Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

GZV7SA6010A*: R-32 heat pump

Sold as Goodman. R-32 Ducted split system, 4.5-ton class, in 35 ENERGY STAR certified pairings with 13 indoor unit models.

Refrigerant
R-32 (GWP 675)
Rated cooling
52,000 Btu/h
SEER2 range
15.2–18
HSPF2 range
8.5–9
Heat at 5°F
45,000–46,000 Btu/h
Cold-climate pairings
35 of 35
Compressor
Continuously variable
First certified
2025-07-03

This unit uses R-32, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-32, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: GZV7SA. ENERGY STAR partner: Daikin Comfort Technologies Manufacturing, L.P..

Certified indoor matches

Top 30 of 35 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
AHVE60DP1300A*
—189.8946,000 Btu/hYes216835221
AHVE60DP0300A*
—189.8946,000 Btu/hYes216835310
CA*EA6030*3A*+MBVK20DP1X00A*
—179.88.846,000 Btu/hYes216835314
CA*EA6030*3A*+MBVK16CP1X00A*
—179.88.846,000 Btu/hYes216835319
CA*EA6030*3A*
G*VT801005C*A*179.88.846,000 Btu/hYes216835342
CA*EA6030*3A*
G*VT800805D*A*179.88.846,000 Btu/hYes216835346
CA*EA6030*3A*
G*VT800805C*A*179.88.846,000 Btu/hYes216835351
CA*EA6030*3A*
G*VS800805CUA*179.88.846,000 Btu/hYes216835360
CAHEA3630C3A*+MBVK16CH*X00A*
—179.88.846,000 Btu/hYes216835372
CA*EA6030*3A*+MBVK20DP0X00A*
—179.88.846,000 Btu/hYes217589480
CA*EA6030*3A*+MBVK16CP0X00A*
—179.88.846,000 Btu/hYes217589482
CA*EA6030*3A*
G*VT960804CNA*16.59.88.846,000 Btu/hYes216835338
CA*EA6030*3A*
G*VM971005CNA*16.59.88.846,000 Btu/hYes216835370
CA*EA6030*3A*
G*VS960805CUA*16.59.88.846,000 Btu/hYes217495909
CA*EA6030*3A*
G*VT961005CNA*16.59.88.546,000 Btu/hYes216835333
CHPEA6030*3A*+MBVK20DP1X00A*
—169.88.545,000 Btu/hYes216835312
CHPEA6030*3A*+MBVK16CP1X00A*
—169.88.545,000 Btu/hYes216835317
CHPEA6030*3A*
G*VT961205DNA*169.88.545,000 Btu/hYes216835321
CA*EA6030*3A*
G*VT961205DNA*169.88.546,000 Btu/hYes216835324
CHPEA6030*3A*
G*VT961005DNA*169.88.545,000 Btu/hYes216835327
CA*EA6030*3A*
G*VT961005DNA*169.88.546,000 Btu/hYes216835329
CHPEA6030*3A*
G*VT801005C*A*169.88.545,000 Btu/hYes216835340
CHPEA6030*3A*
G*VT800805D*A*169.88.545,000 Btu/hYes216835344
CHPEA6030*3A*
G*VT800805C*A*169.88.545,000 Btu/hYes216835349
CHPEA6030*3A*
G*VS800805CUA*169.88.545,000 Btu/hYes216835358
CHPEA6030*3A*
G*VM971205DNA*169.88.545,000 Btu/hYes216835362
CA*EA6030*3A*
G*VM971205DNA*169.88.546,000 Btu/hYes216835365
CHPEA6030*3A*+MBVK20DP0X00A*
—169.88.545,000 Btu/hYes217589479
CHPEA6030*3A*+MBVK16CP0X00A*
—169.88.545,000 Btu/hYes217589481
CHPEA6030*3A*
G*VC961205DNB*169.88.545,000 Btu/hYes217902914
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-32 4.5-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
ACIQ-60-HP321HVAC, ACiQ +2 more18.210.554,000 Btu/h4
TU60W-EDUTOSOT18.2–1910–10.548,000–54,000 Btu/h3
VHP-UCHA-60HDCT-AVillaTherm16.2–179–9.838,500–40,000 Btu/h5
KUSXB601ALG15.2–17.58.5–9.441,000–45,000 Btu/h7
AZV7SA6010A*Amana15.2–188.5–945,000–46,000 Btu/h35
AZV9SA6010A*Amana15.2–188.5–945,000–47,000 Btu/h31
DH7VSA6010A*Daikin15.2–188.5–945,000–46,000 Btu/h35
DH9VSA6010A*Daikin15.2–188.5–945,000–47,000 Btu/h31

All 31 R-32 4.5-ton units

More Goodman R-32 units

Next step