Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

SOV48H2BA: R-454B heat pump

Sold as Innovair. R-454B Ducted split system, 4-ton class, in 18 ENERGY STAR certified pairings with 3 indoor unit models.

Refrigerant
R-454B (GWP 470)
Rated cooling
45,000 Btu/h
SEER2 range
15.2–16.5
HSPF2 range
8.1–9
Heat at 5°F
37,000–42,000 Btu/h
Cold-climate pairings
18 of 18
Compressor
Continuously variable
First certified
2025-05-08

This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: SOV Series, SAV Series. ENERGY STAR partner: Innovair Corporation.

Certified indoor matches

Top 18 of 18 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
MMC60H2128B
ML296UH110XV60C16.510.48.339,000 Btu/hYes218859760
MMC60H2128B
ML193UH110XE48C16.210.28.237,000 Btu/hYes218859699
SAV48BDA
—16108.538,000 Btu/hYes215408659
SAV60BDA
—16108.538,000 Btu/hYes218828634
MMC60H2128B
ML193UH090XE48C16108.338,000 Btu/hYes218859692
MMC60H2128B
MGV96U080C4C15.99.98.941,000 Btu/hYes218859539
MMC60H2128B
ML296UH090XV48C15.910.38.239,000 Btu/hYes218859751
MMC60H2128B
ML193DF090XE48C15.910.18.237,000 Btu/hYes218859676
MMC60H2128B
ML196DF090XE48C15.9108.137,000 Btu/hYes218859707
MMC60H2128B
ML296DF090XV60C15.810.28.239,000 Btu/hYes218859745
MMC60H2128B
ML196UH090XE48C15.8108.137,000 Btu/hYes218859724
MMC60H2128B
ML196UH090XE60C15.4108.338,000 Btu/hYes218859733
MMC60H2128B
MGV96U100C5C15.310941,000 Btu/hYes218859546
MMC60H2128B
—15.210940,000 Btu/hYes217284786
MMC60H2128B
C120-M-V15.29.88.942,000 Btu/hYes217618151
MMC60H2128B
C105-M-V15.210.28.741,000 Btu/hYes217618150
MMC60H2128B
ML196UH110XE60C15.210.28.338,000 Btu/hYes218859773
MMC60H2128B
ML193UH110XE60C15.210.18.338,000 Btu/hYes218859765
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-454B 4-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
BOHA-60MTB-M18SBosch16–19.58.1–10.131,000–45,000 Btu/h24
MDV-V48WMN10TMidea16–208.9–10.135,000–41,000 Btu/h7
MDV-V60WMN10T(B)Midea16–19.58.1–10.131,000–45,000 Btu/h22
249VAN048**AA*Bryant15.2–198.5–1036,000–41,500 Btu/h517
27VPA948A*030*Carrier15.2–198.5–1036,000–41,500 Btu/h534
5A6V0X48A1American Standard19.4–20.89.4–1032,600–34,800 Btu/h137
5TWV0X48A1Trane19.4–20.89.4–1032,600–34,800 Btu/h137
EODA19H-4860AB*Ecoer15.2–198.3–1028,000–38,500 Btu/h59

All 274 R-454B 4-ton units

More Innovair R-454B units

Next step

Some links are affiliate links; we may earn a commission at no cost to you. Disclosure.