Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

DH9VSA6010A*: R-32 heat pump

Sold as Daikin. R-32 Ducted split system, 4.5-ton class, in 31 ENERGY STAR certified pairings with 9 indoor unit models.

Refrigerant
R-32 (GWP 675)
Rated cooling
52,000 Btu/h
SEER2 range
15.2–18
HSPF2 range
8.5–9
Heat at 5°F
45,000–47,000 Btu/h
Cold-climate pairings
31 of 31
Compressor
Continuously variable
First certified
2026-01-20

This unit uses R-32, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-32, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: DH9VSA. ENERGY STAR partner: Daikin Comfort Technologies Manufacturing, L.P..

Certified indoor matches

Top 30 of 31 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
DFVE60DP1300A*
—1810.5947,000 Btu/hYes217989105
DFVE60DP0300A*
—1810.5947,000 Btu/hYes217989110
CA*EA6030*3A*+MBVK20DP1X00A*
—179.88.846,000 Btu/hYes217989112
CA*EA6030*3A*+MBVK16CP1X00A*
—179.88.846,000 Btu/hYes217989114
CA*EA6030*3A*
D*80TC1005C*A*179.88.846,000 Btu/hYes217989124
CA*EA6030*3A*
D*80TC0805D*A*179.88.846,000 Btu/hYes217989126
CA*EA6030*3A*
D*80TC0805C*A*179.88.846,000 Btu/hYes217989128
CA*EA6030*3A*
D*80SC0805CUA*179.88.846,000 Btu/hYes217989134
CAHEA3630C3A*+MBVK16CH*X00A*
—179.88.846,000 Btu/hYes217989139
CA*EA6030*3A*
D*96TC0804CNA*16.59.88.846,000 Btu/hYes217989122
CA*EA6030*3A*
D*96SC0805CUA*16.59.88.846,000 Btu/hYes217989132
CA*EA6030*3A*
D*97MC1005CNA*16.59.88.846,000 Btu/hYes217989138
CA*EA6030*3A*
D*96TC1005CNA*16.59.88.546,000 Btu/hYes217989120
CHPEA6030*3A*+MBVK20DP1X00A*
—169.88.545,000 Btu/hYes217989111
CHPEA6030*3A*+MBVK16CP1X00A*
—169.88.545,000 Btu/hYes217989113
CHPEA6030*3A*
D*96TC1205DNA*169.88.545,000 Btu/hYes217989115
CA*EA6030*3A*
D*96TC1205DNA*169.88.546,000 Btu/hYes217989116
CHPEA6030*3A*
D*96TC1005DNA*169.88.545,000 Btu/hYes217989117
CA*EA6030*3A*
D*96TC1005DNA*169.88.546,000 Btu/hYes217989118
CHPEA6030*3A*
D*80TC0805D*A*169.88.545,000 Btu/hYes217989125
CHPEA6030*3A*
D*80TC1005C*A*169.88.545,000 Btu/hYes217989123
CHPEA6030*3A*
D*80TC0805C*A*169.88.545,000 Btu/hYes217989127
CHPEA6030*3A*
D*97MC1205DNA*169.88.545,000 Btu/hYes217989135
CA*EA6030*3A*
D*97MC1205DNA*169.88.546,000 Btu/hYes217989136
CHPEA6030*3A*
D*80SC0805CUA*169.88.545,000 Btu/hYes217989133
CA*EA6030*3A*
D*96VC1205DNA*169.88.546,000 Btu/hYes218003033
CHPEA6030*3A*
D*96VC1205DNA*169.88.545,000 Btu/hYes218003032
CHPEA6030*3A*
D*96TC1005CNA*15.59.88.545,000 Btu/hYes217989119
CHPEA6030*3A*
D*96SC0805CUA*15.59.88.545,000 Btu/hYes217989131
CHPEA6030*3A*
D*97MC1005CNA*15.59.88.545,000 Btu/hYes217989137
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-32 4.5-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
ACIQ-60-HP321HVAC, ACiQ +2 more18.210.554,000 Btu/h4
TU60W-EDUTOSOT18.2–1910–10.548,000–54,000 Btu/h3
VHP-UCHA-60HDCT-AVillaTherm16.2–179–9.838,500–40,000 Btu/h5
KUSXB601ALG15.2–17.58.5–9.441,000–45,000 Btu/h7
AZV7SA6010A*Amana15.2–188.5–945,000–46,000 Btu/h35
AZV9SA6010A*Amana15.2–188.5–945,000–47,000 Btu/h31
DH7VSA6010A*Daikin15.2–188.5–945,000–46,000 Btu/h35
GZV7SA6010A*Goodman15.2–188.5–945,000–46,000 Btu/h35

All 31 R-32 4.5-ton units

More Daikin R-32 units

Next step