Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

MOX630-48HFN10-M3X: R-454B heat pump

Sold as MDV. R-454B Ducted split system, 4-ton class, in 41 ENERGY STAR certified pairings with 12 indoor unit models.

Refrigerant
R-454B (GWP 470)
Rated cooling
45,000 Btu/h
SEER2 range
15.2–17.5
HSPF2 range
8.1–9.5
Heat at 5°F
41,000–48,000 Btu/h
Cold-climate pairings
41 of 41
Compressor
Continuously variable
First certified
2025-03-13

This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: MOX Series, MVB Series, MVBM series. ENERGY STAR partner: GD MIDEA AIR-CONDITIONING EQUIPMENT CO., LTD..

Certified indoor matches

Top 30 of 41 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
MVBDM-48HWFN10-WC3
—17.5129.548,000 Btu/hYes214861548
MVBDM-48HWFN10-WC3-D
—17.5129.548,000 Btu/hYes214861614
MVBDM-60HWFN10-WC3
—17.5129.548,000 Btu/hYes215318732
MVBDM-60HWFN10-WC3-D
—17.5129.548,000 Btu/hYes215359331
MVBDM-48HWFN10-WC3-MAS
—17.5129.548,000 Btu/hYes216030942
MVBM-60C28T6N10
S9V2C100D5VS***16.6108.642,000 Btu/hYes217753426
MVBM-60C28T6N10
S9V2C100U5VS***16.6108.642,000 Btu/hYes217753427
MVBM-60C28T6N10
S9V2B080U4VS***16.6108.541,000 Btu/hYes217550352
MVBC-48HWFN10-MD3E
—16.510.59.546,000 Btu/hYes214861547
MVBC-48HWFN10-MD3E-D
—16.510.59.546,000 Btu/hYes214861594
MVBC-60HWFN10-MD3E-D
—16.510.59.546,000 Btu/hYes215359327
MVBC-48HWFPN10-MD3E
—16.510.59.546,000 Btu/hYes215865886
MVBM-60C28T6N10
S9V2C080U5VS***16.5108.542,000 Btu/hYes217753425
MVBM-60C28T6N10
ML296UH110XV60C*16.510.58.241,000 Btu/hYes217754208
MVBM-60C28T6N10
S9X1C080U5PSB**16.410.28.341,000 Btu/hYes217753428
MVBM-60C28T6N10
S9X2C080U5PSB**16.410.28.341,000 Btu/hYes217753505
MVBM-60C28T6N10
ML193UH110XE48B*16.310.68.141,000 Btu/hYes217754201
MVBM-60C28T6N10
ML193UH110XE48C*16.310.68.141,000 Btu/hYes217896573
MVBM-60D28T6N10
S9V2D120D5VS***16.19.88.541,000 Btu/hYes217753431
MVBM-60D28T6N10
S9V2D120U5VS***16.19.88.541,000 Btu/hYes217753432
MVBM-60C28T6N10
RL18100C16MPS116.110.58.242,000 Btu/hYes217753618
MVBM-60C28T6N10
RL18100C20MPS116.110.58.242,000 Btu/hYes217753619
MVBM-60C28T6N10
ML193UH090XE48B*16.110.28.242,000 Btu/hYes217754200
MVBM-60C28T6N10
ML193UH090XE48C*16.110.28.242,000 Btu/hYes217896570
MVBM-60C28T6N10
ML296UH090XV48B*1610.48.141,000 Btu/hYes217754207
MVBM-60C28T6N10
ML296UH090XV48C*1610.48.141,000 Btu/hYes217896580
MVBM-60C28T6N10
ML296DF090XV60C*15.910.38.141,000 Btu/hYes217754206
MVBM-60C28T6N10
RG19100C20MPS115.810.28.342,000 Btu/hYes217753568
MVBM-60C28T6N10
MGV96U100C5C15.510.48.341,000 Btu/hYes217607710
MVBM-60C28T6N10
ML196UH090XE60C*15.510.38.342,000 Btu/hYes217754204
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-454B 4-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
BOHA-60MTB-M18SBosch16–19.58.1–10.131,000–45,000 Btu/h24
MDV-V48WMN10TMidea16–208.9–10.135,000–41,000 Btu/h7
MDV-V60WMN10T(B)Midea16–19.58.1–10.131,000–45,000 Btu/h22
249VAN048**AA*Bryant15.2–198.5–1036,000–41,500 Btu/h517
27VPA948A*030*Carrier15.2–198.5–1036,000–41,500 Btu/h534
5A6V0X48A1American Standard19.4–20.89.4–1032,600–34,800 Btu/h137
5TWV0X48A1Trane19.4–20.89.4–1032,600–34,800 Btu/h137
EODA19H-4860AB*Ecoer15.2–198.3–1028,000–38,500 Btu/h59

All 274 R-454B 4-ton units

More MDV R-454B units

Next step