Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

ML17XP1-042-230A**: R-410A heat pump

Sold as Lennox. R-410A Ducted split system, 3.5-ton class, in 206 ENERGY STAR certified pairings with 29 indoor unit models.

Refrigerant
R-410A (GWP 2,088)
Rated cooling
41,500 Btu/h
SEER2 range
15.2–15.6
HSPF2 range
7.8–8.3
Heat at 5°F
10,400–22,000 Btu/h
Cold-climate pairings
0 of 206
Compressor
Single stage
First certified
2025-07-25

This is an R-410A unit. New R-410A split systems stopped being made or imported on January 1, 2025. Under EPA's May 2026 rule, a complete system can still be installed only if every component was made or imported before 2025, and a newer R-410A condensing unit must be labeled "For servicing existing equipment only". State rules can be stricter. What that means for a quote.

Series: MERIT ML17XP1 Series. ENERGY STAR partner: Lennox Industries.

Certified indoor matches

Top 30 of 206 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
CBA27UHE-042-230*+TDR
—15.6138.322,000 Btu/hNo210049508
CBA38MV-042-230*+TDR
—15.6138.320,600 Btu/hNo210049509
CRX35-48C-**-*+TDR
ML180DF110E60C*15.6138.321,800 Btu/hNo213258050
CK40DT-48C-0*+TDR
ML180DF110E60C*15.6138.321,800 Btu/hNo214624297
CBK47UHET-042-230-0*
—15.6138.322,000 Btu/hNo214861207
CX35-49C+TDR
ML180UH110V60C*15.6137.819,900 Btu/hNo210049579
C35-49C+TDR+TXV
ML180UH110V60C*15.6137.819,900 Btu/hNo210049479
C35-49C+TDR+TXV
SL280UH100NV60C*15.6137.819,900 Btu/hNo210049502
CX35-49C+TDR
SL280UH100NV60C*15.6137.819,900 Btu/hNo210049596
C35-48C+TDR+TXV
SL280UH080NV60C*15.6137.819,700 Btu/hNo210857167
C35-48C+TDR+TXV
SL280UH100NV60C*15.6137.819,700 Btu/hNo210857170
C35-48C+TDR+TXV
ML180UH110V60C*15.6137.819,700 Btu/hNo210857160
C35-48C+TDR+TXV
EL280UH110XE60C*15.6137.819,600 Btu/hNo210857156
C35-48C+TDR+TXV
EL280UH110E48C*15.6137.819,600 Btu/hNo210857154
C35-48C+TDR+TXV
EL280UH110E60C*15.6137.819,600 Btu/hNo210857155
CHX35-42B-**-*+TDR
EL280UH090E48B*15.6137.819,900 Btu/hNo210869919
CHX35-42B-**-*+TDR
EL280UH090XE48B*15.6137.819,900 Btu/hNo210869920
CX35-48C+TDR
EL280UH110E60C*15.6137.819,600 Btu/hNo210869935
CX35-48C+TDR
EL280UH110E48C*15.6137.819,600 Btu/hNo210869934
CX35-48C+TDR
EL280UH110XE60C*15.6137.819,600 Btu/hNo210869936
CX35-48C+TDR
ML180UH110V60C*15.6137.819,700 Btu/hNo210869940
CX35-48C+TDR
SL280UH080NV60C*15.6137.819,700 Btu/hNo210869947
CX35-48C+TDR
SL280UH100NV60C*15.6137.819,700 Btu/hNo210869950
CK40CT-49C-0*+TDR
ML180UH110V60C*15.6137.819,900 Btu/hNo214624398
CK40CT-49C-0*+TDR
SL280UH100NV60C*15.6137.819,900 Btu/hNo214624413
CK40CT-48C-0*+TDR
EL280UH110E60C*15.6137.819,600 Btu/hNo214624346
CK40CT-48C-0*+TDR
EL280UH110E48C*15.6137.819,600 Btu/hNo214624345
CK40CT-48C-0*+TDR
EL280UH110XE60C*15.6137.819,600 Btu/hNo214624347
CK40CT-48C-0*+TDR
ML180UH110V60C*15.6137.819,700 Btu/hNo214624357
CK40CT-48C-0*+TDR
SL280UH080NV60C*15.6137.819,700 Btu/hNo214624369
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-410A 3.5-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
25VNA448A*031*Carrier20.5–21936,200–36,400 Btu/h6
284ANV048*0**B*Bryant20.5–21936,200–36,400 Btu/h6
ASZS60421EA*Amana178.630,600 Btu/h21
ASZS60481EA*Amana178.5–8.631,000 Btu/h21
DZ6VSA421EA*Daikin178.630,600 Btu/h20
DZ6VSA481EA*Daikin178.5–8.631,000 Btu/h20
SP18AZ48AJVCRussell, Sure188.542,000–45,000 Btu/h4
4HP17L42P-**AAC Pro, Concord +4 more15.2–15.67.8–8.319,600–22,000 Btu/h349

All 39 R-410A 3.5-ton units

More Lennox R-410A units

Next step