGV97U100C5A | 15.5 | 10 | 8.1 | 33,000 Btu/h | Yes | 217992217 |
MC**4248DN10TH | MGV97U100D5A | 15.5 | 10 | 8.1 | 33,000 Btu/h | Yes | 217992218 |
MC**4248DN10TH | MGV97U120D5A | 15.5 | 10 | 8 | 33,000 Btu/h | Yes | 217992219 |
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.
Other R-454B 4.5-ton units
| Outdoor unit | Brand | SEER2 | HSPF2 | Heat at 5°F | Certified pairings |
|---|---|---|---|---|---|
27VNA154A*030* | Carrier | 17–21 | 8–10.5 | 45,500–54,000 Btu/h | 155 |
291VAN054**AA* | Bryant | 17–21 | 8–10.5 | 45,500–54,000 Btu/h | 155 |
MDV-V60WMN10T | Midea | 16–19.5 | 8.9–10.1 | 42,000–45,000 Btu/h | 7 |
BOHA-60RTB-M18S | Bosch | 15.5–19 | 8–9.8 | 31,000–42,000 Btu/h | 19 |
SL22KLV-060-230A** | Lennox | 18.2–21.1 | 8.2–9.6 | 35,400–45,500 Btu/h | 33 |
37MUHAQ60AA3 | Bryant, Carrier +3 more | 15.2–17.5 | 8.1–9.5 | 43,000–54,000 Btu/h | 33 |
ACIQ-60-HPD | ACiQ, 1HVAC | 15.2–17.5 | 8.1–9.5 | 41,000–54,000 Btu/h | 13 |
AUO19-60N2-M3H | AI Air Conditioning | 15.2–17.5 | 8.1–9.5 | 43,000–54,000 Btu/h | 4 |