MLP15AZ18AJ2N: R-410A heat pump

Sold as Mainline. R-410A Ducted split system, 1.5-ton class, in 12 ENERGY STAR certified pairings with 3 indoor unit models.

Refrigerant
R-410A (GWP 2,088)
Rated cooling
17,100 Btu/h
SEER2 range
15.2–16
HSPF2 range
7.8–8.1
Heat at 5°F
8,800–9,500 Btu/h
Cold-climate pairings
2 of 12
Compressor
Two-stage
First certified
2026-06-03

This is an R-410A unit. New R-410A split systems stopped being made or imported on January 1, 2025. Under EPA's May 2026 rule, a complete system can still be installed only if every component was made or imported before 2025, and a newer R-410A condensing unit must be labeled "For servicing existing equipment only". State rules can be stricter. What that means for a quote.

Series: Elite. ENERGY STAR partner: Rheem-Ruud Manufacturing.

Certified indoor matches

Top 12 of 12 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
MLH2VZ2417STANN
—1611.78.19,200 Btu/hYes212507881
TCFZ2417STANM
ML962V0703A17M4S15.211.78.19,300 Btu/hYes212507851
MLH2CZ2417STANN
—15.211.77.89,200 Btu/hNo211641663
TCFZ2417STANM
ML97MV0603A17DHS15.211.77.89,000 Btu/hNo212507865
TCFZ2417STANM
ML98MV0603A17UPS15.211.77.88,800 Btu/hNo212507866
TCFZ2417STANM
ML97MV0703A17DHS15.211.77.89,000 Btu/hNo212507868
TCFZ2417STANM
ML98MV0703A17UPS15.211.77.89,100 Btu/hNo212507864
TCFZ2417STANM
ML962V0603A17M4S15.211.77.89,400 Btu/hNo212507840
TCFZ2417STANM
ML962V0403A17M4S15.211.77.89,300 Btu/hNo212507841
TCFZ2417STANM
ML951V0603A17M4S15.211.77.89,400 Btu/hNo212507815
TCFZ2417STANM
ML951V0403A17M4S15.211.77.89,300 Btu/hNo212507812
TCFZ2417STANM
ML951V0403A17UHU15.211.77.89,500 Btu/hNo212507813
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-410A 1.5-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
ACIQ-18-HPB1HVAC, ACiQ +3 more16.1–19.39.3–10.815,000–18,800 Btu/h25
HHS-18HD-AMulti MFG17–19.39.3–10.816,500–18,800 Btu/h3
MOX430U-18HFN1-MMDV, Eco-air +4 more16.1–19.39.3–10.815,000–18,800 Btu/h13
SHV18H2R20Innovair16.1–19.39.3–10.815,000–18,800 Btu/h4
MOD30-20HFN1-MWMDV, Alsetria +1 more16.310.220,000 Btu/h3
38MURAQ18AB3Bryant, Carrier +10 more16.1–189.3–9.515,000–16,500 Btu/h20
A-KCD18SA-1KERR16.1–189.3–9.515,000–16,500 Btu/h3
A-VCD18SA-1Comfort Aire, Comfort-Aire +1 more16.1–189.3–9.515,000–16,500 Btu/h8