Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

4TWV7X48A1: R-410A heat pump

Sold as Trane. R-410A Ducted split system, 4-ton class, in 129 ENERGY STAR certified pairings with 17 indoor unit models.

Refrigerant
R-410A (GWP 2,088)
Rated cooling
46,500 Btu/h
SEER2 range
17–17.1
HSPF2 range
8.1–8.5
Heat at 5°F
27,400–28,800 Btu/h
Cold-climate pairings
0 of 129
Compressor
Continuously variable
First certified
2025-04-09

This is an R-410A unit. New R-410A split systems stopped being made or imported on January 1, 2025. Under EPA's May 2026 rule, a complete system can still be installed only if every component was made or imported before 2025, and a newer R-410A condensing unit must be labeled "For servicing existing equipment only". State rules can be stricter. What that means for a quote.

Series: XV17. ENERGY STAR partner: Trane and American Standard Heating and Air Conditioning.

Certified indoor matches

Top 30 of 129 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
TAMXB0C42V41
—17.111.78.527,800 Btu/hNo212391367
TAMXB0C60V51
—17.1128.527,800 Btu/hNo212391368
TAMXB0C48V41
—17.111.78.528,000 Btu/hNo212391375
4PX*CD60BS3
S9V2C100D5PSB+LRP17.111.78.528,400 Btu/hNo213826605
4PX*CD60BS3
S9V2C100D4VSB+LRP17.111.78.528,400 Btu/hNo213826607
4PX*CD60BS3
S9V2C100D4VSA+LRP17.111.78.528,400 Btu/hNo213826609
4PX*CD60BS3
S9V2C100D5PSC+LRP17.111.78.528,400 Btu/hNo213826611
4PX*CU42BS3
L8V1C100U5VSB+LRP17.111.78.528,800 Btu/hNo213826613
4PX*CU48BS3
L8V1C100U5VSB+LRP17.111.78.528,800 Btu/hNo213826615
4PX*CU48BS3
*UHMC100ACV4+LRP17.111.78.528,600 Btu/hNo213826619
4PX*CU48BS3
*UHMC100CCV4+LRP17.111.78.528,600 Btu/hNo213826617
4PX*CU60BS3
*UHMC100CCV4+LRP17.1128.528,200 Btu/hNo213826623
4PX*CU60BS3
*UHMC100ACV4+LRP17.1128.528,200 Btu/hNo213826621
4PX*CU60BS3
L8V1C100U5VSB+LRP17.1128.528,400 Btu/hNo213826625
4TXCD010DS3
S9V2C100U5PSC+LRP17.111.78.527,600 Btu/hNo213826721
4TXCD010DS3
S9V2C080U5PSB+LRP17.111.78.527,600 Btu/hNo213826723
4PX*DU48BS3
L8V1C100U5VSB+LRP17.111.78.527,800 Btu/hNo213826643
4PX*DU48BS3
*UHMC100CCV4+LRP17.111.78.527,800 Btu/hNo213826645
4PX*DU48BS3
S9V2C100U5PSC+LRP17.111.78.528,000 Btu/hNo213826647
4PX*DU48BS3
*UHMC100ACV4+LRP17.111.78.527,800 Btu/hNo213826651
4PX*DU48BS3
S9V2C100U5PSB+LRP17.111.78.528,000 Btu/hNo213826649
4PX*DU60BS3
S9V2C080U5PSB+LRP17.111.78.527,600 Btu/hNo213826655
4PX*DU60BS3
S9V2C080U5PSC+LRP17.111.78.527,600 Btu/hNo213826653
4PX*DU60BS3
L8V1C100U5VSB+LRP17.1128.527,400 Btu/hNo213826657
4PX*DU60BS3
*UHMD120CCV5+LRP17.1128.528,200 Btu/hNo213826659
4PX*DU60BS3
*UHMD120ACV5+LRP17.1128.528,200 Btu/hNo213826661
4PX*DU60BS3
*UHMC100CCV4+LRP17.1128.527,400 Btu/hNo213826663
4TXCD010DS3
S9V2C080U5PSC+LRP17.111.78.527,600 Btu/hNo213826725
4TXCD010DS3
S9V2C100U4VSA+LRP17.111.78.527,400 Btu/hNo213826727
4TXCD010DS3
S9V2C100U4VSB+LRP17.111.78.527,400 Btu/hNo213826729
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-410A 4-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
38MURAQ48AB3Bryant, Carrier +10 more15.6–15.99.4–9.646,000–46,500 Btu/h20
DLCURAH48ABKAirquest, Arcoaire +13 more15.6–15.99.4–9.646,000–46,500 Btu/h34
MOE30U-48HFN1-M-[X1]MDV, Mits Air +2 more15.6–15.99.4–9.646,000–46,500 Btu/h5
EODA19H-4860AA*Ecoer15.2–19.58.3–9.528,000–38,500 Btu/h34
YOHA2-60AAYISO15.2–19.58.3–9.528,000–38,500 Btu/h34
A-VCD48SA-1Comfort Aire, Comfort-Aire +1 more15.69.446,000 Btu/h5
ACIQ-48-HPB1HVAC, ACiQ +1 more15.69.446,000 Btu/h3
EZ-48-HP1HVAC, Diycool +2 more15.69.446,000 Btu/h4

All 129 R-410A 4-ton units

More Trane R-410A units

Next step