Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

4A6V0X60A1: R-410A heat pump

Sold as American Standard. R-410A Ducted split system, 4.5-ton class, in 86 ENERGY STAR certified pairings with 27 indoor unit models.

Refrigerant
R-410A (GWP 2,088)
Rated cooling
54,000 Btu/h
SEER2 range
19–19.5
HSPF2 range
7.8–8.5
Heat at 5°F
37,000–40,000 Btu/h
Cold-climate pairings
9 of 86
Compressor
Continuously variable
First certified
2025-04-09

This is an R-410A unit. New R-410A split systems stopped being made or imported on January 1, 2025. Under EPA's May 2026 rule, a complete system can still be installed only if every component was made or imported before 2025, and a newer R-410A condensing unit must be labeled "For servicing existing equipment only". State rules can be stricter. What that means for a quote.

Series: PLATINUM 20, XV20I. ENERGY STAR partner: Trane and American Standard Heating and Air Conditioning.

Certified indoor matches

Top 30 of 86 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
TEM8B0C60V51+TDR
—19.5128.537,000 Btu/hNo207820993
TEM8A0C48V41+TDR
—19.5128.537,000 Btu/hNo207709026
4PX*DU60BS3+P0V0D000M50SC+RP
—19.5128.239,000 Btu/hNo207805675
4TXCD010DS3+P0V0D000M50SC+RP
—19.5128.239,000 Btu/hNo207805681
4PX*CU60BS3+P0V0C000M50SD+RP
—19.5128.239,000 Btu/hNo212629894
4PX*DD60BS3+P0V0D000M50SD+RP
—19.5128.239,500 Btu/hNo212629898
4TXCD008DS3+P0V0D000M50SD+RP
—19.5128.239,500 Btu/hNo212629910
4TXCC009DS3+P0V0C000M50SD+RP
—19.5128.239,000 Btu/hNo212629906
4PX*DU60BS3+P0V0D000M50SD+RP
—19.5128.239,000 Btu/hNo212621478
4TXCD010DS3+P0V0D000M50SD+RP
—19.5128.239,000 Btu/hNo212621480
4PX*DU60BS3
S9V2D120U5VSB+RP19.5128.239,500 Btu/hNo214638870
4TXCD010DS3
S9V2D120U5VSB+RP19.5128.239,500 Btu/hNo214638874
4PX*DU60BS3
S9V2D120U5PSC+RP19.5128.238,500 Btu/hNo214639560
4TXCD010DS3
S9V2D120U5PSC+RP19.5128.238,500 Btu/hNo214639574
4PX*DU60BS3
S9V2D120U5VSA+RP19.5128.239,500 Btu/hNo207590162
4TXCD010DS3
S9V2D120U5VSA+RP19.5128.239,500 Btu/hNo207590164
4PX*CU60BS3+P0V0C000M50SC+RP
—19.5128.239,000 Btu/hNo207805672
4TXCD008DS3+P0V0D000M50SC+RP
—19.5128.239,500 Btu/hNo207805679
4PX*DD60BS3+P0V0D000M50SC+RP
—19.5128.239,500 Btu/hNo207805673
4TXCC009DS3+P0V0C000M50SC+RP
—19.5128.239,000 Btu/hNo207805678
4TXCD010DS3
S9V2D120U5PSB+RP19.5128.239,500 Btu/hNo208185424
4PX*DU60BS3
S9V2D120U5PSB+RP19.5128.239,500 Btu/hNo210653077
4TXCD008DS3
S9V2D120U5VSA+RP19.511.78.140,000 Btu/hNo210653083
4TXCD008DS3
S9V2D120U5PSB+RP19.511.78.140,000 Btu/hNo210653082
4PX*CD60BS3+P0V0C000M50SC+RP
—19.512839,500 Btu/hNo207805670
4TXCD010DS3
S8V2D120M5PDA1911.78.239,500 Btu/hNo211081440
4PX*DU60BS3
S8V2D120M5PDA1911.78.239,500 Btu/hNo211081436
4PX*CU60BS3
S8V2C100M5PDA1911.78.240,000 Btu/hYes211081434
4TXCC009DS3
S8V2C100M5PDA1911.78.240,000 Btu/hYes211081438
4TXCD010DS3
S8V2D120M5PCA1911.78.239,500 Btu/hNo210692079
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-410A 4.5-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
38MURAQ60AB3Bryant, Carrier +10 more15.39.448,500 Btu/h15
A-VCD60SA-1Comfort Aire, Comfort-Aire +1 more15.39.448,500 Btu/h5
ACIQ-60HPB1HVAC, ACiQ +1 more15.39.448,500 Btu/h3
DLCURAH60ABKAirquest, Arcoaire +12 more15.39.448,500 Btu/h22
EZ-60-HP1HVAC, Diycool +2 more15.39.448,500 Btu/h4
MOE30U-55HFN1-MMits Air, MDV +2 more15.2–15.39.2–9.446,500–48,500 Btu/h5
4SHP22LX160P-**AAirease, Armstrong Air16–197.8–8.729,600–31,200 Btu/h48
EL22XPV-060-230A**Lennox16–197.8–8.729,600–31,200 Btu/h30

All 65 R-410A 4.5-ton units

More American Standard R-410A units

Next step