Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

FRP17AY60AJVC: R-454B heat pump

Sold as Friedrich. R-454B Ducted split system, 4.5-ton class, in 97 ENERGY STAR certified pairings with 3 indoor unit models.

Refrigerant
R-454B (GWP 470)
Rated cooling
56,500 Btu/h
SEER2 range
16–17
HSPF2 range
8.5–9.5
Heat at 5°F
39,500–45,500 Btu/h
Cold-climate pairings
97 of 97
Compressor
Continuously variable
First certified
2026-07-07

This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: F-Series Plus. ENERGY STAR partner: Rheem Sales Company, Inc..

Certified indoor matches

Top 30 of 97 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
TCFY6024STANM
FR802V1505A24UHS1710.59.545,000 Btu/hYes218328387
TCFY6024STANM
FR802V1505A24UHN1710.59.545,000 Btu/hYes218328386
TCFY6024STANM
FR802V1255A24UHS1710.59.545,000 Btu/hYes218328385
TCFY6024STANM
FR802V1255A24UHN1710.59.545,000 Btu/hYes218328384
TCFY6024STANM
FR802V1255A24DZS17109.545,000 Btu/hYes218328383
TCFY6024STANM
FR802V1255A24DZN17109.545,000 Btu/hYes218328382
TCFY6024STANM
FR802V1005A21DZS1710.59.545,000 Btu/hYes218328379
TCFY6024STANM
FR802V1005A21DZN1710.59.545,000 Btu/hYes218328378
TCFY6024STANM
FR801V1505A24UHS1710.59.545,000 Btu/hYes218328373
TCFY6024STANM
FR801V1505A24UHN1710.59.545,000 Btu/hYes218328372
TCFY6024STANM
FR801V1255A24UHS1710.59.545,000 Btu/hYes218328371
TCFY6024STANM
FR801V1255A24UHN1710.59.545,000 Btu/hYes218328370
TCFY6024STANM
FR801V1255A24DZS17109.545,000 Btu/hYes218328369
TCFY6024STANM
FR801V1255A24DZN17109.545,000 Btu/hYes218328368
TCFY6024STANM
FR801V1005A21DZS1710.59.545,000 Btu/hYes218328364
TCFY6024STANM
FR801V1005A21DZN1710.59.545,000 Btu/hYes218328363
RCFY6024STANM
FR802V1505A24UHS1710.59.545,000 Btu/hYes218328127
RCFY6024STANM
FR802V1505A24UHN1710.59.545,000 Btu/hYes218328126
RCFY6024STANM
FR802V1255A24UHS1710.59.545,000 Btu/hYes218328125
RCFY6024STANM
FR802V1255A24UHN1710.59.545,000 Btu/hYes218328124
RCFY6024STANM
FR802V1255A24DZS17109.545,000 Btu/hYes218328123
RCFY6024STANM
FR802V1255A24DZN17109.545,000 Btu/hYes218328122
RCFY6024STANM
FR802V1005A21DZS1710.59.545,000 Btu/hYes218328119
RCFY6024STANM
FR802V1005A21DZN1710.59.545,000 Btu/hYes218328118
RCFY6024STANM
FR801V1505A24UHS1710.59.545,000 Btu/hYes218328113
RCFY6024STANM
FR801V1505A24UHN1710.59.545,000 Btu/hYes218328112
RCFY6024STANM
FR801V1255A24UHS1710.59.545,000 Btu/hYes218328111
RCFY6024STANM
FR801V1255A24UHN1710.59.545,000 Btu/hYes218328110
RCFY6024STANM
FR801V1255A24DZS17109.545,000 Btu/hYes218328109
RCFY6024STANM
FR801V1255A24DZN17109.545,000 Btu/hYes218328108
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-454B 4.5-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
27VNA154A*030*Carrier17–218–10.545,500–54,000 Btu/h155
291VAN054**AA*Bryant17–218–10.545,500–54,000 Btu/h155
MDV-V60WMN10TMidea16–19.58.9–10.142,000–45,000 Btu/h7
BOHA-60RTB-M18SBosch15.5–198–9.831,000–42,000 Btu/h19
MDV-V60WMN10T(A)Midea15.5–198–9.831,000–42,000 Btu/h17
SL22KLV-060-230A**Lennox18.2–21.18.2–9.635,400–45,500 Btu/h33
37MUHAQ60AA3Bryant, Carrier +3 more15.2–17.58.1–9.543,000–54,000 Btu/h33
ACIQ-60-HPDACiQ, 1HVAC15.2–17.58.1–9.541,000–54,000 Btu/h13

All 180 R-454B 4.5-ton units

More Friedrich R-454B units

Next step