Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

YH648E2S11: R-454B heat pump

Sold as York. R-454B Ducted split system, 4-ton class, in 554 ENERGY STAR certified pairings with 141 indoor unit models.

Refrigerant
R-454B (GWP 470)
Rated cooling
47,000 Btu/h
SEER2 range
15.2–16
HSPF2 range
7.8–8.1
Heat at 5°F
25,000–27,800 Btu/h
Cold-climate pairings
0 of 554
Compressor
Two-stage
First certified
2025-04-11

This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: LX SERIES. ENERGY STAR partner: Johnson Controls, Inc..

Certified indoor matches

Top 30 of 554 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
CTU60D5XHS1+JMC20D2SN1+TXV
—16128.127,000 Btu/hNo217019148
CTF60D5CHS1+JME18D2SN1
—16128.126,800 Btu/hNo217019150
CTU60D5XHS1+JME18D2SN1+TXV
—16128.126,800 Btu/hNo217019152
CTF60C5CHS1
Y81E100C20SMPS116128.127,400 Btu/hNo217019154
CTF60C5CHS1
Y81E100C20LMPS116128.127,400 Btu/hNo217019156
CTF60C5CHS1
Y92E100C16SMPS116128.127,600 Btu/hNo217019158
CTF60C5CHS1
Y82E120C20LMPS116128.127,400 Btu/hNo217019160
JHC60C5CH2SS1
—16128.127,000 Btu/hNo217019162
CTM60C5CHS1+JMET12CS2N1
—16128.126,400 Btu/hNo217019164
CTM60C5CHS1+JMVT17CC2N1
—16128.126,600 Btu/hNo217019166
CTM60C5CHS1+JME12C2SN1
—16128.126,400 Btu/hNo217019168
CTM60C5CHS1
Y92E100C16SMPS116128.127,200 Btu/hNo217019170
CTM60D5CHS1
Y92E120D20SMPS116128.127,400 Btu/hNo217019172
CTF60C5CGS1
Y92E100C16SMPS11611.78.127,400 Btu/hNo217019174
CTU60C5XGS1+TXV
Y92E100C16SMPS11611.78.127,400 Btu/hNo217019176
CTU60D5XGS1+JMC20D2SN1+TXV
—16128.127,200 Btu/hNo217019184
CTF60C5CGS1+JMVT17CC2N1
—16128.127,200 Btu/hNo217019178
CTU60C5XGS1+JMVT17CC2N1+TXV
—16128.127,200 Btu/hNo217019180
CTF60D5CGS1+JMC20D2SN1
—16128.127,200 Btu/hNo217019182
CTF60C5CGS1
Y81E100C20SMPS116128.127,200 Btu/hNo217019186
CTF60C5CGS1
Y81E100C20LMPS116128.127,200 Btu/hNo217019188
CTU60C5XGS1+TXV
Y81E100C20SMPS116128.127,200 Btu/hNo217019190
CTU60C5XGS1+TXV
Y81E100C20LMPS116128.127,200 Btu/hNo217019192
CTF60C5CGS1
Y92E100C20SMPS116128.127,400 Btu/hNo217019194
CTU60C5XGS1+TXV
Y92E100C20SMPS116128.127,400 Btu/hNo217019196
CTF60C5CGS1
Y82E120C20LMPS116128.127,600 Btu/hNo217019198
CTU60C5XGS1+TXV
Y82E120C20LMPS116128.127,600 Btu/hNo217019200
CTF60C5CHS1
Y81E120C20SMPS116128.127,400 Btu/hNo217019202
CTF60C5CHS1
Y81E120C20LMPS116128.127,400 Btu/hNo217019204
CTF60C5CHS1
Y82E100C20LMPS116128.127,400 Btu/hNo217019206
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-454B 4-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
BOHA-60MTB-M18SBosch16–19.58.1–10.131,000–45,000 Btu/h24
MDV-V48WMN10TMidea16–208.9–10.135,000–41,000 Btu/h7
MDV-V60WMN10T(B)Midea16–19.58.1–10.131,000–45,000 Btu/h22
249VAN048**AA*Bryant15.2–198.5–1036,000–41,500 Btu/h517
27VPA948A*030*Carrier15.2–198.5–1036,000–41,500 Btu/h534
5A6V0X48A1American Standard19.4–20.89.4–1032,600–34,800 Btu/h137
5TWV0X48A1Trane19.4–20.89.4–1032,600–34,800 Btu/h137
EODA19H-4860AB*Ecoer15.2–198.3–1028,000–38,500 Btu/h59

All 274 R-454B 4-ton units

More York R-454B units

Next step