Outdoor unit · ENERGY STAR data November 12, 2026

EL17XP1-042-230A**: R-410A heat pump

Sold as Lennox. R-410A Ducted split system, 3.5-ton class, in 188 ENERGY STAR certified pairings with 26 indoor unit models.

Refrigerant
R-410A (GWP 2,088)
Rated cooling
41,500 Btu/h
SEER2 range
15.2–15.6
HSPF2 range
7.8–8.3
Heat at 5°F
10,400–22,000 Btu/h
Cold-climate pairings
0 of 188
Compressor
Single stage
First certified
2025-10-27

This is an R-410A unit. New R-410A split systems stopped being made or imported on January 1, 2025. Under EPA's May 2026 rule, a complete system can still be installed only if every component was made or imported before 2025, and a newer R-410A condensing unit must be labeled "For servicing existing equipment only". State rules can be stricter. What that means for a quote.

Series: MERIT ML17XP1 Series, ELITE EL17XP1 Series, Elite EL17XP1 Series. ENERGY STAR partner: Lennox Industries.

Certified indoor matches

Top 30 of 188 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
CBA38MV-042-230*+TDR
—15.6138.320,600 Btu/hNo210293753
CBA27UHE-042-230*+TDR
—15.6138.322,000 Btu/hNo210293752
CRX35-48C-**-*+TDR
ML180DF110E60C*15.6138.321,800 Btu/hNo213257813
CK40DT-48C-0*+TDR
ML180DF110E60C*15.6138.321,800 Btu/hNo214622738
CBK47UHET-042-230-0*
—15.6138.322,000 Btu/hNo214861226
CX35-49C+TDR
SL280UH100NV60C*15.6137.819,900 Btu/hNo210293906
C35-49C+TDR+TXV
SL280UH100NV60C*15.6137.819,900 Btu/hNo210293742
CX35-49C+TDR
ML180UH110V60C*15.6137.819,900 Btu/hNo210293892
C35-49C+TDR+TXV
ML180UH110V60C*15.6137.819,900 Btu/hNo210293728
CK40CT-49C-0*+TDR
ML180UH110V60C*15.6137.819,900 Btu/hNo214622767
CK40CT-49C-0*+TDR
SL280UH100NV60C*15.6137.819,900 Btu/hNo214622781
C35-48C+TDR+TXV
EL280UH110E48C*15.6137.819,600 Btu/hNo215223654
C35-48C+TDR+TXV
EL280UH110E60C*15.6137.819,600 Btu/hNo215223655
C35-48C+TDR+TXV
EL280UH110XE60C*15.6137.819,600 Btu/hNo215223656
C35-48C+TDR+TXV
ML180UH110V60C*15.6137.819,700 Btu/hNo215223659
C35-48C+TDR+TXV
SL280UH080NV60C*15.6137.819,700 Btu/hNo215223666
C35-48C+TDR+TXV
SL280UH100NV60C*15.6137.819,700 Btu/hNo215223669
CHX35-42B-**-*+TDR
EL280UH090E48B*15.6137.819,900 Btu/hNo215223674
CHX35-42B-**-*+TDR
EL280UH090XE48B*15.6137.819,900 Btu/hNo215223675
CX35-48C+TDR
EL280UH110E48C*15.6137.819,600 Btu/hNo215223689
CX35-48C+TDR
EL280UH110E60C*15.6137.819,600 Btu/hNo215223690
CX35-48C+TDR
EL280UH110XE60C*15.6137.819,600 Btu/hNo215223691
CX35-48C+TDR
ML180UH110V60C*15.6137.819,700 Btu/hNo215223694
CX35-48C+TDR
SL280UH080NV60C*15.6137.819,700 Btu/hNo215223701
CX35-48C+TDR
SL280UH100NV60C*15.6137.819,700 Btu/hNo215223704
CK40HT-42B-0*+TDR
EL280UH090E48B*15.6137.819,900 Btu/hNo215223760
CK40HT-42B-0*+TDR
EL280UH090XE48B*15.6137.819,900 Btu/hNo215223761
CK40CT-48C-0*+TDR
EL280UH110E48C*15.6137.819,600 Btu/hNo215223885
CK40CT-48C-0*+TDR
EL280UH110E60C*15.6137.819,600 Btu/hNo215223886
CK40CT-48C-0*+TDR
EL280UH110XE60C*15.6137.819,600 Btu/hNo215223887
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-410A 3.5-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
25VNA448A*031*Carrier20.5–21936,200–36,400 Btu/h6
284ANV048*0**B*Bryant20.5–21936,200–36,400 Btu/h6
ASZS60421EA*Amana178.630,600 Btu/h21
ASZS60481EA*Amana178.5–8.631,000 Btu/h21
DZ6VSA421EA*Daikin178.630,600 Btu/h20
DZ6VSA481EA*Daikin178.5–8.631,000 Btu/h20
SP18AZ48AJVCRussell, Sure188.542,000–45,000 Btu/h4
4HP17L42P-**AAC Pro, Concord +4 more15.2–15.67.8–8.319,600–22,000 Btu/h349

All 39 R-410A 3.5-ton units