Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

MLP15AZ24AJ2N: R-410A heat pump

Sold as Mainline. R-410A Ducted split system, 2-ton class, in 13 ENERGY STAR certified pairings with 3 indoor unit models.

Refrigerant
R-410A (GWP 2,088)
Rated cooling
22,800 Btu/h
SEER2 range
15.2–16
HSPF2 range
7.8–8.1
Heat at 5°F
11,800–12,700 Btu/h
Cold-climate pairings
12 of 13
Compressor
Two-stage
First certified
2026-06-03

This is an R-410A unit. New R-410A split systems stopped being made or imported on January 1, 2025. Under EPA's May 2026 rule, a complete system can still be installed only if every component was made or imported before 2025, and a newer R-410A condensing unit must be labeled "For servicing existing equipment only". State rules can be stricter. What that means for a quote.

Series: Elite, CLASSIC PLUS/ACHIEVER PLUS. ENERGY STAR partner: Rheem-Ruud Manufacturing.

Certified indoor matches

Top 13 of 13 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
MLH2VZ2417STANN
—1611.78.112,300 Btu/hYes212507882
TCFZ2417STANM
ML98MV0603A17UPS15.211.78.112,200 Btu/hYes212507873
TCFZ2417STANM
ML98MV0703A17UPS15.211.78.112,200 Btu/hYes212507875
TCFZ2417STANM
ML97MV0703A17DHS15.211.78.112,600 Btu/hYes212507861
TCFZ2417STANM
ML97MV0603A17DHS15.211.78.112,200 Btu/hYes212507860
TCFZ2417STANM
ML951V0603A17M4S15.211.78.112,600 Btu/hYes212507843
TCFZ2417STANM
ML962V0403A17M4S15.211.78.112,600 Btu/hYes212507847
TCFZ2417STANM
ML962V0603A17M4S15.211.78.112,600 Btu/hYes212507849
TCFZ2417STANM
ML962V0703A17M4S15.211.78.112,500 Btu/hYes212507852
TCFZ2417STANM
ML951V0603A17UHU15.211.78.112,700 Btu/hYes212507845
TCFZ2417STANM
ML951V0403A17M4S15.211.78.112,600 Btu/hYes212507838
TCFZ2417STANM
ML951V0403A17UHU15.211.78.112,700 Btu/hYes212507842
MLH2CZ2417STANN
—15.211.77.811,800 Btu/hNo211306303
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-410A 2-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
ACIQ-24-HPB1HVAC, ACiQ +3 more16.1–199.3–10.520,000–24,000 Btu/h23
BZ33-INV24OUT2-JBreeze3316.1–17.59.5–10.520,000–24,000 Btu/h3
HHS-24HD-AMulti MFG17.4–199.3–10.522,600–24,000 Btu/h3
MOD30-24HFN1-MWMDV, Eco-air +4 more16.1–19.49.3–10.520,000–24,000 Btu/h19
SHV24H2R20Innovair16.1–199.3–10.520,000–24,000 Btu/h5
ACIQ-24-EHPB1HVAC, ACiQ +3 more15.7–179.2–10.218,500–19,400 Btu/h15
AZPN/24WDKepler16.1–17.49.5–10.220,000–22,600 Btu/h6
CDH2024C21CanAir16.1–17.49.5–10.220,000–22,600 Btu/h4

All 159 R-410A 2-ton units

More Mainline R-410A units

Next step

Some links are affiliate links; we may earn a commission at no cost to you. Disclosure.