R-32 4.5-ton heat pumps
31 ENERGY STAR certified R-32 outdoor unit models in the 4.5-ton class from 22 brands, in 240 certified systems. Sorted by best HSPF2 (heating efficiency).
- Outdoor models
- 31
- Best SEER2
- 19.6
- Best HSPF2
- 10.8
- With cold-climate pairings
- 28
| Outdoor unit | Brand | SEER2 | HSPF2 | Heat at 5°F | Cold-climate pairings | Certified pairings |
|---|---|---|---|---|---|---|
VUH60-VA6BA(0) | Samyou | 19.6 | 10.8 | 44,500 Btu/h | 1 | 1 |
VUH60-VA6BA(O) | VINO | 19.6 | 10.8 | 44,500 Btu/h | 1 | 1 |
TU60W-EDU | TOSOT | 18.2–19 | 10–10.5 | 48,000–54,000 Btu/h | 3 | 3 |
ACIQ-60-HP32 | 1HVAC, ACiQ +2 more | 18.2 | 10.5 | 54,000 Btu/h | 4 | 4 |
TU60-32WEDU | TOSOT | 18.2 | 10.5 | 54,000 Btu/h | 1 | 1 |
HP-UA60/O | TOSOT | 18.2 | 10 | 54,000 Btu/h | 1 | 1 |
VHP-UCHA-60HDCT-A | VillaTherm | 16.2–17 | 9–9.8 | 38,500–40,000 Btu/h | 5 | 5 |
MCHA-60HDCTO2 | MDX | 16.2 | 9.8 | 40,000 Btu/h | 1 | 1 |
UCHA-60HDCTRN2 | UTL | 16.2 | 9.8 | 40,000 Btu/h | 1 | 1 |
BNG2Z60SCM | Blueridge | 19 | 9.5 | 40,000 Btu/h | 0 | 1 |
BNG2Z60SCN | Blueridge | 19 | 9.5 | 40,000 Btu/h | 0 | 1 |
TU60-32GDU | TOSOT | 19 | 9.5 | 40,000 Btu/h | 0 | 1 |
H60SDH20XQC | TCL | 17 | 9.5 | 50,000 Btu/h | 1 | 1 |
RV-AHU55S-O | Rovsun | 17 | 9.5 | 50,000 Btu/h | 1 | 1 |
THH55HDI2NAJ0H26 | TCL | 17 | 9.5 | 50,000 Btu/h | 1 | 1 |
TMFS55HDI2NAJ0H26 | Thermoflux | 17 | 9.5 | 50,000 Btu/h | 1 | 1 |
AHU60HPV1BO | AUX | 16.5 | 9.5 | 48,000 Btu/h | 1 | 1 |
GHO60H52ACXL05 | Havells | 16.5 | 9.5 | 48,000 Btu/h | 1 | 1 |
OAH-AHU60K-CH-O | Ortech | 16.5 | 9.5 | 48,000 Btu/h | 1 | 1 |
KUSXB601A | LG | 15.2–17.5 | 8.5–9.4 | 41,000–45,000 Btu/h | 7 | 7 |
AZV7SA6010A* | Amana | 15.2–18 | 8.5–9 | 45,000–46,000 Btu/h | 35 | 35 |
AZV9SA6010A* | Amana | 15.2–18 | 8.5–9 | 45,000–47,000 Btu/h | 31 | 31 |
DH7VSA6010A* | Daikin | 15.2–18 | 8.5–9 | 45,000–46,000 Btu/h | 35 | 35 |
DH9VSA6010A* | Daikin | 15.2–18 | 8.5–9 | 45,000–47,000 Btu/h | 31 | 31 |
GZV7SA6010A* | Goodman | 15.2–18 | 8.5–9 | 45,000–46,000 Btu/h | 35 | 35 |
GZV9SA6010A* | Goodman | 15.2–18 | 8.5–9 | 45,000–47,000 Btu/h | 31 | 31 |
UCHA-60HDCTN2 | UTL | 17 | 9 | 38,500 Btu/h | 1 | 1 |
UCHA-60HDCSN2 | UTL | 16.7 | 9 | 40,000 Btu/h | 2 | 2 |
VHPSD-UCHA-60HDCSN* | VillaTherm | 16.7 | 9 | 40,000 Btu/h | 1 | 1 |
THH55TDI2NAF2H26 | TCL | 17 | 8.5 | 40,000 Btu/h | 1 | 1 |
MOX630-60HFN8-M3F | MDV | 16.2–16.3 | 8.2 | 39,500 Btu/h | 2 | 2 |
Same size, other refrigerants: R-454B (180) · R-410A (65). Nearby sizes: 3-ton · 4-ton.
Size class is based on the median rated cooling capacity of each unit's certified pairings. Ranges show the spread across pairings, because the indoor unit changes the rating. A load calculation by your installer decides the right size.
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.